background image

 
 
 
 

 

 

11

11. Pin-Assignment 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

                                                                   Inverted signals are marked with ’ 

 

Connector ST1  
(standard encoders):  

 
  1: GND (output) 
  2: + 5 VDC/24 VDC (output) 
  3: Channel A 
  4: Channel B 
 5: 

Screen/shield/PE 

  6: Channel A’ 
  7: Channel B’ 
  8: Channel Z’ 
  9: Channel Z 
 

Connector ST2 
(supply):

 

1: Screen/shield/PE 
2: GND (Input) 
3: + 24VDC (Input) 

  4: Tolerance window input 
  5: Datum input 
  6: Reset input 
 
 

Connector ST5 
(RS-232 PC-interface) 
 
 

 

Connector ST3  
(absolute signals, relays, analog-output): 

 

1:  Screen/shield/PE 
2:  GND (Encoder supply) 
3:  + 24VDC (Encoder supply out)  

    4:  RS422_RX’                           
    5:  RS422_RX                             
    6:  RS422_RS485_TX’ 
    7:  RS422_RS485_TX 

  8:  Analog-input   0… 10 VDC or 0… 20 mA 

    9:  Analog-output 0... 10 VDC 

    10:  

Analog-output 0 (4)... 20 mA 

    11:  

Relays_1_A 

   12: Relays_1_B 
   13: Relays_2_A 
   14: Relays_2_B 
    

Connector ST4  
(differential encoders): 

 

  1: GND (Encoder supply out) 
  2: + 5VDC (Encoder supply out) 
  3: Channel A 
  4: Channel B 
  5: GND (output) 
  6: Channel A’ 
  7: Channel B’ 
  8: Channel Z 
  9: Channel Z’

 

Connector ST5 
 
 
Connector ST4 
 
 
Connector ST2 
 
 
Connector ST1 
 
 
Connector ST3 
 

Example rear with full configuration

Summary of Contents for Z58-SN004

Page 1: ...encoders lockable to inkremental or absolute encoders FMAX FEMAX EMAX approved standard functions e g pulse scaling multi edge counter Inch mm switch over three external inputs 24 V serial interface...

Page 2: ...set 7 6 2 Absolute Incremental mode 7 6 3 Additional tool offset 7 6 4 Set to datum value 7 6 5 How to activate the tolerance window 7 7 TEACHING PROCEDURE 8 8 INFORMATION S ABOUT PULSE SCALING FACTOR...

Page 3: ...also as a pure pulse counter e g quantities Z58 is a universal device which can work with output signals of all standard linear encoders from ELGO An optional SSI interface allows to evaluate additio...

Page 4: ...in normal mode 3 Operation modes Basically two modes are selectable 1 Programming mode setting parameters 2 Normal mode Counting mode Status Relays 1 Option lights up if activated Status Relays 2 Opti...

Page 5: ...ront lateral keys 0 active 1 not active 1 1 0 P 06 Edge multiplier 0 x 1 1 x 2 2 x 4 0 1 2 0 P 07 Selection of measuring system 0 Encoder 1 RS422 Encoder 2 EMAX FEMAX 3 FMAX 0 1 2 3 0 P 08 Pulse scali...

Page 6: ...over to the display if Button will be pressed or the external reference input will be closed P10 Adjustable tool offset This value will be added to the actual value if Button is pressed or the extern...

Page 7: ...play will be set to zero The further counting proce dure starts from this point then After renewed pressing of Incr Abs Button the unit switches back to absolute measuring mode 6 3 Additional tool off...

Page 8: ...d press Button then The display shows 3 Now move the FMAX sensor to the desired offset and press Button then The display shows 4 With releasing the Button the system is calibrated and the display show...

Page 9: ...ame time Tool offset Undo Abs Incr switch over between entire and relative measurement Change to Programming mode for 3 sec at the same time Programming mode Parameter step up Select decade Increase d...

Page 10: ...nd STX i ETX Example 02h 69h 03h Answer e g 9712 3 decimal bzw 0001 7B63 hexadecimal STX 8 Byte Datas CRC ETX 02h 36h 33h 37h 42h 30h 31h 30h 30h A3h 03h Please note The datas are transmitted in hexad...

Page 11: ...solute signals relays analog output 1 Screen shield PE 2 GND Encoder supply 3 24VDC Encoder supply out 4 RS422_RX 5 RS422_RX 6 RS422_RS485_TX 7 RS422_RS485_TX 8 Analog input 0 10 VDC or 0 20 mA 9 Anal...

Page 12: ...led state Protection class rear IP00 Analog input Option 10 Bit A D Converter 0 10 VDC oder 0 20 mA Analog output Option 12 Bit D A Converter 0 10 VDC Imax 5 mA or 0 4 20 mA Rmax 200 2 Relay outputs O...

Page 13: ...output level PNP 100 KHz 2 A A B B Z Z 24 VDC Encoder supply 5 V TTL PNP 100 KHz 3 A A B B Z Z 5 VDC Encoder supply 5 V TTL PNP 100 KHz 4 Modulated for connection with ELGO FMAX linear encoder 5 Modu...

Page 14: ...our products therefore we keep all rights reserved for any technical modifications without any notice ELGO Electric does not assume any liability for possible errors or mistakes The guarantee period...

Reviews: