IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN 

AUTHORIZED SERVICE PERSON

HANGER BRACKETS & TRAP 

INSTALLATION

1)  Remove hanger bracket fastened to back of cooler by removing one (1) screw.

2)  Mount the hanger bracket and trap as shown in Figure 2.  

NOTE:

  Hanger Bracket MUST be supported securely.  Add fixture support carrier if wall will not provide adequate support.

IMPORTANT:

 

•   6 1/4 in. (159mm) dimension from wall to centerline of trap must be maintained for proper fit.

 • 

 

Anchor hanger securely to wall using all five (5) 1/4 in. dia. mounting holes.

3)  Install straight valve for 3/8” O.D. tube.

INSTALLATION OF COOLER

4)  Hang the cooler on the hanger bracket.  Be certain the hanger bracket is engaged properly in the slots on the cooler 

back as shown in Figure 2.

5)  Loosen the two (2) screws holding the lower front panel at the bottom of cooler base and two (2) screws at the top 

(Use torx bits sold separately)

.  Remove the front panel and set aside.

6)  Connect water inlet line--See Note 4 of General Instructions.

7)  Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of 

the waste line fits into the trap.  Assemble the slip nut and gasket to the trap and tighten securely.

START UP

Also See General Instructions

8)  Stream height is factory set at 45-50 PSI.  If supply pressure varies greatly from this, adjust screw using the access 

hole in the pushbutton (insert screwdriver).  CW adjustment will raise stream and CCW adjustment will lower stream.  

For best adjustment, stream should hit basin approximately 6-1/2” (165mm) from bubbler.

1

Vandal-Resistant Bubbler

Fig. 3

BASIN

Fig.4

Thermostat Installation Detail

Fig. 5

Heater Strip Detail

34

13

35

32

33

36

45

36

WARNING!

This unit is frost resistant down to 0

°

F with no wind. 

Prevailing winds can reduce the ability of the heater element 

to prevent light freezing. If the ambient air temperature will 

drop below 0

°

F, the cooler needs to be drained of all water 

by blowing out all water lines, evaporator (item 12), and the 

drain trap. A heater strip is used to heat the unit and will 

begin to cycle at 40

°

F

 

 +/- 5

°

F.  A check at this temperature 

will ensure the heater is working and the unit is resistant to 

light freezing.

ALSO, MAKE SURE THERE ARE NO PLASTIC OR FLAM-

MABLE COMPONENTS DIRECTLY ABOVE THE HEATER 

STRIP.

Summary of Contents for VRC Series

Page 1: ...Page 1 98957C Rev G 01 19 VRCTL R 8FR 1D VRCTLFRDD C VRC Series Barrier Free Water Coolers INSTALLATION CARE USE MANUAL ...

Page 2: ...n above Other components and rough in are the same as shown 12 41 29 42 1 6 3 See Fig 6 See Fig 3 25 25 45 40 43 7 11 18 23 45 45 9 13 49 45 23 8 14 TL 15 TLR 19 13 45 4 30 42 42 6 6 4 30 42 2 1 46 44 50 50 32 33 34 13 28 38 39 28 16 TL 17 TLR FIG 1 Uses HFC 134A refrigerant Note Danger Electrical shock hazard Disconnect power before servicing unit ...

Page 3: ...86mm 31 7 8 810mm 32 15 16 837mm 39 1 2 1003mm 2 5 8 67mm 8 203mm 13 7 8 351mm 20 3 8 518mm HANGER BRACKET 6 3 4 173mm LEGEND LEYENDA LÉGENDE A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF BY OTHERS 3 IN 76mm MAXIMUM OUT FROM WALL B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 2 O D DRAIN STUB 2 IN OUT FROM WALL C 1 1 2 TRAP NOT FURNISHED D ELECTRICAL SUPP...

Page 4: ...d gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into the trap Assemble the slip nut and gasket to the trap and tighten securely START UP Also See General Instructions 8 Stream height is factory set at 45 50 PSI If supply pressure varies greatly from this adjust screw using the access hole in the pushbutton insert screwdriver CW adjus...

Page 5: ...1 19 VRCTL R 8FR 1D VRCTLFRDD C Fig 6 Refrigerated side shown 30 1 45 8 4 1 25 1 16 TL 17 TLR 31 24 18 45 45 21 22 27 27 27 27 5 26 47 20 48 27 45 45 27 Items 31 24 also used on the LH unit 1 45 Basin 4 50 38 39 28 4 47 45 ...

Page 6: ...LH RH Units Less Refrig PART NO DESCRIPTION REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY NOTE All correspondence pertaining to any of the above water coolers or orders for repair parts MUST include Model No and Serial No of cooler name and part number of replace ment part 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 ...

Reviews: