background image

 

 

 

1.  First spray or flush the collector cell with 

warm water (figure 6). 

 
2. Mix the detergent solution in a suitable 

container which is large enough to hold the 
cells entirely. The proportions of the solution is 
5 to 8 parts of water to one part of ELIXAIR 
cell detergent. You can use the same solution 
2 to 5 times. 

 
3. Immerse the cells (and the prefilters if 

needed) in the detergent solution and allow to 
soak from 15 minutes to two hours. It is 
recommended to shake the cells a few times 
while soaking (figure 9). 

Summary of Contents for E 2100

Page 1: ...ion of the electronic collector cell where they receive a powerful electrical charge 8 kV 4 The charged particles travel in the air stream to the collection section of the cell and are drawn to the co...

Page 2: ...ed or where staying without any breathing protection is limited Warning Due to its mode of operation the electronic collector cell may occasionally emit sparks Never use the air purifier in a place wh...

Page 3: ...he purifier It is even possible that the clean air from the exit would flow directly back to the intake of the purifier and leave the rest of the air in the room uncleaned For best cleaning results in...

Page 4: ...move the two transport supports which hold the collector cells figure 2 6 Remove the plastic wrapping from the active carbon filters and install the filters in the grooves above the cells Close the do...

Page 5: ...in the following sequence figure 5 Y C stop C speed I C speed II C speed III C stopY 3 Repeat the same test using the remote controller Point the infra red beam from the narrow end of the remote contr...

Page 6: ...ying cigarette smoke efficiently In any large space where the content of dust and other impurities in the air is unusually high or where continuous use of the purifier on the highest fan speed is requ...

Page 7: ...urfaces using either a vacuum cleaner or any ordinary mild detergent and a damp cloth Remove the grid and the filters first to facilitate cleaning Soak the grid in a mild detergent solution not cell d...

Page 8: ...ght You can turn the cells over a few times to speed up drying 6 Check the ionization wires of the cell If the wires are dirty clean them carefully using a thin strip of plastic with a slit cut to it...

Page 9: ...the cells entirely The proportions of the solution is 5 to 8 parts of water to one part of ELIXAIR cell detergent You can use the same solution 2 to 5 times 3 Immerse the cells and the prefilters if n...

Page 10: ...nd then closing the door so that the spring loaded latches lock it tightly If the door is not properly closed the unit will not function because the safety switch controlling the door is not closed co...

Page 11: ...with the applicable harmonized standards It complies with the essential elements of low voltage directive 73 23 ETY 93 68 ETY and the directive for compatibility on electricity EMC 89 336 ETY 93 68 ET...

Page 12: ...SERVICE MEMO ELIXAIR E 2100 IR2 No Date of installation Act Act Act filter repl filte r filte r...