45
Connect Two data wires to the loose connection
located near the power terminal:
7.
Dynamic Load Management (DLM) requires additional wiring be-
tween the Smart Energy Meter and the charging station. Use the
standard UTP Ethernet cable( or RS
-
485 twisted pair cable) for the
dynamic load management system:
22
23
Contacts 22/23 are ModBus communi-
cation contacts. Use the black color
wire for the 22 contact and the red color
wire for the 23 contact.