background image

»sonneboy«

"The intelligent weather monitor”

No programming, no adjusting.

Install, connect, ready to go.

GB-14109.55012/0801

Installation and

connection instructions

Summary of Contents for sonneboy

Page 1: ... sonneboy The intelligent weather monitor No programming no adjusting Install connect ready to go GB 14 109 55012 0801 Installation and connection instructions ...

Page 2: ...13 14 Changing light values 13 Changing temperature value 13 14 Changing wind value 13 14 Changing pulse duration 13 14 Changing delay times 13 14 Menu selection 15 Programming protection 15 Programming menus 15 View program 16 Delete program 16 Programming intermediate position turning point 16 Deleting intermediate position turning point 17 Automatic test for light value 17 Troubleshooting 18 2 ...

Page 3: ...Automatic manual mode 6 Unassigned key 7 Display Automatic On Off No Function 8 Display for rain 9 Display for top end position TEP 0 Up Down command key ß Display brightness value exceeded C key in conjunction with DOWN key to set thresholds and times in basic program Display set wind value exceeded Free key programming protection Display for temperature value appears only if temperature control ...

Page 4: ...tor has responded the sunshade system cannot be actuated for at least the set pulse duration 30 sec 3 min The sonneboy has a basic program in which light value temperature wind value pulse duration and delay time are all pre programmed i e the automatic sunshade system can be started without being programmed If you would like to set different values for brightness temperature wind pulse duration o...

Page 5: ...wer Set manual mode using Auto On Off key Manual appears on the display manual mode is set on delivery Using the v or b key check direction of rotation of the motors Important Key v sunshade system must retract Key b sunshade system must extend If the direction of rotation of the motors does not agree with the v and b symbols on the control panel switch off power and change over wires a v and b te...

Page 6: ...een terminals 2 and 3 A second light sensor can be connected between terminals 4 and 6 to increase the angle of incidence No account need be taken of the angle of incidence of the sunlight for connection see Page 8 If it is not possible to connect a second light sensor between terminals 4 and 6 because there are insufficient wires it is also possible to connect the second light sensor in parallel ...

Page 7: ...ro control documentation Note When a temperature level is set the light sensor only becomes active once the set level has been exceeded A second switching point individual switch can be connected for individual operation This is given equal priority to the functions of the UP and DOWN keys on the control panel and is thus also only active in manual mode for connection see Page 8 UP DOWN blue green...

Page 8: ...g a second light sensor to increase angle of incidence Note either a switch or a second light sensor can be connected It is not possible to connect both at once Connecting a rain monitor The rain monitor retracts the system if it rains v White red Mains 230 V 50 Hz v b Switch ...

Page 9: ...e lee of the wind Ensure that no shadows e g from a tower or masts and no reflections fall on the light sensor Connect as per wiring diagram see Page 7 Clip on cover and or unscrew execution Aero Wind monitor Fit wind monitor close to the awning not in the lee of the wind Check correctly positioned see Fig Connect as per wiring diagram see Page 7 Clip on cover Aero ...

Page 10: ...m a tower or masts and no reflections fall on the light sensor Connect as per wiring diagram see Page 7 8 Clip on hood Note functions only in automatic mode Rain monitor Fit rain monitor vertically cable inlet underneath above the sunshade system unprotected Connect as per wiring diagram in cover make contact 4 6 see Page 8 Screw on cover Note functions only in automatic mode ...

Page 11: ...usly Key press Auto On Off HAnd manual and Auto Off symbol appears Function Up press key Stop press key briefly Function Down press key Stop press key briefly 5 2 Automatic mode Key press Auto On Off HAnd manual goes out and Auto On symbol comes on Unless otherwise programmed the sunshade system is controlled in accordance with the set light and wind values any by the rain monitor If the wind valu...

Page 12: ...ogram not temperature controlled Note if shade is to be controlled as a function of temperature select the desired level instead of when programming Wind value level 1 9 adjustable level 1 light breeze level 9 storm Basic program level 3 Attention if the wind value is set too high there is a risk of the sunshade system being destroyed Pulse duration level 00 30 03 00 adjustable level 00 30 30 sec ...

Page 13: ...Repeat programming if necessary 4 Input not confirmed with Enter is considered not entered and the previously entered value is retained 8 Programming If the basic program set at the factory is to be changed the following steps are required Example setting sun extend 7 sun retract 6 temperature 7 wind 2 pulse duration 1 min 30 sec delay time extend 10 min delay time retract 20 min Programming thres...

Page 14: ...d temperature light and wind values appear Programming is complete Programming times Key press Prog 3x flashes Times symbol flashes Key press Enter 1x Display is activated 4 figures set pulse duration flashes Key or to set desired pulse duration Key Enter to confirm pulse duration 2 figures set delay time extend flashes Key or to set desired delay time for extend Key Enter to confirm delay time ex...

Page 15: ...5 Wind value level 4 Light value retract level 4 Delay time extend 5 min Temperature level 6 Delay time retract 15 min 10 Programming menus Key press Prog 1x Menus symbol flashes Key press Enter 1x Display is activated 2 figures 00 flashes last values set Key or set desired menu e g Menu 3 Key Enter to confirm menu Currently measured temperature light and wind values appear Programming is complete...

Page 16: ...nual mode see Page 11 Programming an intermediate position The intermediate position function only possible when straight allows the sunshade system to be positioned in an intermediate position Press Up key and wait for FTP symbol see explanation on FTP Page 17 Press Up key and Down key simultaneously for at least 3 seconds Press Down key until the desired position is reached and then also press t...

Page 17: ...or after an automatic UP v command Depending on the pulse duration set between 30 sec and 3 min 15 Automatic test for light value The automatic test is an installation aid and enables the sun function to be tested quickly The minutes set as the delay time are converted into seconds for this purpose Start automatic test The blind must be pulled right up the control must be on Auto ON and the FTP sy...

Page 18: ...ystem 1 Sunshade system 1 Move sunshade system does not run down is not in top end up and wait until FTP although sun position FTP symbol is displayed symbol is flashing p 17 2 Automatic mode 2 Switch on Automatic not switched on p 11 3 Delay time has not 3 Wait for delay time yet elapsed p 12 4 Set temperature 4 Wait for temperature value not yet reached to rise possibly reduce or switch of tempe...

Page 19: ...19 Notes ...

Page 20: ...20 Notes ...

Page 21: ...21 Notes ...

Page 22: ...elero GmbH Linsenhofer Str 59 63 D 72660 Beuren Germany Tel 49 7025 13 01 Fax 49 7025 13 212 info elero de http www elero de ...

Reviews: