TH232-AF-230

      400-232-003-B                    2010-05-26                    2/4

This thermostat provides the following temperature control modes:

Display

Apply power to the thermostat at the main electrical panel. At

power-up, the thermostat is in manual mode   and displays the
actual (measured) temperature. The setpoint temperature is 28 °C
(82 °F).

LO

The actual temperature is below 0 °C (32 °F).

HI

The actual temperature is above 70 °C (158 °F).

Er

The thermostat built-in sensor is defective. Replace the 
thermostat.

E1

The floor sensor circuit is opened. Check the sensor 
connections.

E2

The floor sensor circuit is shorted. Replace the sensor.

4.1

Control Mode Selection

n

Press and hold the 

Clear

 button for 3 seconds. The current con-

trol mode is displayed 

(

ctl

)

.

o

Press the 

 to select between 

A

AF

 and 

F

.

NOTE: If you have chosen the A or F mode, go to step 7. If you have
chosen the AF mode, the thermostat will control the ambient tempera-
ture while keeping the floor temperature within desired limits. If the
floor temperature is too low or too high, the thermostat will turn heating
on or off to maintain the floor temperature within the limits regardless
of the ambient temperature. The minimum and maximum floor temper-
ature limits are factory-set at 5 °C (41 °F) and 28 °C (82 °F) respec-
tively. To modify the limits, continue with the next step:

p

Press the 

Clear

 button briefly. The minimum limit is displayed (

FL:LO

).

q

Press the 

 button to set the minimum limit.

r

Press the 

Clear

 button briefly. The maximum limit is displayed (

FL:HI

).

s

Press the 

 buttons to set the maximum limit.

t

Press the 

Mode/Return

 button to exit and save the changes.

NOTE: If no button is pressed for 60 seconds, the thermostat will
save the changes and return to normal display.

4.2

Other Configurations

This procedure allows you to choose the following configurations:

n

Press and hold the 

Pgm

 button for 3 seconds. The current tem-

perature unit is displayed (

unit

).

o

Press the 

 to toggle between 

°C

 and 

°F

.

p

Press the 

Pgm

 button briefly. The current time format is dis-

played (

Hr

).

q

Press the 

 to toggle between 

24H

 and 

12H

.

r

Press the 

Pgm

 button briefly. The current Early Start setting is 

displayed (

ES

).

s

Press the 

 to toggle between 

OFF

 and 

On

.

t

Press the 

Mode/Return

 button to exit and save the changes.

n

Description

1.

A mode:

controls and displays the ambient air temperature

F mode:

controls and displays the floor temperature using
an external temperature sensor (default mode)

AF mode:

controls and displays the ambient air temperature

maintains the floor temperature within desired
limits using an external temperature sensor

o

Power Up

2.

p

Error Messages

3.

Day and 
time setting

Schedule 
programming

Mode selection /  
Exit

Clear

Temperature 
adjustment

Temperature 
presets

On/Off button *

* Use this button to disable heating (e.g. in the summer). The
thermostat remains powered and continues to display the time
and temperature.

Time

Day

Temperature

Periods

Heating intensity 
indicator

Automatic mode

Appears when the 
setpoint temperature 
is displayed

Appears when 
heating is disabled

Mode indicator (A, F or AF)

Preset temperature 
indicators

Manual mode

q

q

Configuration

4.

Parameters

Default settings

Temperature format

°C

Time format

24H

Early Start setting (see the note below)

On

TH232-AF-230