Elkay LZO Series Installation & User Manual Download Page 3

Page 3

2000000557 (Rev. B - 06/22)

LZO8WSN_2A

Figure 1

F

A

C

L

C

E

B
E

D

17-7/8"

(454mm)

7"

(178mm)

7"

(178mm)

6-3/8"

(162mm)

6-3/8"

(162mm)

15"

(381mm)

7/16" X 3/4"

(11mm X 19mm)

OBROUND 

HOLES (6)

ACTIVATION

SENSOR

Ø 9/32" HOLES

(7mm)

(12)

2"

(51mm)

2"

(51mm)

2-7/8"

(73mm)

FINISHED 

FLOOR

2"

(51mm)

51-9/16"

(1310mm)

38-1/2"

(979mm)

28-13/16"

(732mm)

21-7/8"

(556mm)

19"

(483mm)

17-7/16"

(443mm)

7"

(178mm)

7"

(178mm)

2"

(51mm)

3-7/8"

(98mm)

5-3/4"

(146mm)

32-7/8"

(835mm)

ORIFICE

HEIGHT

31-5/16"

(796mm)

RIM

HEIGHT

5-7/8"

(150mm)

2"

(51mm)

3"

(77mm)

12-1/2"

(318mm)

27"

(686mm)

ADA

REQUIREMENT

HANGER

BRACKET

8-1/16"

(205mm)

19"

(483mm)

3-9/16"

(90mm)

18-7/8"

(479mm)

28-13/16"

(732mm)

13-15/16"

(354mm)

*ADA REQUIREMENT

REDUCE HEIGHT BY 3” (76MM) INCHES FOR INSTALLATION OF CHILDREN’S ACCESSIBLE COOLER

A = Recommended Water Supply Location. Shut Off Valve (not furnished) to accept 3/8” (10mm) O.D. unplated copper tube.

B = Recommended Location for Waste Outlet 1-1/4” (19mm) O.D. drain.

C = 1-1/4” (19mm) Trap not furnished**

D = Unit equipped with IEC C14 socket. Cord not provided. Electrical outlet per local code.

E = Insure proper ventilation by maintaining 6” (152mm) (Min.) clearance from cabinet louvers to wall.

F = 7/16” (11mm) bolt holes for fastening unit to wall.

**New installations must use Ground Fault Circuit Interrupter (GFCI)

Installation: Waste Line connection

1.  Install waste trap. Remove the slip nut and gasket from the waste trap and install them on the cooler waste line making sure that the end of 

the waste line fits into the waste trap. Assemble the slip nut and gasket to the waste trap and tighten securely. 

 

• 

IMPORTANT:

 If it is necessary to cut the drain, loosen the screw at the black rubber boot and remove tube, check for leaks after reassembly.

2. 

It is recommended that the waste trap be insulated to avoid excessive condensation due to chilled water running through the waste trap.

Summary of Contents for LZO Series

Page 1: ...ctions and safety precautions in this manual can result in serious injury or death After installation keep these instructions in a safe location for future reference Electric supply must be identical...

Page 2: ...it is necessary to cut the drain loosen the screw at the black rubber boot and remove tube check for leaks after re assembly Installation Water Line connection 1 Ensure Mains Water Supply has Water Sh...

Page 3: ...nplated copper tube B Recommended Location for Waste Outlet 1 1 4 19mm O D drain C 1 1 4 19mm Trap not furnished D Unit equipped with IEC C14 socket Cord not provided Electrical outlet per local code...

Page 4: ...er shroud Replace all four screws previously removed 6 Once unit has been inspected for leaks and any leaks found corrected plug Bottle Filler and unit into wall Be sure to reinstall fuse to the circu...

Page 5: ...t back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REF...

Page 6: ...n this cooler is factory pre set for a visual range of 36 inches 914 mm If actual range varies greatly from this or a different setting is desired follow the range adjustment procedure below Using a s...

Page 7: ...g the retaining screw To remove the bubbler loosen locknut from the underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect Fittings section in...

Page 8: ...339 40319C 1100000002 2000000621 Hanger Bracket Basin Stainless Steel Sensor EE Compressor Serv Pack Tubing Poly Cut To Length Assy Shroud Upper Front Side Push Drier Kit Drain Replacement EZ Brkt Tub...

Page 9: ...d Suite 200 Downers Grove IL 60515 U S A 630 574 8484 www elkay com Figure 12 23 21 1 8 14 25 19 24 5 See Figure 9 Figure 11 Sensor Eye Adjustment screw 18 2 See Figure 12 19 13 10 19 17 9 19 20 15 7...