Elkay LZSDWSS2K Installation And Use Manual Download Page 2

Page 2

1000002684  (Rev. C - 07/19)

EZS8WS_2G, LZS8WS_2G, LZSDWS_2G

Installation

For correct and safe installation, please read these instructions completely.

     •     All Installation work must be performed by an authorized service personnel.

     •     Disconnect electrical supply serving the Installation area to reduce risk of electrocution.

     •     Unit not suitable for installations where water jets could be used. 

DANGER

WARNING

     •     Shut off water supply serving the Installation area to reduce risk of water damage.

     •     Ensure proper ventilation by maintaining clearance from cabinet louvers to wall on each side of Cooler as specified in Rough-In.

     •     Never wire compressor directly to electrical supply.

     •     Thoroughly flush all water lines and fittings of all foreign matter before connecting to Cooler.

     •     Warranty is void if Installation is not made in accordance with current Manufacturing instructions.

CAUTION

     •     Hose-sets are not to be used for connecting to water mains.

     •     If inlet pressure is above 100 psig (0.69 MPa), a pressure regulator must be installed in water supply line. Any damage caused by

           reason of connecting this product to water supply line pressure outside it’s rated pressure, is not covered by warranty.

     •     Tools/Items required but not provided.

                 o       Water Shut-off Valve with 3/8” (9.5mm) compression outlet.

                 o       Waste Trap (non-metallic)

                 o       Safety Glasses

                 o       Protective Gloves

                 o       Hex drives.

                 o       Fasteners for wall type.

Installation: Cooler Mounting

  1. Remove Hanger Bracket fastened to back of cooler by removing one (1) screw.

  2. Mount Hanger Bracket as shown in Figure 1.

   •     NOTE: Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor  hanger

  securely to wall using all six (6) 9/32” (7mm) diameter mounting holes.

   •     IMPORTANT: 5-7/8 inches (150mm) dimension from wall to centerline of trap must be maintained for proper fit.

  3. Hang Cooler on the Hanger Bracket. Be certain the Hanger Bracket is engaged properly in the slots on the cooler back as shown in Figure 1,

  4. Remove the four (4) screws holding the lower front panel at the bottom of cooler. Remove the front panel by pulling straight down and set aside.

Installation: Water Line connection

  1. Ensure Mains Water Supply has Water Shut-off Valve with 3/8” (9.5mm) compression outlet.

  2. Connect loose end of supplied 3/8” (9.5mm) unplated copper tube to Water Shut-off Valve. Other end of tube should be connected to

      inlet of Filter head. If not connected, simply insert into inlet fitting on Filter head until positive stop – approximately ¾” (19mm). Then tighten

      locknut handtight to seal.

   •     NOTE: If 3/8” (9.5mm) copper tube must be cut for proper fit, remove all burrs from the outside of tube and re-flush before use.

  3. Install filter cartridge.  Remove filter from carton, remove protective cap, and attach filter to filter head by firmly inserting into head and rotating  

  filter clockwise.

   •     IMPORTANT:  DO NOT TURN ON WATER BEFORE INSTALLING BOTTLE FILLER

Installation: Electrical connection

  1. Rotate fan to insure proper clearance and free fan action.

  2. Connect modular (C-13) end of International Power Cord Set (sold

      separately) into Power Inlet on Cooler and ensure plug-end reaches

      electrical outlet. Do not plug into electrical outlet!

230Vac, 50Hz Wiring Diagram

Installation: Waste Line connection

  1. Install waste trap. Remove the slip nut and gasket from the waste trap and

  install them on the cooler waste line making sure that the end of the waste

  line fits into the waste trap. Assemble the slip nut and gasket to the waste 

  trap and tighten securely.

   •     IMPORTANT: If it is necessary to cut the drain, loosen the screw at the black  

      rubber boot and remove tube, check for leaks after reassembly.

  2. It is recommended that the waste trap be insulated to avoid excessive conden-

  sation due to chilled water running through the waste trap.

  3. Turn on building water supply and open Water Shut-off Valve. Check all con-

  nections for leaks and correct any found.

PURPLE TO

BOTTLE FILLER

1

C

S

FAN

1

W

HT

5
2

6
3

M

3

2

GND

SM

OO

TH

RI

BB

ED

RELAY

O

VERL

O

AD

COLD

CONTROL

SOLENOID

VALVE

SH

O

RT 

W

HITE LEAD 

FR

OM

 P

OW

ER C

O

RD

T

O

 "L" TER

M

INAL 

O

N P

OW

ER INLET

T

O

 "N" TER

M

INAL 

O

N

P

OW

ER INLET

T

O

 "GR

O

UND" TER

M

INAL

O

N P

OW

ER INLET

GR

EE

- G

RN

D

26

Summary of Contents for LZSDWSS2K

Page 1: ...fter installation keep these instructions in a safe location for future reference Electric supply must be identical in voltage cycle and phase to that specified on nameplate Electrical supply must have Ground Fault Circuit Interrupter GFCI protection A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules This is to allow ele...

Page 2: ... 1 4 Remove the four 4 screws holding the lower front panel at the bottom of cooler Remove the front panel by pulling straight down and set aside Installation Water Line connection 1 Ensure Mains Water Supply has Water Shut off Valve with 3 8 9 5mm compression outlet 2 Connect loose end of supplied 3 8 9 5mm unplated copper tube to Water Shut off Valve Other end of tube should be connected to inle...

Page 3: ...gasket remove this insulation from the 3 8 tube but do not discard Feed the waterline through the hole on top of water cooler NOTE To prevent scratching the basin place a towel or soft cloth over the entire basin when working above it 1 2 5 3 4 7 6 8 Figure 2 Figure 3 Figure 4 Figure 5 Bracket Screws F E A B 7 16 X 3 4 OBROUND 11mm X19mm HOLES 6 C D E 9 32 O HOLES 7mm 12 FINISHED FLOOR L C 7 178mm...

Page 4: ...t plug end of International Cord Sets from the Cooler and Bottle Filler into electrical outlet Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the ON position 12 13 14 16 15 18 17 21 20 19 Once power is applied to Bottle Filler the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter Verify proper dispensing by placing cup ha...

Page 5: ... the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST ...

Page 6: ...nly be cleaned with mild soap and water or Windex glass cleaner and a clean soft cloth Use of harsh chemicals or petroleum based or abrasive cleaners will void the warranty 2 Bubbler Mineral deposits on the orifice can cause water flow to spurt or not regulate Mineral deposits may be removed from the orifice with a small round file not over 1 8 3 mm diameter or small diameter wire CAUTION DO NOT f...

Page 7: ... quick connect fitting see above When installing replacement bubbler and pedestal tighten locknut only to hold parts snug in position Do Not Overtighten After servicing replace the lower front panel and four 4 screws 3 Switches Behind the Push Bar The regulator in an EZ cooler is always held fully open by the use of a single regulator nut Water is not dispensed until the pushbar is depressed to ac...

Page 8: ...2 1000001602 1000004564 1000001812 36004C 97446C 36300C 27416C 27413C See Filter Table 36066C 36067C 28030C 35826C Description Hanger Bracket Basin Stainless Steel Wiring Front Side Push Bar Compr Service Pak 230V 50Hz Polytube Cut To Length Assy Shroud Upper Front Side Push Drier Kit Drain Replacement EZ BF Brckt Tube Ftg Clamp In Line Strainer Kit Solenoid Valve Regulator Assy Kit Flexi Bubbler ...

Reviews: