background image

 

Simple Mounting 
 

The tape is simple to attach to the machine (e.g. by means of double sided sticky tape). Due to its 
high flexibility it can cope with uneven surfaces ore radii without affecting accuracy. A second steel 

tape is fitted on top of the magnetic tape, to protect it. The equipment will operate satisfactorily 
with a measuring gap of 0.1 to 2.0 mm. 
 

Protection Class 
 

The magnetic measuring system offers the greatest protection against hostile environments.  

Sensor and tape are protected to IP65. 

 

Connections 

 
Connections are by means of simple plug in connectors. This connector are readily removable and 
easily wired. 

 
 

 
 

 

+ 15… 30 VDC 

RESET

SET

Power Supply  

Schalter 

- 0  V  (GND)     

 

1    2    3    4    5    6    7    8   9  10 

Connector  for Sensor

Parameter settings: 

Jumper   enabled 

no jumper   disabled

 

 
 
 

 
 

4

Summary of Contents for Z20-SN105-024

Page 1: ...stem ELGO sensor MS20 60 and magnetic tape MB20 50 With sign 5 digits pulse factor Programmable decimal point Digital brightness control SERIE Z20 SN105 024 Z20 005 with enable of parameter settings b...

Page 2: ...ic tape MB 20 50 5 2 Sensor MS 20 60 6 5 PARAMETER SETTING 7 Registers 7 Programming example 7 6 HINTS FOR INSTALLATION AND OPERATION 8 Hints for Operation in Electrical panels 8 Hints on mounting the...

Page 3: ...10 sec Rate 2 at 10 HZ for 10 sec Rate 3 at 1000 HZ as long as pushbutton are depressed It is necessary shortly before the desired value is reached to release the button and reactivate so as to approa...

Page 4: ...ent will operate satisfactorily with a measuring gap of 0 1 to 2 0 mm Protection Class The magnetic measuring system offers the greatest protection against hostile environments Sensor and tape are pro...

Page 5: ...nical damages and is at the same time a magnetic short circuit This increases significantly the functional security under extreme magnetic influences A and B are already factory bonded C To keep the f...

Page 6: ...ap between sensor and measuring tape must not be larger than 0 1 2 0 mm Sensor cable length signal processing Z20 005 is a combination of the indicator and the sensor The sensor wire is available in t...

Page 7: ...3 07 Sign 0 active 1 inactive 08 Pulse factor 0 0001 9 9999 09 Datum value 0 0001 9 9999 14 Display brightness Set 0 9 0 9 dark 16 Enable of Par 09 0 Nr 09 disabled 2 Nr 09 enabled Programming example...

Page 8: ...es and input signal cables Tie screen to zero terminal 1 at controller leave insulated at other end 6 Suppress all relays contractors solenoids brakes and other coils in cabinet and on machine Fit dio...

Page 9: ...ose Also included is a double side adhesive strip Available in rolls from 0 5 to 25 m in length Length 0 5 to 25 m Repeat accuracy 0 01 mm Accuracy at 20 C in mm 0 025 0 02 x L L Length in m Temperatu...

Page 10: ...8 Dimensions Cut out Side view External dimensions 66 mm 44 mm 48mm 62mm 57mm 77mm F RESET SET ELECTRIC ELGO 48mm 72mm 10...

Page 11: ...ing level by hardware link Supply voltage 024 24 V DC AC 10 Encoder input 9 Magnetic sensor 0 01 mm resolution Special Features No options at the moment Accessories Magnetic tape MB 20 50 25 0 Increme...

Page 12: ...keep all rights reserved for any technical modifications without any notice ELGO Electric does not assume any liability for possible errors or mistakes The guarantee period is one calendar year EC Dir...

Reviews: