5. Operation
5-1. Preparation and Caution Before Measurement

1. The function switch should be set to the range to be measured

before operation.
If the function must be switched during a measurement, always
remove the test leads from the circuit being measured.

2. If the unit is used near noise-generating equipment, be aware

that the display may become unstable or indicate large errors.

3. Avoid using the unit in places with rapid temperature variations.
4. In order to prevent damage or injury to the unit, never fail to keep

the maximum tolerable voltage and current, especially for the
10A current range.

5. Carefully inspect the test leads.

If damaged, discard and

replace.

6. In order to avoid wrong range selection, be sure to check the

annunciator on the display.

5-2. Front Panel Description

1. Liquid Crystal Display

2. DC/AC Selector Switch

3. Data Hold Switch

4. Function/Rotary Switch

5. Capacitor Test Socket

6. TR h

FE

Test Socket

7. 10A Input Jack

8. mA Input Jack

9. Common Input Jack

10. V.

W

.Hz Input Jack

11. Holster

12. Peak Hold Switch

-8-

-9-

1

2

4

8

7

5

6

9

10

11

3

12

Summary of Contents for M-2785

Page 1: ...nter Avenue Wheeling IL 60090 847 541 3800 http www elenco com e mail elenco elenco com OPERATOR S INSTRUCTION MANUAL M 2785 WIDE MEASURING DIGITAL MULTIMETER with 15MHz Max Frequency Measurement Copy...

Page 2: ...set it on a flat surface Holding the Test Leads The tilt stand equips the two holes at the center to hold the test leads while you are not doing any measurements Simply set each red black lead in eac...

Page 3: ...features of the meter might be impaired Do not use the meter if the meter or the test leads look damaged or if you suspect that the meter is not operating properly Turn off the power to the circuit u...

Page 4: ...2 digit digital multimeter that is rugged reliable and convenient to use while providing all of the accuracy and features needed for any application It performs DC AC voltage DC AC current resistance...

Page 5: ...enance 12 3 Features 10 Functions 45 Measuring Ranges Surface Mounted PC Board Assembly 1 Basic Accuracy 10MW Input Impedance Large LCD with Function Range Annunciator Full Overload Protection Peak Ho...

Page 6: ...the forward value on the digital display 5 If the digital display reads overrange OL reverse the lead connections The placement of the test leads when the forward reading is displayed indicates the o...

Page 7: ...the COM input jack 2 Set the function rotary switch to the desired W position 3 If the resistance being measured is connected to a circuit turn off the power to the circuit being tested and discharge...

Page 8: ...perature variations 4 In order to prevent damage or injury to the unit never fail to keep the maximum tolerable voltage and current especially for the 10A current range 5 Carefully inspect the test le...

Reviews: