6. Hints for installation and Operation  

 

Hints for Operation in Electrical panels 

This position indicator is designed and constructed for use in arduous industrial applications and as 
immune to electrical interference as possible. Care should however be taken when fitting electronic 

equipment into machinery. 
 
1. Electronic units should be mounted away from inductive and capacitate interference. 

 
2. Protect against overvoltage. 
 

3. Protect against over temperature. 
 
4. Run low voltage cables separate to high voltage/high power cables. 

 

5. Screen encoder cables and input signal cables. Tie screen to zero (terminal 1) at controller; 

leave insulated at other end. 

 
6. Suppress all relays, contractors,  solenoids, brakes and other coils in cabinet and on machine. Fit 

diodes across dc coils. Fit 0,1 µF + 100 

 across ac coils. Failure to follow the above logical 

simple instructions could lead to maloperation of the electronic unit. 

 

Hints on mounting the Tape MB20.50 

Use double-sided sticky tape (or other adhesive). It is important that the base tape 

B

 on  the 

bonded rubber tape 

A

 are firmly fixed to the machine bed. The separately delivered tape 

C

 is only 

for mechanical protection. The Sensor operates with a gap of 0.1 to 2.0 mm from the Tape C. The 

tape can be mounted at any angle. 

 

 
 

Sensor side

Mounting side

C

A

B

1,8mm

 

 
 
 
 

 
 
 

 
 

8

Summary of Contents for Z20-SN105-024

Page 1: ...stem ELGO sensor MS20 60 and magnetic tape MB20 50 With sign 5 digits pulse factor Programmable decimal point Digital brightness control SERIE Z20 SN105 024 Z20 005 with enable of parameter settings b...

Page 2: ...ic tape MB 20 50 5 2 Sensor MS 20 60 6 5 PARAMETER SETTING 7 Registers 7 Programming example 7 6 HINTS FOR INSTALLATION AND OPERATION 8 Hints for Operation in Electrical panels 8 Hints on mounting the...

Page 3: ...10 sec Rate 2 at 10 HZ for 10 sec Rate 3 at 1000 HZ as long as pushbutton are depressed It is necessary shortly before the desired value is reached to release the button and reactivate so as to approa...

Page 4: ...ent will operate satisfactorily with a measuring gap of 0 1 to 2 0 mm Protection Class The magnetic measuring system offers the greatest protection against hostile environments Sensor and tape are pro...

Page 5: ...nical damages and is at the same time a magnetic short circuit This increases significantly the functional security under extreme magnetic influences A and B are already factory bonded C To keep the f...

Page 6: ...ap between sensor and measuring tape must not be larger than 0 1 2 0 mm Sensor cable length signal processing Z20 005 is a combination of the indicator and the sensor The sensor wire is available in t...

Page 7: ...3 07 Sign 0 active 1 inactive 08 Pulse factor 0 0001 9 9999 09 Datum value 0 0001 9 9999 14 Display brightness Set 0 9 0 9 dark 16 Enable of Par 09 0 Nr 09 disabled 2 Nr 09 enabled Programming example...

Page 8: ...es and input signal cables Tie screen to zero terminal 1 at controller leave insulated at other end 6 Suppress all relays contractors solenoids brakes and other coils in cabinet and on machine Fit dio...

Page 9: ...ose Also included is a double side adhesive strip Available in rolls from 0 5 to 25 m in length Length 0 5 to 25 m Repeat accuracy 0 01 mm Accuracy at 20 C in mm 0 025 0 02 x L L Length in m Temperatu...

Page 10: ...8 Dimensions Cut out Side view External dimensions 66 mm 44 mm 48mm 62mm 57mm 77mm F RESET SET ELECTRIC ELGO 48mm 72mm 10...

Page 11: ...ing level by hardware link Supply voltage 024 24 V DC AC 10 Encoder input 9 Magnetic sensor 0 01 mm resolution Special Features No options at the moment Accessories Magnetic tape MB 20 50 25 0 Increme...

Page 12: ...keep all rights reserved for any technical modifications without any notice ELGO Electric does not assume any liability for possible errors or mistakes The guarantee period is one calendar year EC Dir...

Reviews: