Installation and First Start-Up
- 13 -
Figure 6: Mounting direction of EMAX-RO Sensor to Magnetic Ring
5.2.3
Offset
After the installation of the magnetic tape and the measuring system (EMAX-RO) a value is transmitted by the
interface. Because this value does not conform to the machine zero point, an offset should to be deposited at
the controller side.
NOTE!
The offset should be arranged at any change from measurement system (sensor head) or
magnetic ring.
5.2.4
Activation of the device
The device starts automatically after operation voltage application. Depending on the interface may be addi-
tional steps required to activate the EMAX-RO.
EMAX-RO Sensor
Distance detection via
LED
Symbolic illustration
Fine interpolation track
Direction arrow
for assembly
Absolute track