ELITE SI9180/9220DV | AUTO-VOLT
6
3.1 Environmental conditions
a) Range of the temperature of the ambient air:
During operation:
-
10
℃
~+
40
℃
After transport and storage at:
-
20
℃
~+
55
℃
b) Relative humidity of the air:
Up to 50% at 40
℃
Up to 90% at 20
℃
c) Ambient air, free from abnormal amounts of dust, acids, corrosive gases or
substances, etc. other than those generated by the welding process. And have
good air circulation.
d) Base of the welding power source inclined up to 10°
Warning!
The placement of welding machine on bevel more than 10°may result in toppling over!
3.2 Connection to supply mains
A 2 meters long supply cord is permanently connected to the welding machine. The
free end of their supply cord should be connected to a distributor box. The current
rating of the circuit breaker in supply circuit should be as follows:
Model
Current rating of circuit breaker
(A) Min / recommended
ELITE ARC 180
16/25
ELITE ARC 220
20/30
Warning!
Connection should only be done by skilled and authorized person.
Make sure the power switch of the welding machine is on the OFF position
before doing the connection.
3.3 Connection of welding cable
1. Hold the cable coupler. Aim the locking pin of cable coupler at the gap of
equipment coupler.
2. Insert the cable coupler into the equipment coupler.
3. Clockwise turn the cable coupler for about 90
to 120
until you can’t turn it
anymore to lock them.