16 | EN
Ⓒ
elero GmbH
Ⓒ
elero GmbH
EN | 17
Important:
Only operate the programming button P using insulated tools
(4 kV voltage protection).
1. Connect the prepared wiring from the wall installation as
shown in the following diagram:
Diagram of the Invio-868
(shown here in combination with the elero AstroTec)
Invio-868
L
In
ProLin
e
L
N
Mains
1
2
3 4 5
6
Single
Central
AstroTec
N L
C
Mains
L
N
Venetian blind switch
230V/50Hz
N
N
L
L
Fig. 3 Connection diagram for the Invio-868 to available
elero
control device components (shown here using the example
of the AstroTec)
2. Carry out the Invio-868/Invio-915 programming procedure at
the receiver (see Section 4.6 “Programming the radio”).
3. Place the Invio-868/Invio-915 in the switch box.
Make sure that the radio antenna is installed as far away from
walls and other objects as possible for an optimum signal.
Do not kink, shorten or extend the antenna.
Do not allow the antenna to rest on metal surfaces.
▼▲
Connection terminals for switches
Connection terminals for
ProLine devices
L
Mains cable
N
Neutral conductor
If reception is poor, adjust the antenna.
Multiple radio systems operating on the same frequency
can lead to reception interferences.
The range of the radio signal may be reduced due to structural
conditions.
4.5.1 Connection terminals for Venetian blind switch
▼ ▲
A Venetian blind switch can be connected to the connection
terminals
③ and ④
(
▼ ▲
).
Special note: Pressing the button for less than 250 ms triggers
the
STOP
function.
4.5.2 Connection terminals for ProLine devices
All potential-free devices can be connected to the connection termi-
nals
⑦ and ⑧
(
). However, only devices in the
elero
ProLine
series can use all the signals.
Important:
The connected ProLine devices must be calibrated as
“drive control devices”.
ProLine safety commands (e.g. from a wind sensor) are not
transmitted as safety commands in ProLine 2. Instead, they
are transmitted as standard commands and are not subject to
any loss monitoring.
The following command (from a connected ProLine control
device or a Venetian blind switch) overrides the existing com-
mand for the duration of the command.
Summary of Contents for Invio-868