elero TempoTel 28 260.0001 Operating Instructions Manual Download Page 12

GB-21

GB-22

Programming menu

SETTING 

ENGLISH GB/ ASTRO SHIFT

b

(Language selection, astro shift)

See
previous page

ENGLISH GB

 ASTRO
SHIFT 

b

See
next page

OK

OK

+/–

+/–

You have confirmed the PROG END LIMIT function.
ENGLISH GB appears.

1. You can select the desired language using the 

+/-

buttons.

2. Confirm your language selection by pressing 

OK

. ASTRO SHIFT 

b

appears.

3. The desired astro shift

b

can be set (max. +/- 120 mins.) using the

+/-

buttons.

4. Press 

OK

to confirm.

The ASTRO SHIFT 

b

function is now set.

For further programme settings in the SETTING menu,
see below.

GB

Programming menu

SETTING  

INTERMEDIATE POSITION, VENTILATION/REVERSE, PROG END LIMIT

(Time/position programming)

See
previous page

INTERMEDIATE
POSITITION

VENTILATION
(REVERSE)

PROG1

END LIMIT

OK

PROG1

INTERMEDIATE

POSITION

PROG1

VENTILATION

See
next page

OK

OK

+/–

+/–

+/–

+/–

OK

OK

You have confirmed the HOLIDAY 
function.
INTERMEDIATE POSITION appears.

1. The switching time for the INTERMEDIATE POSITION can be set

using the 

+/-

buttons. The switching time can be set in a few

seconds. Alternatively, you can move the shutter/blind from the
upper end limit into the INTERMEDIATE POSITION using the

DOWN

button.

2. Press 

OK

to confirm. VENTILATION/REVERSE appears.

3. 3. The switching time for the VENTILATION/REVERSE position can

be set using the 

+/-

buttons. The switching time can be set in a

few seconds. Alternatively, you can move the shutter/blind from
the lower end limit into the VENTILATION/REVERSE position using
the 

UP

button. Press 

OK

to confirm.

4. You can choose between PROG END LIMIT, PROG INTERMEDIATE

POSITION and PROG VENTILATION/REVERSE using the 

+/-

buttons.

5. Confirm your selection by pressing 

OK

.

The PROG END LIMIT function is now set.

For further programme settings in the SETTING menu, see below.

Summary of Contents for TempoTel 28 260.0001

Page 1: ...1 Operating instructions Please keep these instructions in a safe place elero GmbH Antriebstechnik Linsenhofer Str 59 63 D 72660 Beuren info elero de www elero com Nr 18 100 4201 0204 GB 309053 Timer...

Page 2: ...tion menu for qualified staff only Expert mode GB 14 Programming radio channels GB 15 Programming transmitters channels GB 15 Programming additional transmitters GB 15 Deleting radio channel settings...

Page 3: ...ns Always observe the following instructions Risk of injury by electric shock For use in dry rooms only Use unmodified elero original parts only Keep persons away from the systems guide track Keep chi...

Page 4: ...nually at any time The TempoTel allows up to 5 receivers to be operated individually or as a group This device is characterised by its user friendly operation Designated use The TempoTel may be used t...

Page 5: ...when a given channel is being used An additional channel is reserved for central command control This is allocated automatically When the central command is active all five LEDs light up NB The label...

Page 6: ...the MAN sliding switch setting only manual command controls are carried out In the AUTO sliding switch setting automatic command controls are carried out e g time astro evening function Operating mod...

Page 7: ...The end limit is the point where the roller shutter blind is in the upper or lower position INTERMEDIATE POSITION The intermediate position is any given position between the upper and lower limits of...

Page 8: ...shutter blind and can be freely selected This function allows you to raise your shutters from the lower end limit until the ventilation slits are open In the case of venetian blinds the slats will be...

Page 9: ...ds after approx 1 second The shutter blind will come briefly to a halt As soon as the shutter begins to move again press the DOWN button on the handheld transmitter The shutter blind will stop The tra...

Page 10: ...to confirm 12 Now set the BLOCKING TIME b for Saturday and Sunday 6 7 using the buttons 13 Press OK to confirm PROGRAMME appears 14 Press the MENU button to switch to operating mode GB Programming me...

Page 11: ...LIDAY OFF HOLIDAY ON OK OK see next page GB Programming menu PROGRAMME ASTRO EVENING UP DOWN command W switching times O O b PROGRAMME INDIVIDUAL SWITCHING Operating mode OK OK OK OK OK OK SWITCHING S...

Page 12: ...ION PROG1 VENTILATION See next page OK OK OK OK You have confirmed the HOLIDAY function INTERMEDIATE POSITION appears 1 The switching time for the INTERMEDIATE POSITION can be set using the buttons Th...

Page 13: ...g OK 3 Press the MENU button to switch to operating mode GB Programming menu SETTING LONDON EXPERT MODE City selection LONGITUDE LATITUDE TIME ZONE LONDON EXPERT MODE ON OFF LONGITUDE LATITUDE TIME Se...

Page 14: ...t use a cleansing agent as this may damage the plastic GB Programming menu FUNCTION MENU The operating element must be removed For experts only ROLLER SHUTTER VENETIAN BLIND INITIAL OPERATION Roller s...

Page 15: ...ge to the receiver Transmission control light is illuminated 2 Transmitter has not 2 Programme the been programmed transmitter into the receiver 3 Wrong group has 3 Select correct been selected group...

Page 16: ...Warnhinweise GB 29 GB 30 GB...