background image

15P0056B1

APPLICATION MANUAL     

AMS90/1

  

2/17

TABLE OF CONTENTS

TABLE OF CONTENTS

Standard configuration.............................................................................. Page

2

General features .......................................................................................

"

3

External and fixing dimensions (fig. 1)  .....................................................

"

4

Power and supply connections  ................................................................

"

5

Signal connections ...................................................................................

"

5

Power and supply connections diagram (fig. 2)  .......................................

"

6

Signal connection diagram (fig. 3) ............................................................

"

7

Size codes and extra-quick fuses table ....................................................

"

8

ES719 control board description ...............................................................

"

9

Adjustment trimmers............................................................................

"

9

Signalling LED’s...................................................................................

"

9

Preset jumpers.....................................................................................

"

10

Selection dip-switches .........................................................................

"

10

ES719 control board layout (fig.  4) ..........................................................

"

11

Terminal board description .......................................................................

"

12

Technical data table..................................................................................

"

13

EMI characteristics and input filter  ...........................................................

"

14

Installation, calibration and maintenance  .................................................

"

15

                               

IMPORTANT NOTICE

If, after powering the unit, closing the run contact and sending the speed reference, the motor does
not start, check that the power circuit supply at term. 23-24 has the SAME PHASE of the control
circuit supply at term. 25-26.
If in doubt, with power circuit on (remote control switch closed, if any), check that an alternate
voltage is present with a zero effective value (

±±

 200mV) between terminals 23 and 25, and between

terminals 24 and 26.

STANDARD CONFIGURATION

STANDARD CONFIGURATION

If no custom configuration is required, the standard configuration of the AMS90/1 drive
is the following:

SUPPLY VOLTAGE:

  400Vac / 50Hz.

TACHO GENERATOR FEEDBACK:

  180V

DC

 max.

CURRENT LIMIT:

 rated value.

WARNING

WARNING

:

 before powering the unit on

, check that the voltage (

TR3

J2

) and

frequency (

SW1

) values on the plate match those of the supply mains at terminals 25-

26.

Summary of Contents for AMS90/1 Series

Page 1: ...s no responsibility for the consequences resulting by the use of non original spare parts Elettronica Santerno reserves the right to make any technical changes to this manual and to the device without...

Page 2: ...T NOTICE If after powering the unit closing the run contact and sending the speed reference the motor does not start check that the power circuit supply at term 23 24 has the SAME PHASE of the control...

Page 3: ...h potentiometer Stability Internal or external current limit Armature compensation Acceleration and deceleration ramps Speed offset Light indicators Presence of supply direct voltages Current limit re...

Page 4: ...rtical panel through 4 M4 screws Let a free space in the upper and lower side of the drive so as the cooling air can circulate To access the drive inside unscrew the two self tapping screws 3 5x9 5 us...

Page 5: ...L2 Levelling impedance for form factor enhancement TC Auto transformer if any for D C motor field supply The alternate voltage VEA on the secondary is obtained from the direct voltage VEC through the...

Page 6: ...15P0056B1 APPLICATIONMANUAL AMS90 1 6 17 Connect term 25 26 IN PHASE with term 23 24 respectively Fig 2 Power and supply connections diagram...

Page 7: ...turn connect the earth to cable shield through a connection that should be as short as possible Always fit a NO auxiliary contact of KM remote control switch at terminal 18 as closure of KM remote con...

Page 8: ...r module in case of undesired external short circuits Comply with the max prescribed value for I 2 t The L1 switching impedance is 35A 150 H ELETTRONICA SANTERNO code IM0100354 The current FF form fac...

Page 9: ...rminals 21 22 in case of armature feedback RV7 I LIM Internal current limitation RV8 COMP Compensation for armature drop R x I Note in case of tacho generator feedback keep it in CCW position RV9 n MA...

Page 10: ...reference of 0 10VDC J4 pos I Term 7 configured as ramp input for a current speed reference of 4 20mA current output from term 7 J5 pos I Inner adjustment of current limit J5 pos E External control o...

Page 11: ...AMS90 1 APPLICATIONMANUAL 15P0056B1 11 17 Fig 4 ES719 control board layout n MIN SW1 UP n OUT I LIM n MAX STAB DOWN SW2 COMP n OFS J3 J4 J5 J2 TR3 15V LIM n 0 RUN...

Page 12: ...RV6 up to 10VDC STANDARD calibration 10VDC at max speed 10VDC max 6mA max 12 I OUT Current signal output for possible ammeter STANDARD calibration 10VDC at drive rated current 10VDC max 6mA max 13 10V...

Page 13: ...Hz with presetting by closing the two contacts of dip switch SW1 Note If required 415 440VAC supply voltages are available 10VA 27 28 Single phase supply STANDARD 400VAC max for inner rectifier for fi...

Page 14: ...ctrostatic discharges level 3 EN 61000 4 2 Burst level 3 EN 61000 4 4 Surge level 3 EN 61000 4 5 Radio frequency electromagnetic fields 10V m IEC 1000 4 3 If malfunctions are detected in the devices i...

Page 15: ...fter wiring check if connections and solderings are correct and check the proper positioning of jumpers and dip switches as regards the supply voltage and frequency and the drive application 4 Supply...

Page 16: ...check for data consistency always remembering that the unit sends a 10VDC signal at rated current 10 20 or 30A depending on the circumstances IMPORTANT The last two operations should be performed in t...

Page 17: ...current Note an excessive adjustment may cause instability f Speed offset calibration If with potentiometer at zero speed the motor rotates slowly unless a min reference has been applied to the potent...

Page 18: ...of radio disturbance characteristics of industrial scientific and medical ISM radio frequency equipment EN61000 4 2 Electromagnetic compatibility EMC Part 4 Testing and measurement techniques Section...

Page 19: ...nductor convertors General requirements and line commutated convertors Part 1 3 Transformers and reactors IEC146 6 Semiconductor convertors Part 6 Application guide for the protection of semiconductor...

Page 20: ...CONVERTER OF AMS90 1 TYPE TO WHICH THIS DECLARATION RELATES APPLIED UNDER CONDITIONS SUPPLIED IN THE USER S MANUAL CONFORMS TO THE FOLLOWING STANDARDS OR NORMATIVE DOCUMENTS EN60204 1 Safety of machi...

Reviews: