Electrical Connection
I
WARNING
ELECTRICAL SHOCK HAZARD.
I
WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK.
1
Disconnect power.
2
Remove terminal box cover.
3
Remove the knockout in the terminal box cover and install
a UL listed or CSA approved
1
⁄
2
” strain relief.
B
A.
Knockout
B.
Junction box cover
A
4
Run home power supply cable through strain relief, into
terminal box.
A
B
C
D
E
F
A.
Home power supply cable
B.
UL listed or CSA approved
strain relief
C.
Black wires
D.
UL listed wire connectors
E.
White wires
F.
Green (or bare) and
yellow-green ground wires
5
Use UL listed wire connectors and connect black wires
(C) together.
6
Use UL listed wire connectors and connect white wires (E)
together.
I
WARNING
ELECTRICAL SHOCK HAZARD.
I
WARNING
ELECTRICALLY GROUND BLOWER.
CONNECT GROUND WIRE TO GREEN AND YELLOW
GROUND WIRE IN TERMINAL BOX. FAILURE TO DO SO CAN
RESULT IN DEATH OR ELECTRICAL SHOCK.
7
Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box
using UL listed wire connectors.
8
Tighten strain relief screw.
9
Install terminal box cover.
10
Check that all light bulbs are secure in their sockets.
11
Reconnect power.
Install duct covers
• When using both upper and lower vent covers, push lower
cover down onto hood and lift upper cover to ceiling and
install with two mounting screws.
NOTE
: For vented installations, the upper vent cover may be
reversed to hide slots.
D
C
C
A
B
A. Upper vent cover
B. Lower vent cover
C. 4 x 8 mm screws
D. Bracket
• Secure the bottom of the duct with 2 - 4 x 8 mm screws.