background image

4

!

• Flash systems store electrical energy in capacitors by applying high voltage.

• For your safety, never open or disassemble your flashes.

• Only an authorised service engineer should open or attempt to repair the units.

• For repairs, take them to your elinchrom agent.              

• Internal defect charge capacitors may explode whilst the unit is in use, never

   switch on a not proper working flash unit. 

Flash Tubes and Modelling lamps

• Flashtubes and modelling lamps in use are very hot!

• Never touch a flash tube or lamp before the unit cooled down and is disconnected from the mains.

• Do not fire flashes from short distance (less than 1m) directed to a person and avoid looking  

 

   directly into the flashlight!

• Keep distance to flammable materials.

• Keep generally distance to operating units.

Outdoors

• A thermal cut out protects internal electronic components. At high ambient temperatures or 

   after rapid or frequent use, the thermal cut out may interrupt the capacitor charge. The display

   will show “ER” . 

   After cooling down, the Generator restarts automatically. A Beep signal announces that 

   the unit is ready for operation, but note that it will only sound if the acoustic signal is switched on. 

• The Ranger RX power pack is designed to keep out humidity and dust. When it is possible, 

   sockets should be sealed with the supplied caps and please ensure the Battery Box is secure

   inside the Ranger RX housing.

• Never exchange the Battery under damp/humid conditions -  look for a dry and clean area!! 

• Avoid condensation related problems. 

• Take care that the battery is well locked

• Do not use in restricted areas (like hospitals, etc.)

• Do not use in explosive environnements

Due to strict security regulations, please note :

• Remove the 30 A fuse from the top side of the Battery Box, this desactivates 

   the internal «Lead-Gel-Battery»

• Remove the Battery Box from the Ranger RX unit and store separately in your luggage.

• The sealed lead acid battery confirms to the special provisions of UN No. 2800/238.

   Also this battery is satisfied with the special provisions A67 prescribed in 

   Non-Dangerous Goods Regulations by IATA

Travelling by Air (as well as any other transport option)

User Safety Information

Summary of Contents for Ranger RX

Page 1: ...English elinca sa switzerland www elinchrom com Operating Manual Elinca S A Ranger RX 01 06 2007 ENG 73300 Printed in Switzerland Battery Power Pack Ranger RX...

Page 2: ...onformity disposal and recycling CE marking 3 Safety notice and precaution 4 Before you start 5 Control Panel 6 Functions 7 8 Synchronisation Wireless Remote control and flash triggering 9 Change the...

Page 3: ...equirements of the Canadian Interference Causing Equipement Regulations These limits are designed to provide reasonable protection against harmful interference in a residential installation This equip...

Page 4: ...thatistheresultofnormaluse Anycomponentsnotreclaimed will be disposed of in a environmentally acceptable manner If you have any question on disposal please contact your local office or your local ELIN...

Page 5: ...After cooling down the Generator restarts automatically A Beep signal announces that the unit is ready for operation but note that it will only sound if the acoustic signal is switched on The Ranger...

Page 6: ...mmable explosive material Do not open the unit In the event of damage or apparent failure contact a repair service or any Elinca agent or email elinca elinca ch Always switch off unit before connectin...

Page 7: ...off with LED indicator Power 7 Power adjustment with ADF Auto Dump Function in 1 10 f stops 8 Power adjustment in 1 10 f stops 9 Digital power display 7 f stops in 1 10 positions Test 10 Open flash 11...

Page 8: ...reduce the sensitivity of the cell Photocell On Off 4 Slow Charge 3 The green LED indicates that the slow function is selected In slow mode approx 40 more flashes are available About 110 full power fl...

Page 9: ...reduction but please note that the consequent re charging will reduce the total number of available flashes N B Power indicator 6 flashes during charging and discharging Battery Status Indicator 13 Ap...

Page 10: ...ged Battery Box on a clean surface 6 Place the Ranger RX housing over the Battery Box 7 The Battery Box locates inside the Ranger RX housing 8 Press down on top of the Ranger RX pack to activate the l...

Page 11: ...curity cover 16 The 12 V 7Ah Gel Electrolyte Battery can be recharged from any charge level there is no Memory Effect The number of flashes may vary from Battery to Battery due to aging recycling spee...

Page 12: ...eech lock accepts all Elinchrom Prolinca accessories manufactured since 1974 The Ranger Free Lite S is a universal flashhead for all general studio and location work The Ranger Free Lite A head comes...

Page 13: ...n be used code 23046 Voltage across sync cable 5 Stabilisation V 1 Battery lead acid V Ah 12V 7Ah Battery recharge time approx h 3 Dimension cm 19 x 14 x 24 22 x 13 5 22 x 13 5 22 x 13 5 Weight kg 6 5...

Page 14: ...26371 Spots Zoom Spot 18 36 26481 Mini Spot 26420 Stands Stand 85 235cm 30101 Stand Master 109 385 cm 30149B Trigger accessories Universal Set 1x Transmitter 1x Universal Receiver and cables 19360 EL...

Page 15: ...e and address Ihr voller Name und redet an Votre nom complet et adresse Il suo nome pieno ed indirizza Su nombre y apellidos y dirige In case you cannot register your Elinchrom unit via internet pleas...

Page 16: ...www elinchrom com...

Reviews: