Elite Medical Multi-Mode Stimulator Instruction Manual Download Page 3

3

PACKAGE CONTENTS

Qty. (1) Multi-Mode Stimulator
Qty. (1) Patient Lead Wire Assembly
Qty. (1) Patient Instruction Manual
Qty. (1) Electrodes
Qty. (4) AA Alkaline Batteries
Qty. (1) Carrying and Storage Case

Optional Accessory

Qty. (1) AC Wall Adapter

 WARNING

 - Only use the supplied UL 

approved AC wall adapter. Use of any other 
type or brand of wall adapter may cause 
damage to the device.

Please read this manual carefully to become familiar with the 

before using it.

INTRODUCTION TO ELECTROTHERAPY

True interferential stimulation produces a different stimulation frequency through 

“interference” frequency that does change depending on the therapy protocol. When 
these two stimulation frequencies cross and “interfere” with each other within the 
body, the two frequencies subtract resulting in a third frequency, which is the thera-
peutic frequency “seen” by the targeted injury site. This phenomenon of subtracting 
two frequencies to create a third frequency is called “beating”.

The Multi-Mode Stimulator uses a carrier frequency of 4000Hz (hertz or cycles per 
second). At this frequency the skin impedance or resistance to the stimulation is at 

discomfort for the patient. Interferential stimulation is used to treat chronic and 
traumatic pain.

Depending on the pre-set therapy protocol selected, the interference frequency 
utilized by the Multi-Mode Stimulator may vary between 4001 to 4150Hz. The 

Summary of Contents for Multi-Mode Stimulator

Page 1: ...Carrier Frequency 4000 Hz Interference Frequency IF 4001 Hz to 4150 Hz Net Interferential Frequency Output Voltage 22 5 volts peak 0 45 volts peak to peak adjustable in 1 10 volt increments Output Cur...

Page 2: ...device KEEP THIS DEVICE OUT OF THE REACH OF CHILDREN Follow your physician s or therapist s instructions as to which therapy presets to use electrode placement and suggested amplitude levels TABLE OF...

Page 3: ...y that does change depending on the therapy protocol When these two stimulation frequencies cross and interfere with each other within the body the two frequencies subtract resulting in a third freque...

Page 4: ...an or therapist The amplitude or intensity of the treatment is patient controllable INTRODUCTION TO THE MULTI MODE STIMULATOR The Multi Mode Stimulator is a high quality advanced technology medical de...

Page 5: ...ns etc 7 Stimulation should not be applied over or in proximity to cancerous lesions 8 Stimulation should not be used whenever pain syndromes are undiagnosed until etiology is established PRECAUTIONS...

Page 6: ...Electronic monitoring equipment such as ECG monitors and alarms may not operate properly when interferential stimulation is in use in the management of pain patients 14 The Multi Mode Stimulator shou...

Page 7: ...tude Lockout To prevent an accidental increase or decrease of the treat ment amplitude intensity the Multi Mode Stimulator has an intra therapy amplitude lock feature Sixty seconds after the last incr...

Page 8: ...e quency for set dwell time then abrupt drop to base frequency repeat Relax and Contract Stimulation muscle stimulation Relax On for set dwell time at pre set base frequency and zero amplitude intensi...

Page 9: ...sec high 30 minutes 80 Hz 150 Hz 12 seconds Protocol Function Treatment Timer Base Freq High Freq Sweep Time Protocol 6 Full Sweep 6 seconds 30 minutes 1 Hz 150 Hz 6 seconds Protocol 7 Full Sweep 15 s...

Page 10: ...9 Dual MED Abrupt shift Ramped shift 15 minutes 15 minutes 1 Hz 80 Hz 10 Hz 150 Hz 6 seconds 6 seconds Protocol 10 Dual HIGH Abrupt shift Ramped shift 15 minutes 15 minutes 10 Hz 100 Hz 20 Hz 150 Hz 6...

Page 11: ...col 13 Muscle Simulation 20 minutes 50 Hz 50 Hz 6 sec ON 6 sec OFF Protocol 14 Muscle Simulation 20 minutes 50 Hz 50 Hz 5 sec ON 10 sec OFF Protocol 11 Protocol 12 Protocol 13 Protocol 14 3s 3s Contra...

Page 12: ...to the elec trodes and connect the opposite end to the therapy cable connector on the top of the stimulator 3 Turn the stimulator ON In a few moments you will see a screen asking you to make a therapy...

Page 13: ...your healthcare professional THERAPY STATUS SCREEN TYPICAL DISPLAY SCREENS SELECT PROTOCOL AMP LOCK PRESS ENTER TO UNLOCK THERAPY COMPLETE A090 P12 TR 07 Amplitude Setting A setting of 90 equals 9 vol...

Page 14: ...replacement lead wires Simulation Felt but the Device is Off Device is defective DO NOT USE please contact manufacturer for repair or replacement TYPICAL DISPLAY SCREENS Continued SYSTEM FAILURE CONTA...

Page 15: ...se Remove the batteries from the device during storage WARRANTY INFORMATION Elite Medical Supply of NY warrants the Multi Mode Stimulator against any defects in materials and workmanship for a period...

Page 16: ...Manufactured by Elite Medical Supply of NY LLC 1900 Ridge Road Suite 125 West Seneca NY 14224 866 712 0881 For questions regarding proper use or to request more supplies please contact Elite Medical S...