background image

97628C (Rev. H - 8/04)

HRC30-1B

TROUBLE SHOOTING AND MAINTENANCE

Temperature Control:

  Factory set for 50°F water under normal conditions.

To adjust water temperature, turn screw on Item No. 7 clockwise for colder,

counter clockwise for warmer.

Ventilation:

  Cabinet louvers and condenser fins should be periodically

cleaned with a brush, air hose, or vacuum cleaner. Excess dirt or poor

ventilation can cause no cold water and compressor cycling on the overload

protector.

Lubrication:

  Motors are lifetime lubricated.

Actuation of Quick Connect Water Fittings: 

 Cooler is provided with lead-

free plug which utilizes an o-ring seal. To remove plug from cooler, relieve

water pressure, pull the collar towards the fitting and pull the fitting off the

tube. To install plug, push fitting straight onto tubing until it reaches a

positive stop, approximately 3/4”.

ITEM

NO.

PART  NO.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

*29

30

28165C

28218C

28166C

28167C

23158C

27702C

35882C

35792C

31180C

31181C

66620C

66621C

36045C

35984C

35989C

35988C

35990C

30040C

50196C

66624C

70772C

66623C

70020C

34783005

28408C

30039C

70274C

36034C

35985C

35895C

ITEMIZED PARTS LIST

DESCRIPTION

*INCLUDES COMPRESSOR, OVERLOAD & CSIR BOX

ASSEMBLY.  IF UNDER WARRANTY, REPLACE WITH

SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.

NOTE:  All correspondence pertaining to any of the

above water cooler or orders for repair parts MUST

include model number and serial number of cooler, name

and part number of replacement part.

Box - Insulation

Base Assy

Panel

Panel - Front

Cover - Insulation Box

Cabinet

Control - Cold

Fan Motor

Fan Blade

Fan Bracket

Condenser

Drier

Overload Cover

Overload

Gasket (Terminal Cover)

Overload Spring

Bale Strap

Electrical Box Cover

Grommet

Evaporator Assy

Drain Plug

Heat Exchanger

Nut

Washer - Lock

Panel - Rear

Electrical Box

Compressor Sleeve

CSIR Box Assy

Compr. Service Pak

Freeze Control

115V Wiring

Diagram

13, 14, 15,

16, 17

3

28

25

8

10

9

11

6

29

4

20, 23, 24

22

21

1

7

5

2

19, 27

12

18, 26

30

Reviews: