18
Holding register map overview - 2nd part
Section
name
Register
number
Register name
Data
type
Access
control
Stored in
EEPROM
Se
rvic
e
con
fig.
40055 – 40056 Offset trim
float
SP
Y
40057 – 40058 Span trim
float
SP
Y
40059 – 40061 not used
SP
Y
U
se
r
co
nf
ig
.
40062
Modbus slave address
uchar
UP
Y
40063
Group assignment register
uchar
UP
Y
40064
Default operation mode
uchar
UP
Y
40065 – 40066 for internal use, do not change
UP
Y
M
is
c.
40067 – 40068 Password
ulong
N
N
40069 – 40071 not used
N
N
Me
asure
d
va
ria
bles
40072 – 40073 Primary chan. direct readout
float
N
N
40074 – 40075 Auxiliary chan. direct readout
float
N
N
40076 – 40081 not used
N
N
40082
Temperature
uint
N
N
40083
Status register
uint
N
N
40084
not used
N
N
D
at
alo
gg
er
sectio
n
40085
Delay
uint
N
N
40086
Period
uint
N
N
40087
Number of samples
uint
N
N
40088 – 40167 Data memory
uint[80]
N
N
Memory locations marked in column “Stored in EEPROM” as “Y” can be stored into the
transducer’s non-volatile EEPROM memory using Write EEPROM function (see paragraph
4.4.3). The stored configuration is recalled after power-up or using Read EEPROM function
(see paragraph
Chyba! Nenalezen zdroj odkazů.
).
Memory locations marked in column “Access control” as “N” can be read and written with no
restrictions. Memory locations marked as “FP” (Factory password), “SP” (Service password)
and “UP" (User password) can be read without restriction, but can be written only when the
particular section is unlocked using a password. The unlocking procedure is described in
paragraphs
Chyba! Nenalezen zdroj odkazů.
and
Chyba! Nenalezen zdroj odkazů.
.
Summary of Contents for EDT 101
Page 1: ...1 Temperature transducer EDT 101 User manual Rev 6 December 2019...
Page 35: ...35...
Page 40: ...H101AN_201912_EDT101...