PAGE 3
FD700_3_2JJO, FD700_5_2JJO
1000003126 (Rev. A - 12/15)
Rough-In: SCWT14A
Operation: Start-Up
1. Turn on the building water supply and check all connections for leaks.
2. Purge air from all water lines by activating pushbutton with your hand.
3.
Recheck all water and drain connections with water flowing through system.
4. Rotate fan to ensure proper clearance and free fan action.
5. Connect plug-end of International Power Cord Set (sold separately) into electrical outlet.
6. After verifying that the water cooler is properly connected and operational, replace and reattach cooler front panel (Item 26) by tightening (2)
screws.
A = Water Mains Supply, 3/8” (9.5mm) O.D. compression outlet of Shut-off Valve (not provided) to be 1-1/2” (38mm) from Wall
B = Waste Outlet, 1-1/4” (31.8mm) O.D. Drain Tube
C = 1-1/4” (31.8mm) Trap (not provided)
D = Power Inlet. Electrical Mains Supply Duplex Outled, 3-wire in Recessed Box. Must have Ground Fault Circuit Interrupter (GFCI) protection
E = Ensure proper ventilation by maintaining 4” (102mm) minimum clearance from cabinet louvers to wall
F =
To level unit, loosen screws to adjust base for contact with floor. Tighten screws after unit has been leveled.
Figure 3
Service
For proper and safe servicing, please read these instructions completely.
• All Service and Maintenance must be performed by an authorized service personnel.
• Disconnect electrical supply to the unit before any service work to reduce risk of electrocution.
• Shut off water supply serving the unit before any service work to reduce risk of water damage.
DANGER
CAUTION
• Tools/Items required but not provided, for Servicing:
o Safety Glasses
o Protective gloves
o 5/16" (7.9mm) Hex Driver or Flathead Screwdriver
Service: Adjustments
1. Temperature Control: Factory set for 50ºF ± 5º (10ºC ± 2.8º) water under normal conditions. To adjust water temperature, remove front panel
(Item 26) by unscrewing (2) 5/16" (7.9mm) Hex Head screws. Set panel aside. Turn screw on cold control (Item 15) clockwise for colder, counter
clockwise for warmer. See Figure 10.
2. Water Stream Height: Stream height is factory set at 35 psig (0.24MPa). If supply varies greatly from this, remove items 1 and 2 and adjust
screw on item 4. Clockwise adjustmentwill raise stream height and counter-clockwise adjustment will lower stream. For best adjustment,
stream should hit basin approximately 6-1/2" (165mm) from bubbler. See Figure 5 and 10.
3. Water coming out of Bubbler continuously: When this occurs at the end of the compressor cycle, turn the cold control warmer (Item 15) counter-
clockwise 1/4 of a turn. See Figure 10.
D