ELICA TROPIC IX/A/60 Instruction On Mounting And Use Manual Download Page 10

 

Maintenance 

ATTENTION! 

Before performing any maintenance operation, 

isolate the hood from the electrical supply by switching off at 
the connector and removing the connector fuse.  
Or if the appliance has been connected through a plug and 
socket, then the plug must be removed from the socket. 

 

Cleaning 

The cooker hood should be cleaned regularly (at least with the 
same frequency with which you carry out maintenance of the 
fat filters) internally and externally.  Clean using the cloth 
dampened with neutral liquid detergent. Do not use abrasive 
products. 

DO NOT USE ALCOHOL!

 

WARNING: 

Failure to carry out the basic cleaning 

recommendations of the cooker hood and replacement of the 
filters may cause fire risks.  
Therefore, we recommend oserving these instructions. 
The manufacturer declines all responsibility for any damage to 
the motor or any fire damage linked to inappropriate 
maintenance or failure to observe the above safety 
recommendations. 

 

Grease filter 

Fig. 9-24 
Traps cooking grease particles. 

 

This must be cleaned once a month (or when the filter 
saturation indication system – if envisaged on the model in 
possession – indicates this necessity)  using non aggressive 
detergents, either by hand or in the dishwasher, which must 
be set to a low temperature and a short cycle. 
When washed in a dishwasher, the grease filter may discolour 
slightly, but this does not affect its filtering capacity. 
To remove the grease filter, pull the spring release handle. 

 

Charcoal filter (filter version only) 

Fig. 23 
It absorbs unpleasant odours caused by cooking. 

The saturation of the activated charcoal occurs after more or 
less prolonged use, depending on the type of cooking and the 

regularity of cleaning of the grease filter. 
In any case it is necessary to replace the cartridge at least 
every four mounths (or when the filter saturation indication 
system – if envisaged on the model in possession – indicates 
this necessity). 
Remove the grease filters. 
Fit the charcoalfilters over the motor. 
Align the 

pins R

 

on the cowl with the 

slots S

, then turn the 

filter clockwise until it locks in place. 
Reverse the above procedure to remove the charcoal filters. 
Refit the grease filters. 

 

Replacing lamps 

Fig. 25 

Disconnect the hood from the electricity. 

Warning! 

Prior to touching the light bulbs ensure they are 

cooled down. 
  

Model with halogen light bulbs.

 

1.

  Using a flat head screwdriver or equivalent tool, carefully 

pry loose the light cover.   

2.

  Remove the damaged light and replace with a new 

12 

Volt, 20 Watt 

(Maximum) halogen light made for a

 G-4 

base

 SUITABLE FOR USE IN OPEN LUMINAIRES.  

Follow package directions and do not touch new light 
with bare hands. 

3.

  Reinstall the light  cover. (it will snap shut). 

 

Model with incandescent light bulbs:

 

1.

  Remove the grease filters . 

2.

  Replace faulty bulbs, always using new bulbs of 

max. 40 

W (E14). 

3.

  Refit the grease filters. 

  
If the lights do not work, make sure that the lamps are fitted 
properly into their housings before you call for technical 
assistance. 
 
 

Summary of Contents for TROPIC IX/A/60

Page 1: ...EN Instruction on mounting and use ...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ...is detrimental to the filters and may cause a fire risk and must therefore be avoided in all circumstances Any frying must be done with care in order to make sure that the oil does not overheat and ignite Accessible parts of the hood may became hot when used with cooking applicance With regards to the technical and safety measures to be adopted for fume discharging it is important to closely follo...

Page 8: ...cal Service Mounting Expansion wall plugs are provided to secure the hood to most types of walls ceilings However a qualified technician must verify suitability of the materials in accordance with the type of wall ceiling The wall ceiling must be strong enough to take the weight of the hood Do not tile grout or silicone this appliance to the wall Surface mounting only Operation Use the high suctio...

Page 9: ...ely for 2 Deactivation of carbon filter signalling Set the hood to OFF and keep keys 2 and 3 pressed contemporaneously for 3 Number 1 flashes for 2 Temperature Alarm The hood is equipped with a temperature sensor which activates the motor at speed 3 in case the temperature in the display zone is too high The alarm condition is indicated by the display with the letter t flashing This condition rema...

Page 10: ...ng capacity To remove the grease filter pull the spring release handle Charcoal filter filter version only Fig 23 It absorbs unpleasant odours caused by cooking The saturation of the activated charcoal occurs after more or less prolonged use depending on the type of cooking and the regularity of cleaning of the grease filter In any case it is necessary to replace the cartridge at least every four ...