98557C (Rev. J - 8/14)

EZWSMD*1A     EZWSM8*1A     EZWSM8*2A     LZWSMD*1A     LZWSM8*1A     LZWSM8*2A

Installation/Care/Use Manual

EZH20 In Wall Bottle Filling Station

To assure you install this model easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave
these instructions inside the fountain for future reference.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.  WE SUGGEST THAT THE BOTTLE FILLER BE PROTECTED BY A GROUND
FAULT CIRCUIT INTERRUPTER (GFCI)

FIG. 2

FIG. 1

Installer

NOTE: WATER FLOW

            DIRECTION

BUILDING WATER
            INLET

    SERVICE STOP
(NOT FURNISHED)

1/4" O.D. TUBE
WATER INLET
TO COOLER

3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY

                           LZWSM8*               LZWSMD*                LZWSM8P*           LZWSMDP*
                           EZWSM8*               EZWSMD*                EZWSM8P*           EZWSMDP*

Summary of Contents for LZWSM8K

Page 1: ...WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTOAFOUNTAIN CREATINGAN ELECTROLYSIS WHICH CAUS...

Page 2: ...98557C Rev J 8 14 Page 2 EZWSMD 1A EZWSM8 1A EZWSM8 2A LZWSMD 1A LZWSM8 1A LZWSM8 2A FIG 3 LZWSM8 LZWSMD EZWSM8 EZWSMD ROUGH IN...

Page 3: ...Page 3 98557C Rev J 8 14 EZWSMD 1A EZWSM8 1A EZWSM8 2A LZWSMD 1A LZWSM8 1A LZWSM8 2A LZWSM8P LZWSMDP EZWSM8P EZWSMDP ROUGH IN FIG 4...

Page 4: ...er supply valve and union not provided Turn on the water supply and flush the line thoroughly 4b Make water supply connections for Non Fltered units Install a shut off valve and union connection to bu...

Page 5: ...Bottle Filler the LCD Bottle Counter should illuminate 15 Verify proper dispensing by placing cup hand or any opaque object in front of sensor area and verify water dispenses Note the first initial d...

Page 6: ...green LED should now be illuminated indicating that the visual filter monitor has been reset SETTING RANGE OF THE IR SENSOR 1 Depress the program button for approximately 2 seconds until the display c...

Page 7: ...play will go back to bottle counter and be in run mode 6 Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed SETTING UNIT TYPE 1 Depress the program button...

Page 8: ...ed allow approximately 4 seconds to pass and then the display will go back to bottle counter and be in run mode 6 Test bottle filler by placing bottle or hand in front of sensor to make sure water is...

Page 9: ...fault back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit...

Page 10: ...ea Fig 8 LISTE DES PI CES DU FILTRE Voir Fig 8 1 2 3 4 5 6 7 WATER FILTER EXPLODED VIEW FIG 8 PRINTED IN U S A IMPRESO EN LOS E E U U IMPRIM AUX U FORPARTS CONTACTYOURLOCALDISTRIBUTORORCALL1 800 834 4...

Reviews: