3 0
Appendix F
I N S T A L L A T I O N M A N U A L |
Gas type »
NATURAL GAS
LPG
Country of use »
AT,BG,CH
DK,ES,FI
GB,GR,HR
IE,IT,LT
LV,NO,PT
RO,SE,SI
SK,TR
DE,LU
PL
BE,FR
DE
NL
BG,DK,EE
FI,GB,GR
HU,HR,IT
LY,MT,NL
NO,RO,SE
SI,SK,TR
CZ,LT
NL,SK
AT,CH
CZ,DE
AT,BE,CH
CZ,DE,ES
FR,GB,IE
IT,NL,PT
SK,TR
Gas Category »
I2
H
I2
E
I2
E+
I2ELL
I2
L
/ I2
EK
I3
B/P
I3
p
I3
P
I3+
Unit
G20
G20
G20/G25
G20/G25
G25/G25,3 G30/G31
G30
G31
G30/G31
Supply pressure
mbar
20
20
20 / 25
20
25
30
50
28 - 30/37
30
Burner pressure
mbar
17,8
17,8
17.8 / 22
17,8
22,0
27,7
27,7
27,7
27,7
Gross input
kW
14,2
14,2
14.2 / 13.2
14,2
13,2
14
14
14
14
Net input
kW
12,8
12,8
12.8 / 11.9
12,8
11,9
12,6
12,6
12,6
12,6
max. Heat output
kW
11,4
11,4
11.4 / 10.6
11,4
10,6
11,2
11,2
11,2
11,2
min. Heat output
kW
2,8
2,8
2.8 / 2.6
2,8
2,6
2,8
2,8
2,8
2,8
(Max.) Gas usage
m
3
/hr
1,33
1,33
1,33/1,43
1,33
1,43
0,51
0,51
0,374
0,51
kg/hr
0,94
0,94
0,94 / 1,06 0,94 / 1,06
1,06
0,93
1,30
0,68
0,93
NOx
mg/kWh
input
<100
<100
Pilot
446,0330,14
446,0330,07
Burnerinjection
1x 280 (Main), 2x 320 (log)
1x 120 (Main), 2x 140 (log)
Type of flue
C11 / C31 / C91
Additional electricity use
•
At rated heat output
el
max
9
-5
kW
•
With minimal heat emission
el
min
9
-5
kW
•
In standby mode
el
sb
9
-5
kW
Power requirement for the permanent pilot light
Power requirement for the permanent pilot
light (requirements applicable)
P
pilot
Does not
apply
Efficiency (NCV)
•
Efficiency at rated heat output
η
th, nom
89 %
•
Efficiency at min. heat output (indicative)
η
th, min
58 %
Type of heat release / control room temperature (Select one)
•
With electronic control of the room temperature plus week switch
Other control options
•
Control of the room temperature with presence detection
•
Control the room temperature with open window detection
•
With the option of remote control
•
With adaptive control of the start
•
With limitation of the operating time
Glass size
•
Front
575 x1001 x 4 mm
•
Side
575 x 325 x 4 mm
F
TECHNICAL DATA
The dataplate specifies for which type of gas, gas pressure and for which
country this appliance is intended. The nameplate is attached to a chain.
It must remain attached to the chain.
Note:
Check whether the appliance is suitable for the gas type and gas
pressure on site.