IX. Technical indicator
1.Generalspecification
- Display: LCD display,with maximum reading being 9999;
- Low battery alarm: See Table 1;
- Overranging indication: >20.0 G
Ω
” within the scope of insulation resistance;
- Automatic range function;
- Unit display: displaying the function and electric quantity unit symbol;
- Working condition:0°C~40°C/ relative humidity 85% or less;
- Storage condition: -20°C~60°C/ relative humidity 90% or less;
- Overall dimensions: mm (225L)X mm (103W)X mm(59D); Current consumption: about 500mA (in case of
maximum output 1000V) (about 10mAat ordinary times);
- It is designed and produced in strict compliance with safety standard IEC61010, overvoltage standard
(CAT IV 600V) and pollution grade II.
- Battery:AA 1.5V x6
- Battery life: a group of new alkaline batteries may last for more than 800 times of insulation resistance test
when positioning the selector switch in insulation resistance test position.(Test 1 M
Ω
at 1OOOV for 58
with an interval period of 258); a group of new alkaline batteries may last for more than 230 times of low
resistance test when positioning the selector switch in low resistance test position. (Test 1
Ω
for 58 with an
interval period of 25s);
- Automatic release of voltage;
- Backlight allows for operation in the dark environment.
- Red warning light;
- IP Level:IP 40
- Accessory:test wire,alligator clip, alkaline battery 1.5V (AA) x 6, user manual and a carrying case;
- Weight: 0.7kg (inclusive of battery).