EN
26
CHARGE DURATION
The ELB 500 Battery charges to 90% in approximately 100
minutes. However, the charge duration may vary depending on the
battery’s initial state of charge.
CAUTION! The charge duration will be significantly longer if the
battery has been left completely discharged for weeks.
STATE OF CHARGE INDICATION
The battery includes a monitoring circuit which shows the available
capacity of the battery when the state of charge button is pressed.
CHARGING / DISCHARGING RECOMMENDATIONS
•
The Battery Pack can be used / discharged at ambient
temperatures from -10 °C to +60 °C.
•
The Battery Pack can be charged at ambient temperatures
from 0 °C to +45 °C. Charging is not recommended at
temperatures below 0 °C.
80 – 100 %
60 – 80 %
40 – 60 %
20 – 40 %
< 20 %