background image

Page 5

2000000498  (Rev. A - 01/22)

EZWSSMJO_2A

VERIFY CONTROL BOARD  SOFTWARE

1) To verify the software program of the control board the 

    unit will need to be shut down and restarted. The chiller

    (if present) does not need to be shut down and restarted.

2) The units lower panel must be open to access the power 

    cord and wall outlet.

3) Shut down the unit by unplugging the power cord from the 

    wall outlet. 

4) 

 

Restart the unit by plugging the power cord back into the 

    wall outlet.

5) Upon start up the bottle count display will show the 

    software designation of BF9 or BF11. 

6) Reference the BF9 or BF11 instructions for  

    setting the

 

control board.

ACCESSING THE PROGRAMMING BUTTON

1) 

  

To access the program button remove the top cover of 

    

the bottle filler. Remove the  two (2) screws holding top  

    

cover to bottle filler with a 5/32” allen wrench . Remove 

    top cover. Do not discard mounting screws, they will be 

    

needed to reinstall the top cover

 

after programming 

    operations are completed. The programming button is 

      

located at the top right side of the unit on the control board.

RESET THE FILTER MONITOR

1) Instructions apply to filtered units only.

2) Depress the program button for approximately 2 seconds

    until the display changes then release. The display will

    change and scroll through two messages:

       “RST FLTR” – Reset Filter Monitor

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display

    will scroll through the two messages above for

    three cycles and then default back to bottle count and

     be back in run mode.

3) When the display changes to “RST FLTR”, depress

    the button again. The display will change to show

     “FLTR =”. Depress the button again and the display

    will show “FLTR =0”

4) The Green LED should be illuminated indicating that
    the visual filter monitor has been reset. 

 SETTING RANGE OF THE IR SENSOR

1) Depress the program button for approximately 2 seconds

    until the display changes then release. The display will

    change and scroll through two messages:

       “RST FLTR” – Reset Filter Status LED

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display 

    will scroll through the two messages above for 

    three cycles and then default back to bottle count 

     and be back in run mode.

2) When the display changes to “SETTINGS”, depress

    the button again. The display will change to show

     “RNG SET” -  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

      “FLT SIZE” - Select filter capacity

     “RST BCNT” - Reset bottle count

3)  When display shows “RNG SET” push program

    button once the display will show current value

     (can be 1 – 10) e.g. “RNG = 3”.

4) Once display shows current value push the 

    program button to scroll through value of 1 – 10.

    Select the desired range setting.

5) Once range is selected allow approximately

    4 seconds to pass and then the display will go 

     back to bottle counter and be in run mode.

6)  Test bottle filler by placing bottle or hand in front
    of sensor to make sure water is dispensed.

SETTING UNIT TYPE

1) Depress the program button for approximately 2 seconds

    until the display changes then release. The display will

    

change and scroll through two messages:

      

“RST FLTR” – Reset Filter Status LED

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display 

    

will scroll through the two messages above for 

    three cycles and then default back to bottle count 

      

and be back in run mode.

2) 

 

When the display changes to “SETTINGS”, depress

    the button again. The display will change to show

     

“RNG SET” -  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

      “FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

3) 

 

When display shows “UNIT TYPE” push program 

    

button once the display will show current value

       

Can be REFRIG or NON-RFRG

4) Push button once to change value. Once value is

      

selected the display will show the new value.

       

(Can be REFRIG or NON-RFRG)  

     

“REFRIG“ - stands for refrigerated product. In this 

     setting the flow rate is estimated at 1.0 gallon per minute.

     

“NON-RFRG“ - stands for nonrefrigerated product. 

    In this setting the  flow rate is estimated 

      

at 1.5 gallons per minute.

      Both “REFRIG“ and “NON-RFRG“ simulate 

       

1 bottle equal to 20 oz.

5) 

 

Allow approximately 4 seconds to pass and the display

     

will return to bottle counter and be in run mode.

    

 RESETTING BOTTLE COUNT

1) Depress the program button for approximately 2 seconds

    until the display changes then release. The display will

    

change and scroll through two messages:

      

“RST FLTR” – Reset Filter Status LED

      

“SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display 

    

will scroll through the two messages above for 

    three cycles and then default back to bottle count 

     

and be back in run mode.

2)  When the display changes to “SETTINGS”, depress

    the button again. The display will change to show

     

“RNG SET”-  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

      

“FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

    If the button is not pushed again the display will scroll

    through the four messages above for three cycles and

     

return to run mode.

3) 

 

When display shows “RST BCNT” push program button

    

once the display will show current value e.g. “00033183”.

4) Once display shows current value push the program

    button once more to reset back to 0. The display will

    show BTLCT = 0 for approximately 2 seconds and 

    then return to run mode showing 00000000 bottles.

5) 

 

Testing the bottle counter:

     REFRIG units: Place bottle or hand in front of sensor

       for 9.4 seconds to see bottle counter count 00000001.

     

    (This is based on filling a 20 oz. bottle)

     NON-RFRG units: Place bottle or hand in front of sensor

       for 6.25 seconds to see bottle counter count 00000001.

         (This is based on filling a 20 oz bottle)

BF11 PROGRAM

SETTING THE CONTROL BOARD

Reviews: