IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

Installation/Care/Use Manual

Fully-Recessed Barrier-Free Water Cooler

FIG. 1

FIG. 2

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER 

LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY 

FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, 

CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL 

CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS 

INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO 

ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.

To assure you install this model easily and correctly, PLEASE READ THESE 

SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK 

YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL 

AND OTHER APPLICABLE CODES. After installation, leave these instructions 

inside the fountain for future reference.

Installer

19

B

C

A

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED 

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE 

PULLING IT OUT HELPS TO 

RELEASE TUBE

A

B

C

USES HFC-134A REFRIGERANT

Note: Danger! Electric shock hazard. Disconnect power before servicing unit.

BASIN

Summary of Contents for LJNED10 2AQ Series

Page 1: ...LD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM To assure you install this model easily and correctly PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING...

Page 2: ...and top of chiller unit 4 102mm minimum required 3 Install rough plumbing to fountain See Figure 4 for location of supply water inlet to chiller and location of waste water outlet 4 Install wall frame...

Page 3: ...OFF VALVE BY OTHERS C 1 1 4 32mm DRAIN TUBE PROVIDED D ELECTRICAL INLET 26 1 2 673mm 11 279mm FINISHED FLOOR 55 1 4 1403mm 24 610mm 16 406mm 18 457mm 8 1 4 210mm 13 1 8 333mm WALL OPENING 26 3 8 670m...

Page 4: ...5 long 1 4 O D poly tubing item 24 provided into fitting on right side of filter head See Figure 7 See Figure 1 for operation of quick connect fittings 5 Install 1 4 x 1 4 John Guest elbow provided to...

Page 5: ...Make connection between chiller inlet and building supply line 3 8 O D copper tube DO NOT SOLDER TUBES INSERTED INTO THE UNIONS AS DAMAGE TO THE O RINGS MAY RESULT See Figure 9 Make connections betwe...

Page 6: ...PAGE 6 LJNED10_2AQ 1000002311 Rev D 05 16 TUBE ROUTING DIAGRAM TO BUBBLER REGULATOR ASSEMBLY SEE FIGURE 16 TO CUP FILLER CHILLER INLET CHILLER OUTLET 3 24 24 31 FIG 11...

Page 7: ...enser approximately 150 lbs or 68 kg 3 Orientate yourself to the configuration of the cup dispenser and remove waste bin Note location of mounting slots in the wall box portion of the cup dispenser se...

Page 8: ...replacement is necessary see parts list for correct regulator part number Actuation of Quick Connect Water Fittings Cooler is provided with lead free connectors which utilize an o ring water seal To r...

Page 9: ...8 24 CP 17 40169C NUT HEX 1 5 16 20UN CP 18 40562C GLASS FILLER 19 97466C BUBBLER ASSEMBLY VR 20 45929C TUBE DRAIN 21 50986C HOLDR REGULATOR 22 51294C ASSY FILTER HEAD 23 51299C ASSY FILTER LK LEAD 24...

Reviews: