AZ16I-000-E_10-06.doc                                                                                                                                                                                      Doku Art. Nr. 799000023 

 

 

 

Battery operated

 

ABSOLUTE - Linear encoder and indicator System  

with integrated sensor and magnetic tape guidance

  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                       

Features

 

 

• 

Measuring distances up to 8 meters possible 

• 

Unique definition of the zero point 

(no further referencing necessary) 

• 

Permanent retention of all data and settings 

• 

Reserve energy up to 4 years 

• 

AUTO-POWER-OFF function with adjustable „switch on“ time 

• 

Switch over for absolute / incremental mode  

• 

Millimeters or Inches operation 

• 

Fraction views in the Inch mode possible 

• 

User friendly menu levels 

• 

Completely guided by magnetic tape guidance rail 

• 

Key can be enabled or disabled individually 

• 

Adjustable reference value and 3 tool offsets 

• 

Symbols individually selectable (mm/inches/arrows etc.) 

• 

Costumer specified housing and guidance possible 

 

 

 

Summary of Contents for AZ16I series

Page 1: ...ermanent retention of all data and settings Reserve energy up to 4 years AUTO POWER OFF function with adjustable switch on time Switch over for absolute incremental mode Millimeters or Inches operation Fraction views in the Inch mode possible User friendly menu levels Completely guided by magnetic tape guidance rail Key can be enabled or disabled individually Adjustable reference value and 3 tool ...

Page 2: ...N OPERATION 5 5 1 Initial operation 5 5 1 1 Detection of measuring direction 5 5 1 2 Referencing 5 5 3 Parameter settings 7 6 BATTERY CHANGE 9 7 MAGNETIC TAPE 10 Handling 10 Processing note for sticking 11 Resistance to chemicals of the magnetic tape 11 Sticking and cutting 11 7 TECHNICAL SPECIFICATIONS PRELIMINARY 12 9 TYPE DESIGNATION 13 10 LIABILITY EXCLUSION GUARANTEE 14 ...

Page 3: ...ostumer him self The guideway for the rail is located on the rear of the indicator unit On request the system can be supplied also without guidance and guide rail then the user must provide and guarantee for a suitable mechanical guiding system It must be ensured that the sensor integrated in the indicator keeps the correct distance 0 1 5 mm along the whole measuring distance coplanar to the magne...

Page 4: ...e rail is multipart supplied since for transport technical reasons only a maximum length of 2 m are possible The single rail parts still have no mounting holes These must done by the user and also be fastened align at a suitable place then The magnetic tape must be inserted after arraying the rail parts into the slot of the rails and stuck together with the special sticky tape attached at the magn...

Page 5: ...6I unit shows always the absolute value of the magnetic tape and should be calibrated to the zero point at one time The reference value default setting in reg ister P09 is 0 To assign a zero point to an arbitrary position move to the desired zero point and press the buttons F Set together Reference value Alternatively an arbitrary value can be entered in P09 to set a demanded ref erence measuremen...

Page 6: ...hes back to absolute measurement and the display shows the real absolute value again and ABS also Incr Abs Reference value F Set By pressing F Set together the display sets to the reference value deposited in register P09 Switch back from the sleep mode F The unit switches into the sleep mode after completion of the adjustable time in register P04 if there are no changes in the display value and n...

Page 7: ...using the Incr Abs button F 5 Press F to select the next parameter Repeat No 2 4 for the next parameter F 6 Press F for 3 seconds The display shows the actual value again F 2 Press button F The appropriate parameter value appears in the display 3 sec 3 sec Default settings If during battery insertion the button Incr Abs is pressed the unit sets all registers to the default settings Incr Abs ...

Page 8: ...ve direction disabled Arrow symbol for positive direction enabled 0 1 LCD in standby mode disabled LCD in standby mode enabled Display OFF and battery condition P 03 Decimal place default setting 1 X 0 3 for mm operation only P 05 keyboard interlock default setting 111 X X X 0 1 button Set disabled button Set enabled 0 1 button Incr Abs disabled button Incr Abs enabled 0 1 button disabled button e...

Page 9: ...999 999 Inch 9999 999 Inch P 12 tool offset 3 default setting 30 0 mm 0 300 Inch 999999 9 mm 999999 9 mm 9999 999 Inch 9999 999 Inch P 99 Software version Indicates the software version of the unit 6 Battery change Remove the back wall of the display unit to change the batteries commercial battery type size AA 1 5 V with a standard unit internal battery case All values and settings remains in case...

Page 10: ...ic tape from extreme external magnetic influences To reach a complete adhesion between the several materials a special sticky tape is used Pos 2 Pos 4 Pos 6 Pos 1 Covering band Pos 2 Sticky tape Pos 3 Magnetic rubber tape Pos 4 Sticky tape Pos 5 Steel band Pos 6 Sticky tape Factory bonded Picture 1 Components of the magnetic tape Handling To avoid tension in the magnetic tape don t tuck or twist i...

Page 11: ... proximately 1 year Acetone Gasoline Acetic acid 30 Olein acid Acetylene Steam Acetic acid pure Acetic acid Sea water Ammonia Acetic acid 20 Isopropyl ether Stearic acid 70 C anhydrous Kerosene Strong effects result when contacting permanently the following materials after 1 to 5 months Benzene Nitric acid 70 Turpentine Toluene Lacquer solvent Nitric acid red and Vitriolic Carbon Tetrachloride Tri...

Page 12: ...racter of Measurement Linear no rotative movements possible LCD Display 6 Decades height 8 mm with battery condition signs and symbols Keypad Membrane keypad Operating temperature 5 50 C Stock temperature 0 70 C Humidity Not condensing max 80 Altitude max 2000 m above sea level Protection class IP 43 Outer dimensions W x H 96 x 72 mm Cut out W x H 93 x 67 mm Depth install depth 32 0 mm total depth...

Page 13: ...il for AZ16I Magnetic tape length to order Effective measuring length 100 mm A With effective measuring distances smaller than 1 885 m the guide rail is already assembled with the magnetic tape Please note Owing to the mounting hole the rail is 15 mm s longer B With effective measuring distances larger than 1 885 m several guide rail parts according to the total length and a separately magnetic ta...

Page 14: ...re we keep all rights reserved for any technical modifications without any notice ELGO Electric does not assume any liability for possible errors or mistakes The guarantee period is to two calendar years from the date of delivery and includes the deliv ered unit with all its components ELGO Electric GmbH will at its option replace or repair without charge defects at the unit or the included parts ...