Elkay smartwell SW1806CR Installation Manual Download Page 3

 

Elkay Manufacturing Company 

Installation Manual (2000000029 Rev. B - 01/22) 

 

Countertop

1.6  Disclaimer

The information contained in this manual is given free of charge. This 

information is based on reliable technical data and is intended for 

people with the technical knowledge to install, use and maintain this 

product at their own discretion and risk. Elkay assumes no responsibility 

for results obtained or damage incurred from the use of this material 

either in whole or in part by the buyer.

1.7  Warranty

This product is covered by a Limited Warranty and Elkay will not be held 

responsible for damage of any kind in connection with the installation of 

the product. 
Refer to the Elkay website http://www.elkay.com/warranty and click on 

DRINKING WATER PRODUCT WARRANTY. 

2. Safety

 

THINK

SAFETY!

Think Safety

Before performing any work, read and 

understand the safety instructions in this 

manual. 

2.1  General

The Elkay Manufacturing Company (Elkay) cannot anticipate every 

possible circumstance that might involve a potential hazard during 

the installation, use or maintenance of this product. The warnings 

and instructions in this manual are, therefore, not all-inclusive. If a 

tool, procedure or work method that is not specifically recommended 

by Elkay is used, you must be satisfied that it is safe for yourself and 

others. You should also make sure that the product will not be damaged 

by the methods you choose. 

Most work-related accidents are caused by failure to observe basic 

safety rules or precautions. An accident can often be avoided by 

recognizing potentially hazardous situations before an accident occurs. 

As you install, use or maintain this product, you must be alert to 

potential hazards. You should also have the necessary training, skills 

and tools to perform any installation or maintenance procedure.

2.2  Safety Alert Symbol and Signal Words

The safety alert symbol is used to alert you to potential 

personal injury hazards. The hazards are identified with 

this safety alert symbol along with a signal word such as 

"WARNING" or "CAUTION".
Signal words help focus your attention on potential 

hazards. The signal words used in this manual are WARNING, 

CAUTION, NOTICE, SAFETY INSTRUCTION and Note. The safety 

messages must be followed to prevent personal injury or death as well 

as prevent product damage.

2.3  Safety Signal Words

WARNING

I

ndicates a potentially 

hazardous situation which, if not 

avoided, could result in death or 

serious injury.

CAUTION

I

ndicates a potentially 

hazardous situation which, if 

not avoided, may result in minor 

or moderate injury. 

NOTICE

Indicates that equipment or property 

damage can result if instructions are 

not followed.

SAFETY

INSTRUCTIONS

Safety instructions (or equivalent) signs 

indicate specific safety-related 

instructions or procedures.

Note: 

 Contains additional information important to a procedure.

2.4  Personal Safety

WARNING

These warnings indicate a 

potentially hazardous situation 

which, if not avoided, could 

result in serious injury or death. Follow all instructions related to 

the installation, use or maintenance of this product (unit).

Personal Protection

   

Be sure to use all personal protective equipment, such as 

safety glasses, sturdy work shoes and cut resistant 

gloves, whenever necessary to ensure your own safety.

   

To avoid eye injury, always wear protective glasses 

with side shields when working near CO

2

 tanks and lines. 

Make sure no one else can be injured by escaping CO

2

 gas 

should a hose or fitting break. 

   

Wear sturdy shoes when unpacking the unit or 

moving it. DO NOT wear open-toed shoes or tennis 

shoes.

   

Wear protective cut resistant gloves during 

installation to protect against sharp edges 

from sheet metal components.

Shock and Electrocution Hazards  

Contact with live electricity can cause serious bodily injury 

and in some cases, death. 

 

In extremely rare cases, the Smartwell Countertop screen 

may briefly reboot during operation as a result of ESD 

(Electrostatic Discharge).  There are no safety concerns 

and no damage resulting to the unit.

DO NOT touch any electrical device with wet hands or 

allow water to come into contact with electrical devices. 

Water will conduct electric current to create a short circuit, 

resulting in injury or death.

WARNING

 

 

DO NOT create a short circuit between a source of 

electricity and a liquid by being in contact with both 

simultaneously.

Pressurized Vessel Hazards 

 

Follow all safety recommendations from the CO

2

 tank 

supplier, including but not limited to: 

   

A carbon dioxide cylinder is a pressure vessel and 

therefore has explosive capabilities

.

   

Due to the possibility of an explosion 

which could result in personal injury or 

property damage, never

 

allow carbon 

dioxide cylinder and its contents to reach a 

temperature exceeding 115° F. 

   

If a CO

2

 gas leak is suspected immediately ventilate 

the contaminated area before attempting to repair the 

leak. People exposed to a high concentration of CO

2

 

gas will experience tremors which are followed rapidly by 

loss of consciousness and suffocation.

   

DO NOT drop a CO

cylinder or stike it with a 

foreign object. Protect cylinders from 

damage. Use a suitable hand truck to move 

cylinders; DO NOT drag, roll, slide or drop.

   

Both filled and empty cylinders should be stored 

indoors in a cool, dry, ventilated location away from 

any source of heat. 

Chain or secure the cylinders in an upright position when in 

use or storage. Store full and empty cylinders separately.

Summary of Contents for smartwell SW1806CR

Page 1: ...Smartwell Countertop Beverage Dispenser with Remote Chiller Model SW1806CR Installation Manual Beverage Dispenser WARNING Read the instructions in this manual and retain for future reference ...

Page 2: ...This manual contains step by step installation instructions for the Elkay Smartwell Countertop beverage dispenser with Remote Chiller A separate Use and Care manual contains the operating instructions The Elkay Smartwell Countertop is a filtered water dispenser that gives users the option to create their own custom beverages using a touch screen on the unit or a mobile device for touchless operati...

Page 3: ...property damage can result if instructions are not followed SAFETY INSTRUCTIONS Safety instructions or equivalent signs indicate specific safety related instructions or procedures Note Contains additional information important to a procedure 2 4 Personal Safety WARNING These warnings indicate a potentially hazardous situation which if not avoided could result in serious injury or death Follow all ...

Page 4: ...e CO2 tank supplier including but not limited to Indirect eye contact with CO2 gas may cause mild irritation Direct eye contact with the liquefied gas can freeze the eye causing permanent eye damage or blindness CO2 gas displaces oxygen Make sure there are no CO2 gas leaks in any part of the Smartwell beverage system Direct contact with the liquefied gas can chill or freeze the skin frostbite Trip...

Page 5: ...standard 120 Volts electric wall receptacle is required The unit must be close enough to socket that the supplied power cord reaches without stress or stretching NOTICE DO NOT connect the unit to a power strip and DO NOT use an extension cord 2 A minimum 20 Amp GFCI outlet on a dedicated circuit is recommended with a minimum current of 5 amps Prior to installation ensure that it is possible to dis...

Page 6: ...ell Cabinet Optional Countertop Dispenser Recommended Hole Dimension Note 18 wide cabinet can store up to a 5 lb CO2 tank 24 wide cabinet can store up to a 20 lb CO2 tank 20 lb CO2 tank shown for reference Compatible with smaller tank sizes Depth of the kitchen cabinet should be at least 22 inches Refer P N 2000000401 for ventilation instruction sheet template Kitchen Cabinet Toe Kick Ventilation ...

Page 7: ...70 1 6 Filter 51299C 1 7 Power Cord 1000004819 1 8 Ethernet Cable 15 feet 1000005025 1 9 Wi Fi Extender 1000005047 1 10 CO2 Bottle Wall Mounting Bracket 1000005199 1 11 50 psi Water Pressure Regulator 1000002467 1 12 Elbow Fitting 3 8 stem x 3 8 tube 70818C 2 13 Filter Head Assembly 1000006192 1 Countertop Dispenser 1 Remote Chiller Boxed Separately 2000000072 1 Pouch Tray 1000005882 1 Drip Tray 1...

Page 8: ...wise to secure b Using 3 8 water tubing make a connection from the water source to the inlet side of the water pressure regulator c With 3 8 water tubing connect the outlet of the water pressure regulator to the shut off valve d With 3 8 water tubing connect the other end of the shut off valve to the IN port of the water filter e Connect a length of 3 8 water tubing to the OUT port of the water fi...

Page 9: ...ng the chiller and enclosure See the separate document Smartwell Chiller Ventilation Instructions which includes templates for drilling the required ventilation holes for the chiller 1 Remove 4 screws from the grate on the back of the chiller 2 Place the chiller duct into position as shown aligning the 4 holes with the previous location of the 4 screws removed from the grate 3 Replace the 4 screws...

Page 10: ...e c Remove the plug from the fill port of the ice bank Insert the 3 8 water line into the water inlet port to fill the ice bank of the Remote Chiller d Note An overfill port is located behind the panel This panel can be removed to access the overflow port but it is not necessary if care is used when filling the tank Slowly fill the ice bank until the water reaches the maximum fill line on the over...

Page 11: ...let port of the Remote Chiller to the still water inlet port of the Countertop unit 2 Connect the 3 8 poly tube from the sparkling water outlet port of Remote Chiller to the CO2 port of the Countertop unit 5 7 Internet 1 Connect an Ethernet cable from your network into the back of the Countertop dispenser or skip to step 2 if connecting via Wi Fi 2 Connect the unit to the supplied Wi Fi extender a...

Page 12: ...Initial Setup 1 Once the Countertop unit main power switch has been flipped to ON a loading screen followed by the Welcome screen will appear 2 Select either Wi Fi or Ethernet connection and press continue a If Wi Fi connection is selected the Wi Fi Netgear screen will open Please follow the manufacturer s directions to set up Note Smartwell uses HTTPS port 443 AMQP port 5671 to allow communicatio...

Page 13: ...installed 5 Depending on whether or not the unit is connected to the Internet one of the following screens will appear The left hand screen will appear if the unit is not connected to the Internet Select the appropriate date and time zone settings then press Save The right hand screen will appear if the unit is connected to the Internet Select the appropriate time zone settings then press Save 6 A...

Page 14: ... they have clicked onto the pump drive holder ensuring it is securely fastened 4 Fully insert the stainless steel nibs into the holes of the manifold taking care to hold by the tubes to avoid contamination Note Check and ensure the flow straightener is snapped properly 5 Select the flavor or enhancement for each slot Choose the MM DD YY from the Best by date slot and select the date Press save 6 S...

Page 15: ...nes 1 Open the water supply valve and purge the trapped air from the water line Note To flush out trapped air allow water to run continuously until the flow is free of air bubbles NOTICE Water pressure that does not meet the minimum pressure requirement of 40 psi can cause damage to the internal components Low pressure may also affect the performance of the unit and the taste of the beverage a Pla...

Page 16: ...ation of flavor in the beverage low medium or high This setting is based on user preferences and the default setting is MEDIUM If more flavor is desired select the HIGH setting d Determine and enter the flow rate for the Still Water and the flow rate for the Sparkling Water 1 Place a large graduated measuring cup at least 32 fl oz under the dispenser nozzle 2 Using a stop watch measure the volume ...

Page 17: ... 3 Unit Diagnostics screen will appear a Press start test to examine the functionality of Motors Water solenoids Temperature Fan Speed Alcove lighting Firewall setting Cloud Communication Internet Speed b Press stop test to complete the unit diagnostics 6 6 Check for Updates The Smartwell unit must be connected to the Internet to receive automatic system updates Follow the next steps to manually c...

Page 18: ...ally check for software updates 3 The unit will search for system updates If your system is not up to date the system will begin automatically updating to the latest software If there is no update required press close to exit ELKAY MANUFACTURING COMPANY 1333 BUTTERFIELD ROAD SUITE 200 DOWNERS GROVE IL 60515 630 574 8484 www elkay com FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1 800 834 4816 ...

Reviews: