TROUBLESHOOTING 

 

 

PROBLEMS 

POSSIBLE CAUSES 

SOLUTIONS 

The device won’t start. 
 

 

No power 

 

No need for heat 

 

Compressor protection delay 
activated (Power light is 
flashing) 

 

Make sure circuit breaker is on 

 

Check desired temperature and 
adjust if necessary 

 

When the device stops, the 
regulator imposes a 3-minute delay 
before restarting compressor to 
allow for pressure balancing. 

The displayed water temperature 
rises quickly after the compressor 
starts. 
 

 

Water intake and outlet have 
been reversed 

 

Check to see if water is circulating 
in the right direction in the pool 
water heater. 

The device works but the water does 
not reach the desired temperature. 
 

 

Water connections are reversed 

 

Heat loss is greater than the 
devices heating capacity 

 

Pool is too large for the heat 
pump model 

 

Check to see if water is circulating 
in the right direction toward 
condenser.  

 

Choose a more powerful model or 
use more than one heat pump. 

 

Choose a more powerful model or 
use more than one heat pump. 

There is a lot of water under the 
device. 
 

 

Normal runoff due to 
condensation 

 

Abnormal water leak. 

 

No action required (install a drain 
if necessary) 

 

To determine whether this is a leak, 
turn off the device until all 
condensation runoff has gone. See 
if there is still water after 24 to 48 
hours. 

There is frost on the evaporator. 
 

 

Outdoor temperature is cold 

 

Compressor works but fan does 
not work 

 

The defrost sensor is defective – 
alarm 

 

Cooling fluid level is too low 

 

Check to see if defrost is working 
(the compressor does not operate 
during defrost – only the fan 
operates) 

 

Request service online at 
www.poolheatpump.ca/serviceCall.
php 

Regulator display is hard to read. 
 

 

The regulator display is exposed 
to direct sunlight 

 

Create some shade above the 
display to make easier to read. 

The fan works, but the compressor 
does not. 
 

 

Defrost in operation (Defrost 
indicator lights up) 

 

No action required 

The fan works, but the compressor 
does not work for more than 3 hours. 
 

 

Compressor is broken, in 
thermal protection mode or 
connections are loose (Power 
light is on) 

 

Request service online at 
www.poolheatpump.ca/serviceCall.
php 

 

Summary of Contents for 100

Page 1: ... 55 65 85 100 115 130 IMPORTANT It is important to register your product with us on our web site This will help us find your warranty when you place a service call If we cannot find your warranty registration a proof of purchase will be necessary www ttifab com warranty php ...

Page 2: ...or removing any Elite equipment make sure that all breakers covering the pool area have been turned off A clearly identified breaker must be installed in order to be able to interrupt power to the heat pump in case of an emergency Never open the electrical box without having shut off all power sources to the heat pump beforehand If your heat pump is equipped with a water pump control option don t ...

Page 3: ...ned on the rating plate Elite heat pumps have a 240V 1 phase voltage Make sure you have the appropriate electrical connections Make sure that there is no watering or sprinkler system near or aimed at the water heater Most water sprinkling systems are connected to wells whose water contains minerals Sulphur and other aggressive contaminants These contaminants may promote corrosion and affect the ef...

Page 4: ...ections Minimum and maximum water flows IV CHLORINATORS BROMINATORS AND OTHERS P 8 9 Basic connections inline chlorinator or brominator Salt chlorinator Pressurized chlorinator or brominator Parallel connection V CONNECTION TO ELECTRICAL POWER P 9 VI MAINTENANCE P 10 Cleaning Winterizing Seasonal restart Water bypass VII REGULATOR P 11 12 VIII ALARM CODES P 13 IX TROUBLE SHOOTING P 14 X QUESTIONS ...

Page 5: ...possible to achieve yields of up to 600 or 700 under optimum conditions or a COP of between 6 and 7 In other words for every kilowatt that your heat pump uses it transfers up to 6 or 7 kilowatts between the air and the water in your pool This compares favorably with the 80 to 95 yield of a traditional gas oil or electric pool water heater However it is true that the performance of traditional pool...

Page 6: ...il 60 cm 2 feet 2 in front of all other surfaces 35 cm 14 inches 3 in front of the fan 120 cm 4 feet 4 in front of the service panel 60 cm 2 feet Objects should be placed as far away as possible from the area where air is evacuated OTHER RECOMMENDATIONS You should not install the device below a roof so that your heat pump becomes buried under snow or receives too much water if the roof is not fitt...

Page 7: ...ndenser An adjustable automatic bypass valve must be installed when a water pump of 2 HP or more is used to circulate the pool water Your water pump must be able to supply each heat pump with a water flow within the limits listed below MODEL MINIMUM IDEAL MAXIMUM Elite 50 65 57 l m 15 GPM US 170 l m 45 GPM US 170 l m 45 GPM US Elite 85 100 115 130 77 l m 20 GPM US 170 l m 45 GPM US 170 l m 45 GPM ...

Page 8: ...lation is not compliant to this rule SALT CHLORINATORS Salt chlorinators are made to be installed as inline chlorinators Therefore they must be installed as prescribed in the section above inline chlorinator or brominator PRESSURIZED CHLORINATOR OR BROMINATOR Pressurized chlorinators or brominators start by using a small quantity of water as it exits the filter then add chemicals and forward this ...

Page 9: ...lose to the heat pump in an accessible location Never open the electrical box without shutting off the power to all sources used for the operation of the heat pump If your heat pump has a pool pump control option remember to close the circuit breaker to this pump The spec sheet for the heat pump contains all the requirements for voltage and amps If the power cord is damaged it must be replaced by ...

Page 10: ...nse the condenser with tap water and drain the system with air pressure or vacuum 5 Cover the unit with a waterproof drop cloth if left outside all winter SEASONAL RESTART Before restarting your pool heat pump you must 1 Check and adjust the quality of the pool water 2 Make sure the breaker for the heat pump is turned off 3 Install the heat pump on a level surface and connect all plumbing 4 Clean ...

Page 11: ...hine is on 2 Water temperature setting a Press MODE key can switch HEAT circulating mode b Available no matter the machine is on or off Press HEAT light up c Press the key or to set water temperature The controller indicates flashing temp Press or to adjust to your desired water temp d 5 seconds later the controller display will back to the normal mode ...

Page 12: ... to set minute B Use or to adjust After adjusting press and water temperature will been seen 30 seconds later the controller display will be back to the normal mode C Press to set timer off When the indicator light is on and the time is flashing press again to set hour Use or to adjust before flashing stop press to set minute Use or to adjust After adjusting press and water temperature will been s...

Page 13: ...tection E 4 Over current 3 phase machine E 6 Compressor exhaust overload protection PP 1 Pool SPA heater sensor failure PP 2 Exhaust sensor failure PP 3 Coil pipe sensor failure PP 4 Intake pipe sensor failure PP 5 Air temp sensor failure PP 7 When the temperature 32 auto stop protection not Failure ...

Page 14: ...del or use more than one heat pump There is a lot of water under the device Normal runoff due to condensation Abnormal water leak No action required install a drain if necessary To determine whether this is a leak turn off the device until all condensation runoff has gone See if there is still water after 24 to 48 hours There is frost on the evaporator Outdoor temperature is cold Compressor works ...

Page 15: ...rmometer is often offset with respect to the graduations marked on the casing The thermometer displays temperatures higher or lower than the actual temperature of the water To measure the water temperature you can use an oral thermometer on which the graduations are more precise When pools have a bottom drain it is also possible that the pool heat pump displays a temperature of 1 to 2 degrees lowe...

Page 16: ...16 TTI FABRICATION Inc 684 Place Trans Canada Longueuil QC J4G 1P1 Canada www ttifab com www ttifab com ...

Reviews: