background image

98140C (Rev. - 3/05)

DRKR14C

Page 2

1. Make 13-1/4” (337mm) diameter cutout in desired location
   on countertop. Maintain the 7-5/8” (194mm) dimension
     from the front edge for ADA compliance. (See Figure 1)
2.  Install bubbler assembly to fountain. Align recess in
      underside of bubbler with dimple in fountain.
3.  Apply caulk (not provided) around cutout and waste
     opening.
4.  Place fountain over opening and drop in strainer.
     (See Figure 2)
5.  From underside, position and secure tiedown bracket
     using waste fitting. (See Figure 3)
6.  Use screws with nuts and washers (provided) to tighten
      unit to countertop. Wipe off excess caulking.
      (See Figure 3)
7.  Determine required length of waste line and cut to
     appropriate length. 1-1/4” O.D. waste tube furnished.
     1-1/4” slip trap, waste elbow and extension not
      provided.
8.  Make water supply connections from service stop to the
     3/8” O.D. unplated brass nipple coming out of the
     bubbler. Turn on water supply and check for leaks. Newly
     installed water supply line should be insulated after leak
     check is completed.

9.  These products are designed to operate on 20-105
     PSIG supply line pressure. If the supply pressure is
     above 105 PSIG, a pressure regulator must be installed
      in the supply line. Any damage caused by reason of
     connecting these products to supply line pressures
      lower than 20 PSIG or higher than 105 PSIG is not
       covered by warranty.

BUBBLER DETAIL

NOTE:

When installing replacement bubbler and pedestal, tighten
nut (Item 4) only to hold parts snug in position.  Do Not
Overtighten.

Basin

Figure 4 - Bubbler Details

1

2

5

6

7

Figure 1

Figure 2

Figure 3

8

9

3

10

4

11

Reviews: