3
a
Wall bracket
rotated 90°
Wall bracket
rotated 180°
Mast and corner bracket
(Aero, Aero-915/Aero-915 Plus)
Optional accessory
(Article no. 24 269,0201)
Caution!
Up- or downwinds blowing against façades may
cause destruction of equipment.
The Aero-915/Aero-915 Plus is
not
able to recognise
these.
Please pay attention to this advice when choosing
your mounting position.
Deleting programmed Aero-915/Aero-915 Plus
The Aero-915/Aero-915 Plus is deleted from the receiver.
1.
Press the
UP
/
and the
DOWN
buttons
simul-
taneously
.
10
12
14
2
Off
8
4
6
11
1
3
9
5
7
Green LED
(transmit)
goes out
briefly.
min. 3 sec.
Mounting options for Aero-915/Aero-915 Plus
The wall bracket can be swivelled between –5° and 180°.
Secure the required position once it has been set (see screw a).
Check the sun protection function (test mode)
Condition:
The blind/shutter is retracted.
The delay times are shortened in the test mode. You can then test
the travel movement of your system on the set light value being
exceeded or undercut.
1. Press the
UP
button (wind symbol) for at least 3 seconds until
the green LED flashes.
The test mode stays active for 5 minutes but with the LED
extinguished.
2. Shine a torch on the sun sensor.
Set light value is exceede
W
shutter/blind immediately travels
out/down.
Light value has reached/exceeded the set threshold value
W
yellow LED flashes.
Set light value is undercut
W
shutter/blind travels in/up after
15 seconds.
You can repeat the operation as often as you want within
5 minutes.
In "normal" operation the LEDs light up every 5 seconds and show
that the threshold values have been reached or exceeded.
Warning!
Injury risk from extending the awning or running
down the venetian blind
The test mode is active for 5 minutes. This time
cannot be shortened.
Keep away from the operating range of the system.
Check the wind function (test mode)
Condition:
The blind/shutter is retracted.
The delay times are shortened in the test mode. You can then test
the travel movement of your system on the set wind value being
exceeded or undercut.
During the test phase the set wind value is automatically set to the
lowest value and re-set once the test phase (5 minutes) is over.
1. Press the
UP
button (wind symbol) for at least 3 seconds until
the green LED flashes.
The test mode stays active for 5 minutes but with the LED
extinguished.
2. Use the hand transmitter to bring the shutter/blind to the
centre position.
3. Turn the wind vane.
The shutter/blind travels in/up immediately.
Set wind value is exceeded/undercut
W
red LED flashes.
You can repeat the operation as often as you want within
5 minutes.
Note:
In the event of a wind alarm, the travel keys are disabled for
15 seconds.
In "normal" operation the LEDs light up every 5 seconds and show
that the threshold values have been reached or exceeded.
Warning!
Injury risk from extending the awning or running
down the venetian blind
The test mode is active for 5 minutes. This time
cannot be shortened.
Keep away from the operating range of the system.
Installation
Before installing the unit at the required position, check the
proper function of the Aero-915 and the receiver.