background image

 
 
 
 

11 

 

Processing note for sticking 

The provided sticky tapes stick well on clean, dry and plain surfaces. The more pollution exists 

the more proper the surface has to be. A surface roughness of R

a

 <= 3,2 (R

z

 <= 25 / N8) is rec-

ommendable. Typical solvent for cleaning surfaces are a 50/50 - isopropyl-alcohol / water mix-

ture or heptane. The surfaces of materials as copper, brass etc. should be sealed to avoid an 

oxidation. The stability of the adhesion is directly depending on the contact, which the adhesive 

develops to the stuck surfaces. A high pressure results in a good surface contact. 

 

The optimal sticking temperature is b 21°C and 38°C.   

 

Avoid colder sticking surfaces than + 10 °C, because in this case the adhesive becomes to hard 

and perhaps a sufficient immediate adhesion is hardly to achieve. After proper sticking the sta-

bility of the connection is ensured also when the temperature is below zero. The final tackiness 

of a sticking is from experience reached after approximately 72 hours (at + 21 °C). For sticking 

use only the provided sticky tape.  

Resistance to chemicals of the magnetic tape  

The magnetic tape shows 

no or only small effects

 when contacting permanently the following 

materials after 2 to 5 years:

 

Formic acid, Glycerol 93°C, Linseed oil, Soy beans oil, Cotton seed 

oil, N-hexane, Lactic acid, Formaldehyde 40%, Isooctane, Petroleum. 

Poor to medium effects

 result when contacting permanently the following materials after ap-

proximately 1 year:

 

Acetone, Gasoline, Acetic acid 30%, Olein acid, Acetylene, Steam, Acetic 

acid, pure Acetic acid, Sea water, Ammonia, Acetic acid 20%, Isopropyl ether, Stearic acid 70°C 

anhydrous, Kerosene. 

Strong effects result

 when contacting permanently the following materials after 1 to 5 

months:

 

Benzene, Nitric acid 70%, Turpentine, Toluene, Lacquer solvent, Nitric acid red and 

Vitriolic, Carbon Tetrachloride, Trichloroethane, Nitrobenzene, Hydrochloric acid 37% and 93°C, 

Tetrahydrofuran, Xylene.  

Sticking and cutting 

 

Attention! 

When sticking the magnetic tape pay attention to the marks on the mag-

netic tape. A faulty installation delivers incorrect values. An already stuck magnetic 

tape is ruined after removing and can't be used again. Observe also the counting 

direction of the measuring system. 

 

The magnetic tape and the covering band must be cut to the exact length before sticking: 

 

        

Magnetic tape length = measuring 0.1 m 

 

Preferably the magnetic tape should be stuck into a nut or aligned to an edge.  

 

Procedure for sticking: 

1. The magnetic tape is already factory bonded with the steel band, in between is a double sided 

sticky tape. Stick the provided sticky tape onto the carrier side (= steel band).  

2. Now adjust the magnetic tape and stick it onto the surface. The best way to stick the mag-

netic tape is to do it in two steps. Remove the first half of the adhesive film from the sticky tape 

and stick it, then do the rest length.  

3. Then stick the sticky tape onto the covering band. It is not important on which side of the 

covering band the sticky tape is stuck on. 

4. 

Stick the covering band onto the visible brown magnetic rubber tape

 

 

Summary of Contents for AZ16I series

Page 1: ...ermanent retention of all data and settings Reserve energy up to 4 years AUTO POWER OFF function with adjustable switch on time Switch over for absolute incremental mode Millimeters or Inches operation Fraction views in the Inch mode possible User friendly menu levels Completely guided by magnetic tape guidance rail Key can be enabled or disabled individually Adjustable reference value and 3 tool ...

Page 2: ...N OPERATION 5 5 1 Initial operation 5 5 1 1 Detection of measuring direction 5 5 1 2 Referencing 5 5 3 Parameter settings 7 6 BATTERY CHANGE 9 7 MAGNETIC TAPE 10 Handling 10 Processing note for sticking 11 Resistance to chemicals of the magnetic tape 11 Sticking and cutting 11 7 TECHNICAL SPECIFICATIONS PRELIMINARY 12 9 TYPE DESIGNATION 13 10 LIABILITY EXCLUSION GUARANTEE 14 ...

Page 3: ...ostumer him self The guideway for the rail is located on the rear of the indicator unit On request the system can be supplied also without guidance and guide rail then the user must provide and guarantee for a suitable mechanical guiding system It must be ensured that the sensor integrated in the indicator keeps the correct distance 0 1 5 mm along the whole measuring distance coplanar to the magne...

Page 4: ...e rail is multipart supplied since for transport technical reasons only a maximum length of 2 m are possible The single rail parts still have no mounting holes These must done by the user and also be fastened align at a suitable place then The magnetic tape must be inserted after arraying the rail parts into the slot of the rails and stuck together with the special sticky tape attached at the magn...

Page 5: ...6I unit shows always the absolute value of the magnetic tape and should be calibrated to the zero point at one time The reference value default setting in reg ister P09 is 0 To assign a zero point to an arbitrary position move to the desired zero point and press the buttons F Set together Reference value Alternatively an arbitrary value can be entered in P09 to set a demanded ref erence measuremen...

Page 6: ...hes back to absolute measurement and the display shows the real absolute value again and ABS also Incr Abs Reference value F Set By pressing F Set together the display sets to the reference value deposited in register P09 Switch back from the sleep mode F The unit switches into the sleep mode after completion of the adjustable time in register P04 if there are no changes in the display value and n...

Page 7: ...using the Incr Abs button F 5 Press F to select the next parameter Repeat No 2 4 for the next parameter F 6 Press F for 3 seconds The display shows the actual value again F 2 Press button F The appropriate parameter value appears in the display 3 sec 3 sec Default settings If during battery insertion the button Incr Abs is pressed the unit sets all registers to the default settings Incr Abs ...

Page 8: ...ve direction disabled Arrow symbol for positive direction enabled 0 1 LCD in standby mode disabled LCD in standby mode enabled Display OFF and battery condition P 03 Decimal place default setting 1 X 0 3 for mm operation only P 05 keyboard interlock default setting 111 X X X 0 1 button Set disabled button Set enabled 0 1 button Incr Abs disabled button Incr Abs enabled 0 1 button disabled button e...

Page 9: ...999 999 Inch 9999 999 Inch P 12 tool offset 3 default setting 30 0 mm 0 300 Inch 999999 9 mm 999999 9 mm 9999 999 Inch 9999 999 Inch P 99 Software version Indicates the software version of the unit 6 Battery change Remove the back wall of the display unit to change the batteries commercial battery type size AA 1 5 V with a standard unit internal battery case All values and settings remains in case...

Page 10: ...ic tape from extreme external magnetic influences To reach a complete adhesion between the several materials a special sticky tape is used Pos 2 Pos 4 Pos 6 Pos 1 Covering band Pos 2 Sticky tape Pos 3 Magnetic rubber tape Pos 4 Sticky tape Pos 5 Steel band Pos 6 Sticky tape Factory bonded Picture 1 Components of the magnetic tape Handling To avoid tension in the magnetic tape don t tuck or twist i...

Page 11: ... proximately 1 year Acetone Gasoline Acetic acid 30 Olein acid Acetylene Steam Acetic acid pure Acetic acid Sea water Ammonia Acetic acid 20 Isopropyl ether Stearic acid 70 C anhydrous Kerosene Strong effects result when contacting permanently the following materials after 1 to 5 months Benzene Nitric acid 70 Turpentine Toluene Lacquer solvent Nitric acid red and Vitriolic Carbon Tetrachloride Tri...

Page 12: ...racter of Measurement Linear no rotative movements possible LCD Display 6 Decades height 8 mm with battery condition signs and symbols Keypad Membrane keypad Operating temperature 5 50 C Stock temperature 0 70 C Humidity Not condensing max 80 Altitude max 2000 m above sea level Protection class IP 43 Outer dimensions W x H 96 x 72 mm Cut out W x H 93 x 67 mm Depth install depth 32 0 mm total depth...

Page 13: ...il for AZ16I Magnetic tape length to order Effective measuring length 100 mm A With effective measuring distances smaller than 1 885 m the guide rail is already assembled with the magnetic tape Please note Owing to the mounting hole the rail is 15 mm s longer B With effective measuring distances larger than 1 885 m several guide rail parts according to the total length and a separately magnetic ta...

Page 14: ...re we keep all rights reserved for any technical modifications without any notice ELGO Electric does not assume any liability for possible errors or mistakes The guarantee period is to two calendar years from the date of delivery and includes the deliv ered unit with all its components ELGO Electric GmbH will at its option replace or repair without charge defects at the unit or the included parts ...

Reviews: