background image

PARAMETER

HC1

db1
dF1

HS1
LS1

dn1

do1

di1

dE1

On1

OF1

LOC

PA1

ndt
CA1

LdL
HdL

H00 (1) (!)
H03

H04
H10

rEL
tAb

UL

dL

Fr

(1) the default value is PTC (PTC input, see the label on the instrument).

* DEFAULT column: for parameters HC1/2, HS1/2, LS1/2, DF1/2, H00/03/04/10 the default depends don the model.
** VALUE column: to be filled manually, with customized settings (if different from the default value).

(!) WARNING!

• If one or more of these parameters highlighted with (!)  are modified, teh controller must be switched off and switched on again to ensure correct operation.
• It is strongly recommended, anyway to switch off and switch on again the controller anytime parameters have been changed to prevent malfunctioning on configuration
and/or ongoing timings

3/4

DESCRIPTION

REGULATOR 1 (folder with “rE1” label)

Heat/Cool Mode. If set to H the generic regulator actuates for hot
operation. If set to C the generic regulator actuates for cold opera-
tion
Intervention 1 band 

see ON-OFF regulation diagram

diFferential. Relgulator 1 (OUT1) tripping differential. The regulator
stops on reaching the Setpoint value (as indicated by the adjust-
ment probe), and restarts at temperature value equal to the
Setpoint 1 plus (or minus depending on HC1) the value of the dif-
ferential.  

see ON-OFF regulation diagram

Higher SEt. Maximum possible setpoint 1 value.
Lower SEt. Minimum possible setpoint 1 value. 

REGULATOR 1 PROTECTIVE DEVICE (folder with “rE1” label)

Delay time in activating the regulator relay after switch-on of
instrument. 
Delay after switch off. The indicated time must elapse between
switch-off of the regulator relay and the successive switch-on. 
Delay between switch-ons. The indicated time must elapse
between two successive switch-ons of the regulator.
Delay before switch-off. The indicated time must elapse between
switch-off request and the switch-off of  the regulator.
On time (regulator 1). 
Regulator activation time in the event of faulty probe. If set to “1”
with OF1 at “0” the regulator  is always on, while at OF1 >0 it
functions always in duty cycle mode.
OFF time (regulator 1). Regulator in disabled state time in the
event of a faulty probe. If set to “1” with On1 at “0” the regulator
is always off, while at On1 >0 it functions always in duty cycle
mode.

DISPLAY (folder with “diS” label)

(keyboard) LOCk (set and keys). Keyboard locking. However, you
can enter parameter programming
modify them along with the status of this parameter in order to
allow keyboard locking. y = yes; n = no
PAssword 1. When enabled (value other than 0) it constitutes the
access key for level 1 parameters.
number display type. View with decimal point. y = yes; n = no
CAlibration 1.Calibration 1. Positive or negative temperature value
added to the value read by probe 1, 
Low display Label. Minimum value the instrument is able to display.
High display Label. Maximum value the instrument is able to dis-
play.

CONFIGURATION (folder with “CnF” label)

Probe type selection, PTC or NTC. 
Lower Limit Range Current Input

Upper Limit Range Current Input
delay time in activating the outputs after switch-on WARNING! If
set = 0 it is not active; if set 

0 output will not be activated before

this time 
reLease firmware. Device version: read only parameter.
tAble of parameters. Reserved: read only parameter.

COPY CARD (folder with “Fpr”label)

Up load. Programming parameter transfer from instrument to
Copy Card.
Down load. Programming parameter transfer from Copy Card to
instrument
Format. Erasing all data in the copy card.

PLEASE NOTE using “Fr” parameter (copy card formatting)
the data within the copy card will be lost permenently. The
operation cannot be cancelled. After using the copy Card
device the controller must be switch off and switch on again

Tab. 1

Parameter Table

DEFAULT

H/C*

1

1*

0 (n.z. models)*

*
*

1

0

0

0

0

1

n

0

n
0

0*

100/100.0/1000*

420/020/010/05/01*

20*

100*

0

/
/

/

/

/

RANGE

H/C

0...30.0

0.0...30.0

LS1..HdL
LdL..HS1

0...250

0...250

0...250

0...250

0...250

0...250

n/y

0...250

n/y/int

-30.0...30.0

-99.9…HdL

LdL…100

420/020/010/05/01

-99…100 (ndt= n)

-99.0…100.0 (ndt= y)

-999…1000 (ndt= int)

as above

0...250

/
/

/

/

/

VALUE*

U.M.

flag

digit
digit

digit
digit

sec

min

min

sec

min

min

flag

num

num
num

num
num

num

num

num

min

/
/

/

/

/

IC 912/P/R/V-I

Reviews: