background image

Page 3

98550C  (Rev. B - 8/10)

LZS8WS*1A,  LZSDWS*1A,  LZSTL8WS*1A,  LZSTLDWS*1A

LZS8WS*2A,  LZS8WS*3A,  LZSTL8WS*2A,  LZSTL8WS*3A

Fig. 5

 Note:  Screw the locknut hand tight to seal

Fig. 6

BOTTLE  FILLER  INSTALLATION

1)   Remove two (2) mounting screws with 5/32” allen wrench holding top cover to  Bottle Filler (See FIG. 4). Remove top cover. Note do not discard mounting
      screws, they will be needed to reinstall top cover..
2)   Remove wall mounting plate from Bottle Filler. Place Wall plate against wall on top of EZ basin.  Center the wall plate side to side with the EZ basin. Mark
     the six (6) mounting holes with a pencil (See FIG. 3).
3)   Remove wall mounting plate from wall. 

NOTE:

 Mounting plate 

MUST

 be supported securely. Add fixture support carrier if wall will not provide adequate

     support.
4)   Install wall mounting plate to wall using six (6) 7/16” obround mounting holes (mounting bolts not included) (See FIG. 3). Use appropriate fasteners for
      your wall type.
5)    

 Locate plastic bushing (provided) and place in basin hole by pushing into hole until it snaps into place. This bushing protects the water line, wire(s),

       and power cord from sharp edge of basin.  

This part must be used.

6)   Place Drain Mat into position on the bottom of the Bottle Filler Unit.
7) 

   Fish the purple wire (single units) or the purple and yellow wires (two-level units) up through basin hole.

8)   

For Single Model installations:

 Attach the purple wire from cooler to the purple wire on the back of the unit, (Note yellow wire is not used).

8a) 

 For Two-Level model installations:

 Attach the purple and yellow wires from coolers to the purple and yellow wires on the back of the unit, purple to

      purple, yellow to yellow.
9)   Remove 3/8” to 1/4” reducing union from end of waterline, (do not throw away it will be needed later). Lay Bottle Filler on water cooler basin and cut
      insulation from tube even with bottom of unit, remove this insulation from the 3/8” tube, but do not discard.  Fish the power cord (not supplied on 220V
      models), and waterline through the hole on top of water cooler created from the “Water Cooler Preparation” section. NOTE: To prevent scratching the basin
     place a towel or soft cloth overthe entire basin when working above it.
10)  With the power cord, wire(s), and waterline through hole on top of water cooler place Bottle Filler on the three (3) angled tabs protuding from the wall
       mounting plate, installed on wall (See Fig. 9).  Make sure rubber Drain Mat is installed properly on bottom of Bottle filler (See Cover Illustration).
11)  Once Bottle Filler is installed on wall plate tabs, drain mat, water line, wire(s) and power cord are installed properly, push top of Bottle Filler toward
      wall and line up top cover two (2) holes.
12)  Reinstall Top Cover on Bottle Filler (See FIG. 4)  with two mounting screws from step 1 above. Caution do not over tighten screws.
13)  Install remaining tube insulation to the water line from bottle filler, connect Bottle Filler waterline inside of the water cooler by
      connecting the 3/8” water line with the 3/8” to 1/4” union and short piece of poly tube that was previously installed to the tee.
14)  Install filter cartridge, remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter
      clockwise.

 NOTE: If existing plumbing roughin locations (Drain, Water In, Electric Supply) do not allow the filter to be mounted inside the cooler cabinet

      the filter can be installed horizontally below the unit.  A retrofit kit is available to mount the filter beneath the cooler.

15)  Turn water supply on and inspect for leaks. Fix all leaks before continuing.
16)  Once unit has been inspected for leaks and any leaks found corrected plug Bottle Filler and EZ unit into wall. Be sure to reinstall fuse to the circuit or
      switch the circuit breaker back to the “ON” position.
17)  Once power is applied to Bottle Filler, the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter.
18)  Verify proper dispensing by placing cup, hand, or any opaque object infront of sensor area and verify water dispenses.  Note: the first intitial dispenses
       might have air in line which may cause a sputter.  This will be eliminated once all air is purged from the line.
19)  Once unit tests out, install Lower Panel back on EZ water cooler(s).  Units are now ready for use.

7/16” BOLT  HOLES FOR
FASTENING UNIT TO WALL

UNIT CENTER LINE

TOP COVER

MOUNTING

SCREWS

Fig. 3

Fig. 4

Summary of Contents for EZH2O LZS8WS 1A Series

Page 1: ...LER PLEASE NOTE THE GROUNDING OF ELECTRICAL EQUIPMENT SUCHAS TELEPHONE COMPUTERS ETC TO WATER LINES IS ACOMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICALFEEDBACK INTOAFOUNTAIN CREATINGAN ELEC TROLYSIS WHICH CAUSESAMETALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION ISAVOIDABLE BY USING THE PROPER ...

Page 2: ...WS 2A LZS8WS 3A LZSTL8WS 2A LZSTL8WS 3A 17 7 8 454mm 15 381mm 7 178mm 7 178mm O 7 16 11mm MOUNTING HOLES 6 3 9 16 90mm 18 13 16 478mm 3 9 16 90mm 17 7 8 454mm 18 13 16 478mm 15 381mm 7 178mm 7 178mm O 7 16 11mm MOUNTING HOLES 6 Single Rough In Fig 1 Two Level Rough In Fig 2 ...

Page 3: ...place a towel or soft cloth overthe entire basin when working above it 10 With the power cord wire s and waterline through hole on top of water cooler place Bottle Filler on the three 3 angled tabs protuding from the wall mounting plate installed on wall See Fig 9 Make sure rubber Drain Mat is installed properly on bottom of Bottle filler See Cover Illustration 11 Once Bottle Filler is installed o...

Page 4: ...CONTROL BOARD SETTING RANGE OF THE IR SENSOR 1 In order to access the programming button you must remove the top cover of the bottle filler Remove the two 2 screws with a 5 32 allen wrench holding top cover to Bottle Filler Remove top cover Do not discard mounting screws they will be needed to reinstall the top cover 2 With your finger reach inside the opening and depress the program button locate...

Page 5: ... Codo 3 8 10 mm Fijador Ens de tête de filtre Vis 8 18 x 75 hp Raccord Superseal 3 8 10mm Raccord Superseal 1 4 6mm Ens filtre Coude 3 8 10mm Support WATERSENTRY PLUS FILTER PARTS LIST See Fig 7 LISTA DE PIEZAS DEL FILTRO Vea Fig 7 LISTEDESPIÈCESDUFILTRE Voir Fig 7 DRAIN MAT EXPLODED VIEW Fig 8 Short Screws Long Screws Drain Cover Drain Mat Nuts DESCRIPTION 98543C 98544C 98545C 98546C 98547C 98548...