Note   ① only applicable when sensor is functional 

Note ② Caution required when changing from Celsius Fahrenheit as all 
parameters will change accordingly.    

 

ALARM CODES 

 

 

SPECIFICATION 

Front panel  34.5 (H) x 76mm (W) +/- 2mm 

Cut out 30 (H) x 72mm (W) +/- 1mm 

Operating temperature -5 to 55°C  

Storage temperature -10 to 65°C 

Power supply 12/24 Volt DC 

Power consumption < 10 watts 

Temperature range -40 to 90°C  

Inputs = 2 NTC sensors 1.5m  

Outputs: 

 

Compressor output 17/7Amp 

 

Fan output 10 Amp 

 

Defrost output 10 Amp  

 

Alarm output = built in buzzer 

 

Problem solver 

 

Remove power from controller 

 

E1 or E2 check probe connections, clean plug in terminals

 

 

Probes can be extended to 100m but should have good 
watertight connections, recalibration may be required for long 
extension

 

 

LA alarm = excessive temperature, allow controller to cool 
down and relocate or ventilate to keep cool

 

 

Relay failure = check full load amperage of output to ensure 
that it is below ratings on controller

 

 

Defrost will not start = check coil temperature

 

 

Fan will not start = check coil temperature

 

 

Wiring  

 

 

 

 

 

 

Warranty procedure 

1 year replacement warranty 

Return controller to supplier complete with 
probes 

Give detailed description of fault and 
equipment  