M1XRFTW Installation Manual

Switch Settings

S1

S2

S3

S4

Off

On

Off

Off

On On

Off

Off

Off Off

On

Off

On

Off

On

Off

Off

On On

Off

On On On

Off

Off Off Off

On

On

Off Off

On

Off

On

Off

On

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Data Bus

Address

2
3
4
5
6
7
8
9

10
11
12
13
14
15

Other Jumper

Settings:

JP1 - Used to
engage a 120

Ohm resistor for

terminating the

RS-485 Data Bus.

See Data bus

wiring instructions

before use.

Suggested Wireless

"Starting Point"

Zone 17
Zone 33
Zone 49
Zone 65
Zone 81
Zone 97

Zone 113
Zone 129
Zone 145

not valid
not valid
not valid
not valid
not valid

Switch Settings

S1

S2

S3

S4

Off

On

Off

Off

On On

Off

Off

Off Off

On

Off

On

Off

On

Off

Off

On On

Off

On On On

Off

Off Off Off

On

On

Off Off

On

Off

On

Off

On

On On

Off

On

Off Off

On On

On

Off

On On

-

-

-

-

-

-

-

-

Data Bus

Address

2
3
4
5
6
7
8
9

10
11
12
13
14
15

Starting and Ending

Zone Numbers

Zones 17 - 32
Zones 33 - 48
Zones 49 - 64
Zones 65 - 80
Zones 81 - 96

Zones 97 - 112

Zones 113 - 128
Zones 129 - 144
Zones 145 - 160
Zones 161 - 176
Zones 177 - 192
Zones 193 - 208

not valid
not valid

Table 1-1

Table 1-2

M1XRF Wireless Receivers

M1XIN Zone Expanders

Data Bus Enrollment:

:

Once the address is set and the M1XRF is powered up it will be necessary to manually ENROLL the device so that the M1
Control knows it is present.  This is accomplished either from keypad programming "Menu 1 - Bus Module Enrollment" or
from the ElkRP Remote Programming Software.
(The steps below require an M1 LCD Keypad)
1.

Press the ELK key, then press 9 (or scroll up) to display 9 - Installation Programming.  Press the
RIGHT arrow key to select this menu.  The Installer Program Code (PIN) must be entered to access
this menu.

2.

Enter the Installer Program Code.  (The default code is 172839)

3.

The first Installer Programming menu displayed will be "Bus Module Enrollment"

4.

Press the RIGHT arrow key to select this menu.  "Enrolling Bus Modules" will display

5.

The control will transmit an enrollment message to all data bus devices, followed by a display
showing the total Bus Modules that are enrolled.  To view the enrolled devices and/or remove a
device press the RIGHT arrow key next to the word Edit.

6.

Press the * or Exit keys to exit Installer Programming.

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

XX Bus Modules
Enrolled, Edit 

rrrrr

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

Auth. Required
Enter Valid Pin

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

12345678901234567890123456

01-Bus Module
Enrollment

Data Bus Address Switches

Summary of Contents for M1XRFTW

Page 1: ...Box 100 3266 US Hwy 70 West Hildebran NC 28637 828 397 4200 828 397 4415 Fax http www elkproducts com IMPORTANT NOTE ELK M1G and M1EZ8 Controls require application firmware ver 5 2 8 or higher to be...

Page 2: ...NS Operating Frequency 902 Mhz to 928 Mhz Transmission Duration active on time 50 ms Sensitivity 105 dbm Operating Temperature 0 to 120 degrees F Operating Voltage 12 Volts D C Current Draw 25mA Recei...

Page 3: ...control providing greater coverage as well as redundancy Utilizing multiple receivers it is possible to cover hundreds if not thousands of square feet with a receiver placed in strategic locations A s...

Page 4: ...provide valuable information as to the operation of the M1XRF STATUS Data Bus Status Multiple conditions exist for this LED OFF No Power to the M1XRF ON Solid Power is good but it is not yet enrolled...

Page 5: ...nge and coverage redundancy multiple like branded M1XRF Wireless Receivers can be installed on the bus Redundant receivers can be assigned to any unused data bus address as long as it doesn t conflict...

Page 6: ...e ELK key then press 9 or scroll up to display 9 Installation Programming Press the RIGHT arrow key to select this menu The Installer Program Code PIN must be entered to access this menu 2 Enter the I...

Page 7: ...ower using only enough power to get a signal through thereby maximizing the battery life of the sensor Confidence of signal strength at the time of installation another unique feature of the Elk Two W...

Page 8: ...hod mentioned beside each device ElkRP Remote Programming involves typing in the TXID serial number of the sensor along with selecting the particular attributes Single Button Panic Xmtr Ademco Part 58...

Page 9: ...and HOLD on the button If the M1 Lrn Enroll function has ended or been aborted it may be necessary to restart from the beginning with Step 1 M1 Rapid Enroll Feature The M1 Rapid Enroll feature advance...

Page 10: ...456789012345678901234567890121234 123456789012345678901234567890121234 123456789012345678901234567890121234 123456789012345678901234567890121234 2 Xmit Sel b Prgr Transmitter Opt r 1234567890123456789...

Page 11: ...123456789012123 12345678901234567890123456789012123 12345678901234567890123456789012123 12345678901234567890123456789012123 12345678901234567890123456789012123 12345678901234567890123456789012123 1234...

Page 12: ...2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Starting Zn ID 49 Data Bus Addr 4 Zn 49 64 M1XRF Cells marked indicate a Reserved Address which can only be used for wireless zones Cells marked RRF indicate bus ad...

Page 13: ...r 11 Zn 161 176 M1XRF Data Bus Addr 2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Data Bus Addr 4 Zn 49 64 Data Bus Addr 5 Zn 65 80 Data Bus Addr 6 Zn 81 96 Data Bus Addr 7 Zn 97 112 Data Bus Addr 8 Zn 113 128...

Page 14: ...13 128 Zones 129 144 Zones 145 160 Zones 161 176 Zones 177 192 Zones 193 208 Bus Addr x Bus Addr 2 Bus Addr 3 Bus Addr 4 Bus Addr 5 Bus Addr 6 Bus Addr 7 Bus Addr 8 Bus Addr 9 Bus Addr 10 M1XIN or Key...

Page 15: ...Updates directory This is where RP looks for all update files 7 Click on the check box for Update If Reprogram or Rollback is displayed the firmware file is the same as OR older that what is in the c...

Page 16: ...Page 16 M1XRFTW Installation Manual...

Reviews: