98140C (Rev. - 3/05)
DRKR14C
Page 2
1. Make 13-1/4” (337mm) diameter cutout in desired location
on countertop. Maintain the 7-5/8” (194mm) dimension
from the front edge for ADA compliance. (See Figure 1)
2. Install bubbler assembly to fountain. Align recess in
underside of bubbler with dimple in fountain.
3. Apply caulk (not provided) around cutout and waste
opening.
4. Place fountain over opening and drop in strainer.
(See Figure 2)
5. From underside, position and secure tiedown bracket
using waste fitting. (See Figure 3)
6. Use screws with nuts and washers (provided) to tighten
unit to countertop. Wipe off excess caulking.
(See Figure 3)
7. Determine required length of waste line and cut to
appropriate length. 1-1/4” O.D. waste tube furnished.
1-1/4” slip trap, waste elbow and extension not
provided.
8. Make water supply connections from service stop to the
3/8” O.D. unplated brass nipple coming out of the
bubbler. Turn on water supply and check for leaks. Newly
installed water supply line should be insulated after leak
check is completed.
9. These products are designed to operate on 20-105
PSIG supply line pressure. If the supply pressure is
above 105 PSIG, a pressure regulator must be installed
in the supply line. Any damage caused by reason of
connecting these products to supply line pressures
lower than 20 PSIG or higher than 105 PSIG is not
covered by warranty.
BUBBLER DETAIL
NOTE:
When installing replacement bubbler and pedestal, tighten
nut (Item 4) only to hold parts snug in position. Do Not
Overtighten.
Basin
Figure 4 - Bubbler Details
1
2
5
6
7
Figure 1
Figure 2
Figure 3
8
9
3
10
4
11