background image

 
 
 
 

 

 

17

 

16. Liability exclusion / Guarantee 

We have checked the contents of this instruction manual carefully, to the best of our knowl-

edge and belief for conformity with the described hardware and software. Nevertheless errors, 

mistakes or deviations can not be excluded, therefore we do not guarantee complete confor-

mity. Necessary corrections will be included in the subsequent editions.  

We appreciate your ideas and improvement suggestions very much. Reprint, duplication and 

translation, even in extracts, are only allowed with a written authorization by the company 

ELGO Electronic GmbH & Co. KG. We constantly strive for improving our products, therefore we 

keep all rights reserved for any technical modifications without any notice. ELGO Electronic 

GmbH & Co. KG does not assume any liability for possible errors or mistakes. 

 

The guarantee period is one calendar year from the date of delivery and includes the delivered 

unit with all components. ELGO Electronic GmbH &  Co. KG will at its option replace or repair 

without charge defects at the unit or the included parts, verifiable caused by faulty manufac-

turing and/or material in spite of proper handling and compliance to the instruction manual.  

 

Damages verifiably not caused by ELGO Electronic GmbH & Co. KG and due to improper han-

dling are excluded from any guarantee e.g. by applying faulty voltage, diffusion of liquid into 

the interior of the engine, using force, scratching the surface, 

chemical influences etc.!

  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Dok.- Nr. 799000082                 
Z58-000-E_07-10                  
Subject to modifications - 

©

  2010 - ELGO Electronic GmbH & Co. KG

 

Summary of Contents for Z58-6 Series

Page 1: ...inkremental or absolute encoders FMAX FEMAX EMAX approved standard functions e g pulse scaling multi edge counter Inch mm switch over three external inputs 24 V serial interface RS 232 analog input 0...

Page 2: ...fset 7 6 4 Set to datum value 7 7 TEACHING PROCEDURE 8 8 INFORMATION S ABOUT PULSE SCALING FACTOR 8 9 LIST OF MOST IMPORTANT KEY FUNCTIONS 9 10 SERIAL INTERFACE 10 10 1 Commands 10 11 ERROR NUMBERS 10...

Page 3: ...ng of actual positions Z58 is a universal device which can work with output signals of all standard linear encoders from ELGO An optional SSI interface allows to evaluate additionally conventional abs...

Page 4: ...l mode 3 Operation modes Basically two modes are selectable 1 Programming mode setting parameters 2 Normal mode Counting mode Status Relays 2 Option shines if activated Tool Offset shines if activated...

Page 5: ...ot active 0 1 0 P 05 Front lateral keys 0 active 1 not active 1 1 0000 P 06 Edge multiplier 0 x 1 1 x 2 2 x 4 0 1 2 0 P 07 Selection of measuring system 0 Encoder 1 RS422 Encoder 2 EMAX FEMAX 3 FMAX 0...

Page 6: ...or the external reference input will be closed P10 Adjustable tool offset This value will be added to the actual value if Button is pressed or the external tool offset input will be closed P11 Saw bl...

Page 7: ...he display from absolute resp entire to incremental resp relative measurement After switch over to the relative measuring incremental mode the display will be set to zero The further counting proce du...

Page 8: ...d press Button then The display shows 3 Now move the FMAX sensor to the desired offset and press Button then The display shows 4 With releasing the Button the system is calibrated and the display show...

Page 9: ...nge reference value P09 Back to normal Operation mode press for 3 sec Tool offset Undo Abs Incr switch over between entire and relative measurement Change to Programming mode for 3 sec at the same tim...

Page 10: ...h 69h 03h Answer e g 9712 3 decimal bzw 0001 7B63 hexadecimal STX 8 Byte Datas CRC ETX 02h 36h 33h 37h 42h 30h 31h 30h 30h A3h 03h Please note The datas are transmitted in hexadecimal ASCII Code start...

Page 11: ...bsolute signals relays analog output 1 Screen shield PE 2 GND Encoder supply 3 24VDC 5VDC Encoder supply out 4 RS422_RX 5 RS422_RX 6 RS422_RS485_TX 7 RS422_RS485_TX 8 Analog input 0 10 VDC or 0 20 mA...

Page 12: ...t 0 10 V G Analog output 0 20 mA H Analog output 4 20 mA Basically the AC variant is offered for replacement of the parent Z54 type Owing to place require ment the functions described above are not re...

Page 13: ...SSI Interface Standard SSI on request as absolute measuring input Protection class front IP43 installed state Protection class rear IP00 Analog input Option 10 Bit A D Converter 0 10 VDC oder 0 20 mA...

Page 14: ...14 14 Dimensions 14 1 Measurements of the panel housing in mm Install depth with screw terminals 78 mm Install depth with SUB D connector 115 mm 66 72 91 5 96 64 5 5 5...

Page 15: ...15 14 2 Measurements of the built on housing Option AG in mm Depth inclusive power plug 160 mm Side view Screw length max 15 mm Side view...

Page 16: ...z 4 Modulated for connection with ELGO FMAX linear encoder 5 Modulated for connection with ELGO EMAX linear encoder 6 SSI interface on request 7 A B Z 5 VDC Encoder supply 5 V TTL output level PNP 100...

Page 17: ...ed for any technical modifications without any notice ELGO Electronic GmbH Co KG does not assume any liability for possible errors or mistakes The guarantee period is one calendar year from the date o...

Reviews: