background image

I N S TA L L AT I O N   M A N U A L

I N S TA L L AT I O N   M A N U A L

Please leave these instructions behind with the device

M O D O R E -   A N D   T E N O R E   2 4 0

Summary of Contents for Modore 240

Page 1: ...INSTALLATI O N MA NUAL INSTALLATI O N MA NUAL Please leave these instructions behind with the device M O D O R E A N D T E N O R E 2 4 0...

Page 2: ...INSTALLATION MANUAL i Do not use this product as a primary heat source...

Page 3: ...ION 8 6 1 FIRE SAFETY DEVICE SET UP 8 6 1 1 PROTECTION OF WALL AND CEILING 8 6 2 ASSEMBLY REGULATIONS 8 6 2 1 GENERAL ASSEMBLY REGULATIONS 8 6 2 2 ASSEMBLY REGULATIONS FOR NON FLAMMABLE MATERIALS 8 6...

Page 4: ...18 A TROUBLESHOOTER 19 A A FIRST AID FOR MALFUNCTION 19 A B NECESSARY TOOLS 23 B ERRORS CODES PROCONTROL APP 24 B A MESSAGES SHOWN IN APP 24 B B MESSAGES SHOWN IN REMOTE 25 C FAULTS AND ERROR CODES IN...

Page 5: ...evice Make sure it is accessible at all times This device may not be used a primary heat source This device is designed to be used with natural gas or LPG The device can only be used with the type of...

Page 6: ...sembly error or material defect Element4 will provide a free replacement part to the installer without compensation for disassembly or montage 5 In case the installer is not able to fix the problem hi...

Page 7: ...ON 1 2 OFF Figure 3 1 Remote and ignition sign Figure 3 2 Gas Block Figure 3 3 Top and side view of the Receiver 4 2 IGNITING THE PILOT LIGHT Check that the control knob A is in the ON position Figur...

Page 8: ...e in the near vicinity of the device Position the gas connection such that it is always accessible for service purposes The gas block and receiver are under the combustion chamber in the deivce so tha...

Page 9: ...objects e g built in furniture or wooden panels are mountedonthesideofthewallthatisturnedawayfromthefireplace For these types of installations please refer to CHAPTER 6 2 3 CHAPTER 6 2 3 6 2 ASSEMBLY...

Page 10: ...fireplace 200 C Table 6 1 Legenda 6 7 21 6 6 7 21 6 E d3 D F G I d1 H A2 B C d2 Figure 6 4 C31 Flue situation Flammable materials 6 7 21 6 RQ 5 1 339 0 4 81 66 27 5 6 63 0 16 216 5 1 0 0 7 56 685 1 6...

Page 11: ...enclosure ventilation opening are necessary Figure 6 5 The ventilation grills are to be placed at a minimal distance of 20cm from the ceiling and 30cm from any built in furniture from the side any fla...

Page 12: ...radation 7 2 2 REFERENCE THE FLUE CALCULATION In order to ascertain whether your intended extraction shall function properly a stove category is determined After you have determined the applicable cat...

Page 13: ...AL Follow the following instrucions for the installation of flue materials Drill a hole of 160 mm for the wall or roof transit with a 150 mm diameter flue connection and 210 mm with a flue with a diam...

Page 14: ...is to pre set the temperature of you device for a period of one week to ensure yourself of an optimal desired room temperature Also the device can changed between high and low flames and it features a...

Page 15: ...urners and pilot for good condition and operation 10 Replace Grate 11 Replace the Firebed arrangements 12 Replace the access doors 13 Check the flue system and terminal making sure that the terminal v...

Page 16: ...15 Chapter 9 INSTALLATION MANUAL Figure 9 2 Remove side trims Figure 9 3 Remove bottom trim Figure 9 4 Remove glass cords Figure 9 5 Put on suction cup Figure 9 6 Remove side glasses...

Page 17: ...this is the case check the burner pressure at the inlet to the burner The instructions of changing the burner pressure and the correct pressure per gastype can be found in 9 2 2 PILOT The pilot flame...

Page 18: ...t problems Not doing so may cause the fire to explode on ignition 10 DECORATIVE CERAMIC PARTS This appliance is equipped with a ceramic fire bed with heat resistant ceramic fibers or artificial glassy...

Page 19: ...ble plus button to switch between burners Flames and soot During this first fire examine the flame for appearance and quality Flames may appear blue at first but will turn yellow after 15 to 20 minute...

Page 20: ...turbs the reception Change the position of the antenna See Figure A B C No ignition no beep 1 Receiver defective Reset the receiver See K1 If necessary replace the receiver D No ignition receiver give...

Page 21: ...Appendix A INSTALLATION MANUAL Figure A A Bend pin Figure A B Antenna Figure A C Torx screw Figure A D Testpoint 4 5 mV 4 5 mV Figure A E Interrupter Figure A F Wiring receiver 40mm Figure A G Pilot s...

Page 22: ...ouple Position burner grate 3 Airflow in the burner chamber causes a restless fire image Check drain configuration Fit a flue gas limiter I Receiver gives 3 short beeps after each command 1 Batteries...

Page 23: ...Aux position receiver AM PM ON 1 2 OFF Figure A L Double plus button on the remote Figure A M SI port PANEL G60 ZCE 1000 MA GR MO SW 2 1 3 MODE Ignition Main Burner High Flames Pilot Extinguish Main...

Page 24: ...ed Please note If a problem is found that cannot be solved on site always contact your dealer or directly contact Element4 via our credentials which can be found on the back page of this manual 00 00...

Page 25: ...eeps for 3 sec during motor turn Low Receiver battery power supply F10 Contact Service Pilot lit Main burner fails to ignite and pilot shuts off Ignition is blocked for 2 minutes 2nd thermocouple is o...

Page 26: ...mmunication between Receiver and myfire Wi Fi Box F44 Contact Service No temperature shown in App N a not applicable displayed in App Handset not within range Low battery power in handset F49 Contact...

Page 27: ...istances from occurring Many people put the router in the meter cupboard because that is where the internet comes in at many households A bad choice For a powerful WiFi signal the router needs as much...

Page 28: ...NAL LOCATION WITH VERTICAL EXHAUST C11 Distance Exhaust 1 2 of 3 At the same roof level 6m At a different roof level 3m On a lower wall 2m On a higher sloping surface 6m Distance minimum distance requ...

Page 29: ...X X X 2 V V V X X X X 1 5 V V X X X X X 1 V V X X X X X 0 0 5 1 1 5 2 2 5 3 Total Horizontal Section Total vertical Section 23 V X X X X X X 22 V V V X X X X 21 O O V V V X X 20 O O O O 0 V V 19 O O O...

Page 30: ...t 446 0330 24 446 0330 44 Burnerinjection 1200 3X 240 3X Type of flue C11 C31 C91 Additional electricity use At rated heat output elmax 9 5 kW With minimal heat emission elmin 9 5 kW In standby mode e...

Page 31: ...with an eco label which is always supplied with the fireplace The ecolabel shows which category the fireplace belongs to G A ECOLABELS The ecolabels for the different types of gas are indicated below...

Page 32: ...AWINGS On this page you will find trhr dimensional drawings of the Modore and Tenore 240 with some of the important dimensions that you have to take into account when installing and installing your fi...

Page 33: ...32 Appendix H INSTALLATION MANUAL Figure H B Technical drawing of Tenore 240...

Page 34: ...Info element4 nl www element4 nl 19 01 22 ELEMENT 4 B V Design Assembly by RELEASE DATE...

Reviews: