Service: Inspection/Cleaning

     •     Inspect Cooler twice each year for proper operation and performance.

     •     Inspection of the unit will require disconnecting electrical supply, removal of panels, etc.

           and reassembly and return to service practices.

1.  Cleaning: Warm, soapy water or mild household cleaning products can be used to clean the exterior panels. Extra caution should be used to clean 

the mirror finished stainless steel panels. They can be easily scratched and should only be cleaned with mild soap and water or Windex glass 

cleaner and a clean, soft cloth. Use of harsh chemicals or petroleum based or abrasive cleaners will void the warranty.

2.  Bubbler

: Mineral deposits on the orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a 

small round file not over 1/8” (3 mm) diameter or small diameter wire.

•  CAUTION

: DO NOT file or cut orifice material. Care must be taken not to damage the orifice(s)  

3.  Condenser Fan Motor

:   Confirm condenser fan turns freely. If the condenser fan does not spin freely, have an authorized service personnel 

replace.

4.  Ventilation

: Cabinet louvers and condenser fins should be periodically cleaned with a brush, air hose or vacuum cleaner. Cleaning should be done 

twice each year or more frequently if needed due to environment. Excess dirt or poor ventilation can cause no cold water and compressor cycling 

on the compressor overload protector.

5.  Water Flow

:    Confirm proper water flow. If water flow is slow, inspect filter or inline strainer for restriction. Replace filter cartridge if required.  

Disassemble inline strainer and clean if required  See Figure 6.

6.  Lubrication: Motors are lifetime lubricated.

7.  Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize o-ring water seal. To remove tubing from the 

fitting, relieve water pressure, push in on the gray collar before pulling on the tubing.  To insert tubing, push tube straight into fitting until it reaches 

a positive stop, approximately 3/4” (19mm).  See Figure 7.

Service: Inspection/Replacement

     •     Inspect Cooler twice each year for proper operation and performance.

     •     Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices.
1.  Bubbler

: To remove the bubbler, first disconnect the electrical supply.  Remove the Front Panel by removing (2) screws.  To remove the bubbler, 

loosen locknut from the underside of the basin and remove the tubing from the quick connect fitting (see Figure 7 for actuation of Quick Connect 

Fittings). When installing replacement bubbler, tighten nut only to hold parts snug in position. Do Not Overtighten.  After servicing, replace the 

front panel and two (2) screws. 

2.  Cleaning Strainer

:  Restricted water flow may be caused by clogged screen.  Remove plug and screen. Clean screen and replace. Lubricate 

O-Ring with food grade pharmaceutical mineral oil. Do not overtighten plug or fittings.  See Figure 6.

A

C

B

D

A = Plug with 7/8" (22.2mm) Hex

B = O-ring

C = Screen

D = Strainer Body with 1" (25.4mm) Hex

Figure 6

Figure 7

Figure 4

Figure 5

Figure 8

- When provided

6

5

4

3

1

7

2

8

ITEM 

NO.

Filter Head Ass’y

Screw #8-18 X .75 PH

Fitting - Superseal 3/8”(10mm)

Fitting - Superseal 1/4” (6mm)

Filter Ass’y

Elbow - 3/8” (10mm)

Elbow - 1/4” (6mm)

Bracket

1

2

3

4

5

6

7

8

51294C

70792C

70823C

70822C

51299C

70818C

70817C

22490C

DESCRIPTION

PART

NO.

WATERSENTRY

® 

 

FILTER PARTS LIST 

(See Fig. 3) 

BASIN

1

COVER NUT

BUTTON

2

BASIN

8

Locknut

Summary of Contents for FD7003*F2YJO Series

Page 1: ...ion keep these instructions in a safe location for future reference Electric supply must be identical in voltage cycle and phase to that specified on nameplate Electrical supply must have Ground Fault Circuit Interrupter GFCI protection A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules This is to allow electrical discon...

Page 2: ... Gloves o 5 16 7 9mm Hex Driver or Flathead Screwdriver o C 13 Modular International Power Cord Set Installation Cooler Mounting 1 Select installation location Installation location must be a flat surface Installation location should ensure proper ventilation by maintaining 4 102mm minimum clearance from cabinet louvers to wall 2 Remove front panel Item 26 by unscrewing 2 5 16 7 9mm Hex Head screw...

Page 3: ...Service For proper and safe servicing please read these instructions completely All Service and Maintenance must be performed by an authorized service personnel Disconnect electrical supply to the unit before any service work to reduce risk of electrocution Shut off water supply serving the unit before any service work to reduce risk of water damage DANGER CAUTION Tools Items required but not prov...

Page 4: ...r and clean if required See Figure 6 6 Lubrication Motors are lifetime lubricated 7 Actuation of Quick Connect Water Fittings Cooler is provided with lead free connectors which utilize o ring water seal To remove tubing from the fitting relieve water pressure push in on the gray collar before pulling on the tubing To insert tubing push tube straight into fitting until it reaches a positive stop ap...

Page 5: ...73C 36243C 98748C 66704C 0000000241 0000000254 66809C 98773C 35827C 0000000243 30824C 56237C 42677000 21958C 21482C 20460C 21959C 21487C 21486C 21239C 28196C 66743C 35826C 31486C 31455C 31456C 31457C 31458C 31459C 31460C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 NS NS Kit Push Button Assy Kit Regulator w Spring Gasket GF Bubbler Nipple Assy GF Strainer Tubing Poly Cut to Lengt...

Reviews: