Page 5
1000004301 (Rev. D - 07/19)
LZS8WS_2FWR, LZWSR_2CWR
Service
Continued from page 4:
2)
When the display changes to “SETTINGS”, depress the button again.
The display will change to show
“RNG SET” - Range set for IR sensor.
“UNIT TYP” - Type of unit (REFRIG or NON-RFRG)
“FLT SIZE” - Select filter capacity
“RST BCNT” - Reset bottle count
3)
When display shows “UNIT TYPE” push program button once the
display will show current value.
Can be REFRIG or NON-RFRG
4) Push button once to change value. Once value is
selected the
display will show the new value.
(Can be REFRIG or NON-RFRG)
“REFRIG“ - stands for refrigerated product. In this setting the flow
rate is estimated at 1.0 gallon per minute.
“NON-RFRG“ - stands for nonrefrigerated product. In this setting the
flow rate is estimated at 1.5 gallons per minute. Both “REFRIG“ and
“NON-RFRG“ simulate
1 bottle equal to 20 oz.
5)
Allow approximately 4 seconds to pass and the display will return to
bottle counter and be in run mode.
RESETTING BOTTLE COUNT
1) Depress the program button for approximately 2 seconds until the
display changes then release. The display will change and scroll
through two messages:
“RST FLTR” – Reset Filter Status LED
“SETTINGS” – System Settings Sub Menu
If the program button is not pushed again the display will scroll
through the two messages above for three cycles and then default
back to bottle count and be back in run mode.
2) When the display changes to “SETTINGS”, depress the button
again. The display will change to show:
“RNG SET”- Range set for IR sensor.
“UNIT TYP” - Type of unit (REFRIG or NON-RFRG)
“FLT SIZE” - Select filter capacity
“RST BCNT” - Reset bottle count
If the button is not pushed again the display will scroll through the
four messages above for three cycles and return to run mode.
3)
When display shows “RST BCNT” push program button once the
display will show current value, e.g. “0033183”.
4) Once display shows current value push the program button once
more to reset back to 0. The display will show BTLCT = 0 for ap
proximately 2 seconds and then return to run mode showing
00000000 bottles.
NOTE: Once the bottle count is reset to zero there is no way to
return to the previous bottle count.
5) Testing the bottle counter:
REFRIG units: Place bottle or hand in front of sensor for
approximately 9 seconds to see bottle counter count 00000001,
(This is based on filling a 20 oz. bottle).
NON-RFRG units: Place bottle or hand in front of sensor for
approximately 6 seconds to see bottle counter count 00000001,
(This is based on filling a 20 oz bottle).
SETTING FILTER CAPACITY
1) Depress the program button for approximately 2 seconds until the
display changes then release. The display will
change and scroll
through two messages:
“RST FLTR” – Reset Filter Status LED
“SETTINGS” – System Settings Sub Menu
If the program button is not pushed again the display will scroll
through the two messages above for three cycles and then default
back to bottle count and be back in run mode.
2) When the display changes to “SETTINGS”, depress the button
again. The display will change to show:
“RNG SET“- Range set for IR sensor.
“UNIT TYP“ - Type of unit (REFRIG or NON-RFRG)
“FLT SIZE” - Select filter capacity
“RST BCNT“ - Reset bottle count
If the button is not pushed again the display will scroll through the
four messages above for three cycles and return to run mode.
3)
When display shows “FLT SIZE” push program button once. The
display will show current value. Can be 3000GAL or 6000GAL.
4) Push program button again to display the desired “FLT SIZE”.
5) Allow approximately 4 seconds to pass and the display will return to
bottle counter and be in run mode.
•
Safety Glasses
• Protective gloves
•
Hex drives
Service: Adjustments
1. Temperature Control
: Factory set for 50ºF ± 5º (10ºC ± 5º) water under normal conditions. To adjust water temperature, turn screw clockwise
for colder, counter clockwise for warmer.
2.
Water Stream Height: Stream height is factory set at 35 psig (0.24 MPa). If supply pressure varies greatly from this, adjust screw using the
access hole in the pushbutton (insert flathead screwdriver). Clockwise adjustment will raise stream and counter-clockwise adjustment willlower
stream height. For best adjustment, stream should hit basin approximately 6.5” (165mm) from bubbler.
3.
Water coming out of Bubbler continuously: When this occurs at the end of the compressor cycle, turn the cold control warmer (counterclockwise)
¼ turn.
Service: Inspection/Cleaning
•
Inspect Bottle Filler and Cooler twice each year for proper operation and performance.
•
Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices.
For proper and safe servicing, please read these instructions completely.
DANGER
•
All Service and Maintenance must be performed by an authorized service personnel.
•
Disconnect electrical supply to the unit before any service work to reduce risk of electrocution.
•
Shut off water supply serving the unit before any service work to reduce risk of water damage.
CAUTION
• To prevent scratching the basin, place a towel or soft cloth over the entire basin when working above it.
•
Tools/Items required but not provided, for Servicing:
1. Cleaning
: Warm, soapy water or mild household cleaning products can be used to clean the exterior panels. Extra caution should be used to
clean the mirror finished stainless steel panels. They can be easily scratched and should only be cleaned with mild soap and water or Windex
glass cleaner and a clean, soft cloth. Use of harsh chemicals or petroleum based or abrasive cleaners will void the warranty.