Fault rectification
37
PatioControl
EN
8
Fault rectification
Error/fault
Possible cause
Inspection
Solution
The actuator does not start.
Green LED-1 on the PC board
is OFF.
The power supply is not
connected or the terminals
are reversed.
Check whether the green LED
is flashing or steady.
Connect power supply,
reverse brown and blue if
applicable.
The actuator is connected to
the wrong terminal.
With one actuator is must be
connected to M1.
Connect the actuator to M1
and check the direction of
travel with S4 and S5
(S4 = close, S5 = open).
The actuator does not start
Green LED-1 on the PC board
is ON or flashing.
A programmed Sensero/
Sensero plus is not sending
signals (after 15 min the
pergola moves to wind
protection position and is
blocked.
Check the power supply of
the Sensero.
1. Repair or replace
Sensero.
2. If a Sensero is not
required, delete it from
the control unit.
A wind alarm has tripped.
Check the display on the PC
board (LED-2 flashing red on
the PC board).
Wait for the lock-out time of
15 minutes after
the wind dies down.
There is a short-circuit in the
motor wiring.
Disconnect and check PC
board wiring.
Eliminate the short-circuit.
The actuator moves briefly
and then stops.
The load is too high.
Set the FORCE regulator on
the PC board to a higher
level. Check whether the
pergola may be stiff.
Summary of Contents for 2011781
Page 44: ...42 11 Anhang Bohrmaße Maßstab 1 1 ...
Page 86: ...42 11 Annex Drill hole sizes Scale 1 1 ...
Page 131: ...Annexe 45 PatioControl FR 11 Annexe Cotes de perçage Échelle 1 1 ...
Page 132: ......
Page 176: ...44 11 Appendice Dimensione fori Scala 1 1 ...
Page 221: ...Anexo 45 PatioControl ES 11 Anexo Medida del taladro Escala 1 1 ...
Page 222: ......
Page 223: ......