2 8
Appendix D
I N S T A L L A T I O N M A N U A L |
Position terminal
dist. (mm)
A*
Directly below an opening, ventilation stone,
casement window etc.
600
B
Above an opening, ventilation stone,
casement window etc.
300
C
In addition to an opening, ventilation stone,
casement window etc.
400
D
Under gutters or drain pipes
300
E
Under eaves
300
F
Under balconies or roofs of open garages
600
G
From a vertical drain pipe
300
H
From an inside or outside corner
600
I
Above ground roof or balcony level
300
J
From a surface opposite the tip
600
K
From an end opposite the tip
600
L
From an opening in the open garage
(e.g. door, window in the house)
1200
M
Vertically from one end to the same wall
1500
N
Horizontally from one end to the same wall
300
P
From a vertical structure on the roof
600
Q
Above the intersection with the roof
150
D
TERMINAL LOCATION
D�A
TERMINAL LOCATION WITH VERTICAL EXHAUST (C11)
Distance
Exhaust 1,2 of 3
At the same roof level
> 6m
*
At a different roof level
> 3m
* & **
On a lower wall
> 2m
*
On a higher sloping surface
> 6m
***
“
Distance
” = minimum distance required to position the exhaust in
order to prevent adverse effects in relation to;
1.
A ventilation opening of a used room, toilet or bathroom
2.
Supply of heated air when the supply flows through a used room.
3.
A window that can be opened and located in the vicinity of a used
room, toilet or bathroom.
*
If the required distance is not feasible, the rules regarding the exit
position have priority.
** If the exhaust is placed at least one meter higher than the inlet
opening, or a window that can be opened.
***
If the required distance is not feasible, the exhaust must be placed at
least one meter above the highest façade / roof.
(4) The terminal may not be placed closer than 300 mm to an opening in
the building such as a window frame.
P
Q
Q
Q
C
D,E
A
B
J
J
F
I
Q
N
M
K
H
H
Figure D.A |
Terminal Location
D�B
TERMINAL LOCATION WITH HORIZONTAL EXHAUST (C31)