1 4
Chapter 9
I N S T A L L A T I O N M A N U A L |
9
MAINTENANCE INSTRUCTION
This part of the manual focuses on maintenance. To ensure the optimal
flame picture of your device, an annual maintenance by a competent
company or installer is prescribed.
9�1
MAINTENANCE IN THE COMBUSTION CHAMBER
9�1�1
SERVICING
Turn the appliance OFF and isolate the gas supply. Ensure the appliance
is fully cold before attempting to start servicing the appliance. No
liability can be accepted by Element4 for injury caused by burning or
scolding by a hot appliance.
A suggested procedure for servicing is listed below.
1.
Lay out dust sheet on flooring, mask off any special fireplace
materials.
2.
Open Outer Firebox Access Door.
3.
Remove Inner Access Door.
4.
Carefully remove the decorative components (including Embers)
or Gravels
5.
Use a Vacuum cleaner to clean the top of the burners and grate
6.
Remove Grate
7.
Use the vacuum cleaner and a soft brush to clean the pilot
assembly and both Injectors. It may be easier to access the
Injector by removing the Throttle. Never modify or bend the
Thermocouple.
8.
Clean the Window Panel.
9.
Turn on the gas supply and check for leaks, check the burners and
pilot for good condition and operation
10.
Replace Grate
11.
Replace the Firebed arrangements
12.
Replace the access doors.
13.
Check the flue system and terminal, making sure that the terminal
vent is fully clear
14.
Light the appliance and test setting pressures
15.
Check the safe operation of the appliance.
9�1�2
(DIS)ASSEMBLY OF THE TRIMS
For a tight finish of the fireplace, trims are available. During maintenance
these trims must be removed, before the glass can be removed. Please
follow these steps:
Disassembly:
•
Remove both the side trims and bottom trim. They are held by
magnet snappers,
Figure 10.2
&
Figure 10.3
.
Assembly:
•
Put the trims back in reversed order.
9�1�3
REMOVE GLASS
To be able to cleam the glass on the inside, one needs to remove the
glass. To do this follow these steps:
•
Check, whether the trims are removed in as in step 10.1.1.
•
Remove the glass cords. (See
Figure 10.4
)
•
Put the section cup on the glass and make sure it is properly
vaccuumed, so it will not come off. (See
Figure 10.5
)
•
Lift the glass out of the lower glass rail and tilt it out through the
opening, as seen in
Figure 10.6
.
NB
: Put away the glass in a safe place, when you are not using it, to make
sure it will not damage during maintenance. Remove the suction cup
after putting away the glass to avoid tracing or stains.
Figure 9.1 |
Isometric view Modore-/Tenore 240