ELICA TROPIC IX/A/60 Instruction On Mounting And Use Manual Download Page 7

 

 

EN - Instruction on mounting and use  

Closely follow the instructions set out in this manual. 

All 

responsibility,  for any eventual inconveniences, damages or 
fires caused by not complying with the instructions in this 
manual, is declined.  
The extractor hood has been designed exclusively for 
domestic use. 

The hood can look different to that illustrated in the 
drawings in this booklet. The instructions for use, 
maintenance and installation, however, remain the same.   

It is important to conserve this booklet for consultation at 
any moment. In the case of sale, cession or move, make 
sure it is together with the product.   

Read the instructions carefully: there is important 
information about installation, use and safety.  

Do not carry out electrical or mechanical variations on the 
product or on the discharge conduits. 

Note: 

the elements marked with the symbol “(*)” are optional 

accessories supplied only with some models or elements to 
purchase, not supplied. 

 

  Caution 

WARNING! 

Do not connect the appliance to the mains until 

the installation is fully complete.  
Before any cleaning or maintenance operation, disconnect 
hood from the mains by removing the plug or disconnecting 
the mains electrical supply.  
Always wear work gloves for all installation and maintenance 
operations. 
The appliance is not intended for use by children or persons 
with impaired physical, sensorial or mental faculties, or if 
lacking in experience or knowledge, unless they are under 
supervision or have been trained in the use of the appliance 
by a person responsible for their safety. 
This appliance is designed to be operated by adults, children 
should be monitored to ensure that they do not play with the 
appliance. 
This appliance is designed to be operated by adults.  Children 
should not be allowed to tamper with the controls or play with 
the appliance. 
Never use the hood without effectively mounted grating! 
The hood must NEVER be used as a support surface unless 
specifically indicated. 
The premises where the appliance is installed must be 
sufficiently ventilated, when the kitchen hood is used together 
with other gas combustion devices or other fuels.  
The ducting system for this appliance must not be connected 
to any existing ventilation system which is being used for any 
other purpose such as discharging exhaust fumes from 
appliances burning gas or other fuels.  
The flaming of foods beneath the hood itself is severely 
prohibited. 
The use of exposed flames is detrimental to the filters and 
may cause a fire risk, and must therefore be avoided in all 
circumstances.  
Any frying must be done with care in order to make sure that 
the oil does not overheat and ignite. 

Accessible parts of the hood may became hot when used with 
cooking applicance. 
With regards to the technical and safety measures to be 
adopted for fume discharging it is important to closely follow 
the regulations provided by the authorised authorities. 
The hood must be regularly cleaned on both the inside and 
outside (AT LEAST ONCE A MONTH). 
This must be completed in accordance with the maintenance 
instructions provided in this manual). Failure to follow the 
instructions provided in this user guide regarding the cleaning 
of the hood and filters will lead to the risk of fires. 
Do not use or leave the hood without the lamp correctly 
mounted due to the possible risk of electric shocks. 
We will not accept any responsibility for any faults, damage or 
fires caused to the appliance as a result of the non-
observance of the instructions included in this manual. 
This appliance is marked according to the European directive 
2002/96/EC on Waste Electrical and Electronic Equipment 
(WEEE). By ensuring this product is disposed of correctly, you 
will help prevent potential negative consequences for the 
environment and human health, which could otherwise be 
caused by inappropriate waste handling of this product. 

The symbol 

 on the product, or on the documents 

accompanying the product, indicates that this appliance may 
not be treated as household waste. Instead it should be taken 
to the appropriate collection point for the recycling of electrical 
and electronic equipment. Disposal must be carried out in 
accordance with local environmental regulations for waste 
disposal. 

 

Use 

The hood is designed to be used either for exhausting or filter 
version. 
  

 Ducting version

 

In this case the fumes are conveyed outside by means of a 
special pipe connected with the connection ring located on top 
of the hood. 

Attention

! The exhausting pipe is not supplied and must be 

purchased apart. 
Diameter of the exhausting pipe must be equal to that of the 
connection ring. 
In the horizontal runs the exhausting pipe must be slightly 
slanted (about 10°) and directed upwards to vent the air easily 
from the room to the outside. 
Attention! If the hood is supplied with active charcoal filter, 
then it must be removed. 

Connect the hood and discharge holes on the walls with a 
diameter equivalent to the air outlet (connection flange). 
Using the tubes and discharge holes on walls with smaller 
dimensions will cause a diminution of the suction performance 

Summary of Contents for TROPIC IX/A/60

Page 1: ...EN Instruction on mounting and use ...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ...is detrimental to the filters and may cause a fire risk and must therefore be avoided in all circumstances Any frying must be done with care in order to make sure that the oil does not overheat and ignite Accessible parts of the hood may became hot when used with cooking applicance With regards to the technical and safety measures to be adopted for fume discharging it is important to closely follo...

Page 8: ...cal Service Mounting Expansion wall plugs are provided to secure the hood to most types of walls ceilings However a qualified technician must verify suitability of the materials in accordance with the type of wall ceiling The wall ceiling must be strong enough to take the weight of the hood Do not tile grout or silicone this appliance to the wall Surface mounting only Operation Use the high suctio...

Page 9: ...ely for 2 Deactivation of carbon filter signalling Set the hood to OFF and keep keys 2 and 3 pressed contemporaneously for 3 Number 1 flashes for 2 Temperature Alarm The hood is equipped with a temperature sensor which activates the motor at speed 3 in case the temperature in the display zone is too high The alarm condition is indicated by the display with the letter t flashing This condition rema...

Page 10: ...ng capacity To remove the grease filter pull the spring release handle Charcoal filter filter version only Fig 23 It absorbs unpleasant odours caused by cooking The saturation of the activated charcoal occurs after more or less prolonged use depending on the type of cooking and the regularity of cleaning of the grease filter In any case it is necessary to replace the cartridge at least every four ...