background image

Page 5

1000004301 (Rev. D - 07/19)

LZS8WS_2FWR, LZWSR_2CWR

Service

Continued from page 4:

2)  

When the display changes to “SETTINGS”, depress the button again.  

      The display will change to show

     

  “RNG SET” -  Range set for IR sensor.

       “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       “FLT SIZE” - Select filter capacity

       “RST BCNT” - Reset bottle count

3)  

When display shows “UNIT TYPE” push program button once the

    display will show current value. 

 

Can be REFRIG or NON-RFRG

4) Push button once to change value. Once value is  

  selected the           

    display will show the new value. 

 

(Can be REFRIG or NON-RFRG)  

     

“REFRIG“ - stands for refrigerated product. In this setting the flow  

    rate is estimated at 1.0 gallon per minute.

     

“NON-RFRG“ - stands for nonrefrigerated product. In this setting the  

    flow rate is estimated at 1.5 gallons per minute.  Both “REFRIG“ and 

    “NON-RFRG“ simulate 

  

1 bottle equal to 20 oz.

5)  

Allow approximately 4 seconds to pass and the display will return to    

    bottle counter and be in run mode.

    

 RESETTING BOTTLE COUNT

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll

    through two messages:

      

“RST FLTR” – Reset Filter Status LED

      

“SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll  

    through the two messages above for three cycles and then default  

    back to bottle count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button  

    again.  The display will change to show:

     

 “RNG SET”-  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       

“FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

    If the button is not pushed again the display will scroll through the 

    four messages above for three cycles and return to run mode.

3)  

When display shows “RST BCNT” push program button once the

    display will show current value, e.g. “0033183”.

4) Once display shows current value push the program button once 

    more to reset back to 0. The display will show BTLCT = 0 for ap

    proximately 2 seconds and then return to run mode showing 

    00000000 bottles. 

 

NOTE: Once the bottle count is reset to zero there is no way to 

  return to the previous bottle count.

5)  Testing the bottle counter:

     REFRIG units: Place bottle or hand in front of sensor for 

     approximately 9 seconds to see bottle counter count 00000001, 

     (This is based on filling a 20 oz. bottle).

     NON-RFRG units: Place bottle or hand in front of sensor for 

   approximately 6 seconds to see bottle counter count 00000001,

     (This is based on filling a 20 oz bottle).

    

 SETTING FILTER CAPACITY

1) Depress the program button for approximately 2 seconds until the

     display changes then release. The display will

 change and scroll 

     through two messages:

     

“RST FLTR” – Reset Filter Status LED

     

“SETTINGS” – System Settings Sub Menu

     If the program button is not pushed again the display will scroll 

     through the two messages above for three cycles and then default 

     back to bottle count and be back in run mode.

2)  When the display changes to “SETTINGS”, depress the button 

     again.  The display will change to show:

     

 “RNG SET“-  Range set for IR sensor.

      “UNIT TYP“ - Type of unit (REFRIG or NON-RFRG)

      

 “FLT SIZE” - Select filter capacity

      “RST BCNT“ - Reset bottle count

    If the button is not pushed again the display will scroll through the 

     four messages above for three cycles and return to run mode.

3)  

When display shows “FLT SIZE” push program button once. The 

     display will show current value. Can be 3000GAL or 6000GAL.

4)  Push program button again to display the desired “FLT SIZE”. 

5)  Allow approximately 4 seconds to pass and the display will return to 

     bottle counter and be in run mode.

• 

Safety Glasses

•  Protective gloves
• 

Hex drives

Service: Adjustments

1.  Temperature Control

: Factory set for 50ºF ± 5º (10ºC ± 5º) water under normal conditions. To adjust water temperature, turn screw clockwise 

for colder, counter clockwise for warmer.

2. 

Water Stream Height: Stream height is factory set at 35 psig (0.24 MPa).  If supply pressure varies greatly from this, adjust screw using the 

access hole in the pushbutton (insert flathead screwdriver).  Clockwise adjustment will raise stream and counter-clockwise adjustment willlower 

stream height.  For best adjustment, stream should hit basin approximately 6.5” (165mm) from bubbler.  

3. 

Water coming out of Bubbler continuously: When this occurs at the end of the compressor cycle, turn the cold control warmer (counterclockwise) 

¼ turn.

Service: Inspection/Cleaning

• 

Inspect Bottle Filler and Cooler twice each year for proper operation and performance.

• 

Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices.

For proper and safe servicing, please read these instructions completely.

DANGER

• 

All Service and Maintenance must be performed by an authorized service personnel. 

• 

Disconnect electrical supply to the unit before any service work to reduce risk of electrocution. 

• 

Shut off water supply serving the unit before any service work to reduce risk of water damage.

CAUTION

•  To prevent scratching the basin, place a towel or soft cloth over the entire basin when working above it.
• 

Tools/Items required but not provided, for Servicing:

1.  Cleaning

: Warm, soapy water or mild household cleaning products can be used to clean the exterior panels. Extra caution should be used         to 

clean the mirror finished stainless steel panels. They can be easily scratched and should only be cleaned with mild soap and water or         Windex 

glass cleaner and a clean, soft cloth. Use of harsh chemicals or petroleum based or abrasive cleaners will void the warranty.

Summary of Contents for LZS8WSS2KWR

Page 1: ...ese instructions in a safe location for future reference Electric supply must be identical in voltage cycle and phase to that specified on nameplate Electrical supply must have Ground Fault Circuit In...

Page 2: ...Shut off Valve with 3 8 9 5mm compression outlet 2 Connect loose end of supplied 3 8 9 5mm unplated copper tube to Water Shut off Valve Other end of tube should be connected to inlet of Filter head I...

Page 3: ...ST be supported securely Add fixture support carrier if wall will not provide adequate support 4 Install wall mounting plate to wall using six 6 7 16 oval mounting holes mounting bolts not included Se...

Page 4: ...down and restarted The chiller if present does not need to be shut down and restarted 2 The units lower panel must be open to access the power cord and wall outlet 3 Shut down the unit by unplugging...

Page 5: ...gh two messages RST FLTR Reset Filter Status LED SETTINGS System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and...

Page 6: ...8926C 1000004312 Description Filter Assy 3000 Gal Kit Filter Head Fitting Includes John Guest Fittings Assy Filter Bracket includes Filter Head Mounting Bracket John Guest Fittings Screws B C A SIMPLY...

Page 7: ...001602 36287C 1000001812 36004C 27416C 27413C See Filter Table 36066C 1000004789 35826C Description Hanger Bracket Basin Stainless Steel Wiring Front Side Push Bar Compr Service Pak 230V 50Hz Polytube...

Reviews: