Elkay LZO Series Installation & User Manual Download Page 7

Page 7

2000000557 (Rev. B - 06/22)

LZO8WSN_2A

Service: Inspection/Replacement

1.     

Lower Front Panel and Upper Shroud: To access the refrigeration system and plumbing connections, remove four screws from bottom of           

        cooler to remove the lower shroud. To remove the upper shroud for access to the sensors, regulator, solenoid valve or other  

        components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower  

        edge of upper shroud, unplug two wires and water tube.

2.     Bubbler

: To remove the bubbler, first disconnect the power supply. The underside of the bubbler can be reached through the access panel  

        (Item 25, Fig 11) on the underside of the upper shroud. Remove the access panel by removing the retaining screw. 

 

        To remove the bubbler, loosen locknut from the underside of the bubbler and remove the tubing from the quick connect fitting per the 

 

        Operation Of Quick Connect Fittings section in the General Instructions. After servicing, replace the access panel and retaining screw.

Replacement Parts: WaterSentry Filter Parts List

Item No.

1

2

Part No.

51300C

0000000746

Description

Filter Assy - 3000 Gallon

Assy-Filter & Bracket includes

      Fltr Head/Mtg Bkt/

     John Guest Ftgs/Screws

11

Basin

Locknut

1

WATER FILTER EXPLODED VIEW

• 

Inspect Bottle Filler and Cooler twice each year for proper operation and performance.

• 

Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and 

reassembly and return to service practices.

Figure 9

Figure 10

Figure 8

2

3/8” 

Water

Inlet

11

NOTE: When installing replacement bubbler and pedestal, tighten  

         nut only to hold parts snug in position. Do Not Overtighten.

Summary of Contents for LZO Series

Page 1: ...ctions and safety precautions in this manual can result in serious injury or death After installation keep these instructions in a safe location for future reference Electric supply must be identical...

Page 2: ...it is necessary to cut the drain loosen the screw at the black rubber boot and remove tube check for leaks after re assembly Installation Water Line connection 1 Ensure Mains Water Supply has Water Sh...

Page 3: ...nplated copper tube B Recommended Location for Waste Outlet 1 1 4 19mm O D drain C 1 1 4 19mm Trap not furnished D Unit equipped with IEC C14 socket Cord not provided Electrical outlet per local code...

Page 4: ...er shroud Replace all four screws previously removed 6 Once unit has been inspected for leaks and any leaks found corrected plug Bottle Filler and unit into wall Be sure to reinstall fuse to the circu...

Page 5: ...t back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REF...

Page 6: ...n this cooler is factory pre set for a visual range of 36 inches 914 mm If actual range varies greatly from this or a different setting is desired follow the range adjustment procedure below Using a s...

Page 7: ...g the retaining screw To remove the bubbler loosen locknut from the underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect Fittings section in...

Page 8: ...339 40319C 1100000002 2000000621 Hanger Bracket Basin Stainless Steel Sensor EE Compressor Serv Pack Tubing Poly Cut To Length Assy Shroud Upper Front Side Push Drier Kit Drain Replacement EZ Brkt Tub...

Page 9: ...d Suite 200 Downers Grove IL 60515 U S A 630 574 8484 www elkay com Figure 12 23 21 1 8 14 25 19 24 5 See Figure 9 Figure 11 Sensor Eye Adjustment screw 18 2 See Figure 12 19 13 10 19 17 9 19 20 15 7...