background image

Page 4

98550C  (Rev. B - 8/10)

LZS8WS*1A,  LZSDWS*1A,  LZSTL8WS*1A,  LZSTLDWS*1A

 LZS8WS*2A,  LZS8WS*3A,  LZSTL8WS*2A,  LZSTL8WS*3A

CHANGING THE FILTER AND RESETTING THE VISUAL FILTER MONITOR

The electronic sensor includes LED filter status indicators that are factory preset to monitor filter life. The sensor monitors the “ON” time
of the water valve solenoid and keeps track of total time water is dispensed.
There are (3) LED’s that indicate the following:

Green:

 LED (Good) indicates that the filter is operating within 0% - 80% of its life.

Yellow:

 LED indicates that the filter is operating within 80% - 100% of its life.

Red:

 LED (Replace) indicates that the filter needs to be replaced since it has reached end of filter life.

TO CHANGE THE FILTER:

1)

Remove the lower front panel of the watercooler by removing the four (4) screws

2)

Turn inlet water valve off.

3)

Open bubbler to relieve pressure build-up in the system.

4)

Remove filter from head by rotating filter counterclockwise.

5)

Remove new filter from carton, remove protective cap; cap may be placed on old filter to reduce the chance of water spilling from
filter housing.

6)

Attach filter to filter head by firmly inserting into head and rotating filter clockwise.

7)

Turn on water supply and hold open the bubbler on cooler until approximately 1 gallon of water is dispensed. This flushing
procedure purges air and fine carbon particles from the filter.

TO RESET THE FILTER MONITOR:

1)

In order to reset the visual filter monitor status LED’s, you must remove the top cover of the bottle filler. Remove the  two (2) screws
with  a 5/32 allen wrench holding top cover to Bottle Filler. Remove top cover. Do not discard mounting screws, they will be needed
to reinstall the top cover

2)

With your finger, reach inside the opening and depress the program button located behind  the LCD display outside of the electron-
ics cover for approximately 2 seconds until the display changes then release.  The display will change and scroll through three
messages:

“RST FLTR”

 – Reset Filter Status LED

“RST BCNT”

 – Reset Bottle Count

“RNG SET”

 – Range Set for IR Sensor

If the program button is not pushed again the display will scroll through the three messages above for three cycles and then default
back to bottle count and be back in run mode.

3)

When the display  changes  to “RST FLTR”, depress the button again. The display will change to show “FLT =”. Depress the button
again and the display will show  “FLTR =0”

4)

The Green LED should be illuminated indicating that the visual filter monitor has been reset. Reinstall the top cover.

SETTING THE CONTROL BOARD – SETTING RANGE OF THE IR SENSOR

1)

In order to access the programming button, you must remove the top cover of the bottle filler. Remove the  two (2) screws with a

       5/32” allen wrench holding top cover to Bottle Filler. Remove top cover. Do not discard mounting screws, they will be needed to

reinstall the top cover

2)

With your finger, reach inside the opening and depress the program button located behind  the LCD display outside of the

      electronics cover for approximately 2 seconds until the display changes then release.  The display will change and scroll through

three messages:

“RST FLTR”

 – Reset Filter Status LED

“RST BCNT”

 – Reset Bottle Count

“RNG SET”

 – Range Set for IR Sensor

If the program button is not pushed again the display will scroll through the three messages above for three cycles and then default
back to bottle count and be back in run mode.

1)

To set the RANGE of IR Sensor:  when display shows “RNG SET” push program button once the display will show current value (can
be 1 – 10) i.e. 

“RNG = 3”

.

2)

Once display shows current value push the program button to scroll through value of 1 – 10.  Select the desired range setting.

3)

Once range is selected allow approximately 4 seconds to pass and then the display will go back to bottle counter and be in run
mode.

4)

Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed.

 

SETTING THE CONTROL BOARD – RESETTING BOTTLE COUNT

1)

In order to access the programming button, you must remove the top cover of the bottle filler. Remove the  two (2) screws with  a 5/
32 allen wrench holding top cover to Bottle Filler. Remove top cover. Do not discard mounting screws, they will be needed to
reinstall the top cover

2)

With your finger, reach inside the opening and depress the program button located behind  the LCD display outside of the electron-
ics cover for approximately 2  seconds until the display changes then release.  The display will change and scroll through three
messages:

“RST FLTR” 

– Reset Filter Status LED

“RST BCNT”

 – Reset Bottle Count

“RNG SET”

 – Range Set for IR Sensor

If the program button is not pushed again the display will scroll through the three messages above for three cycles and then default
back run mode which display bottle count.

3)

To reset the BOTTLE COUNTER:  when display shows “RST BCNT” push program button once the display will show current value
i.e. “BC0033183”.

4)

Once display shows current value push the program button once more to reset back to 0.  The display will show BTLCT = 0 for
approximately 2 seconds and then return to run mode showing 00000000 bottles.

5)

To test bottle counter, you can place bottle or hand in front of sensor for approx 5 seconds to see bottle counter count 00000001.
(This is based on filling a 16 oz bottle)

Summary of Contents for EZH2O LZS8WS 1A Series

Page 1: ...LER PLEASE NOTE THE GROUNDING OF ELECTRICAL EQUIPMENT SUCHAS TELEPHONE COMPUTERS ETC TO WATER LINES IS ACOMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICALFEEDBACK INTOAFOUNTAIN CREATINGAN ELEC TROLYSIS WHICH CAUSESAMETALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION ISAVOIDABLE BY USING THE PROPER ...

Page 2: ...WS 2A LZS8WS 3A LZSTL8WS 2A LZSTL8WS 3A 17 7 8 454mm 15 381mm 7 178mm 7 178mm O 7 16 11mm MOUNTING HOLES 6 3 9 16 90mm 18 13 16 478mm 3 9 16 90mm 17 7 8 454mm 18 13 16 478mm 15 381mm 7 178mm 7 178mm O 7 16 11mm MOUNTING HOLES 6 Single Rough In Fig 1 Two Level Rough In Fig 2 ...

Page 3: ...place a towel or soft cloth overthe entire basin when working above it 10 With the power cord wire s and waterline through hole on top of water cooler place Bottle Filler on the three 3 angled tabs protuding from the wall mounting plate installed on wall See Fig 9 Make sure rubber Drain Mat is installed properly on bottom of Bottle filler See Cover Illustration 11 Once Bottle Filler is installed o...

Page 4: ...CONTROL BOARD SETTING RANGE OF THE IR SENSOR 1 In order to access the programming button you must remove the top cover of the bottle filler Remove the two 2 screws with a 5 32 allen wrench holding top cover to Bottle Filler Remove top cover Do not discard mounting screws they will be needed to reinstall the top cover 2 With your finger reach inside the opening and depress the program button locate...

Page 5: ... Codo 3 8 10 mm Fijador Ens de tête de filtre Vis 8 18 x 75 hp Raccord Superseal 3 8 10mm Raccord Superseal 1 4 6mm Ens filtre Coude 3 8 10mm Support WATERSENTRY PLUS FILTER PARTS LIST See Fig 7 LISTA DE PIEZAS DEL FILTRO Vea Fig 7 LISTEDESPIÈCESDUFILTRE Voir Fig 7 DRAIN MAT EXPLODED VIEW Fig 8 Short Screws Long Screws Drain Cover Drain Mat Nuts DESCRIPTION 98543C 98544C 98545C 98546C 98547C 98548...