4 0
Appendix F
I N S T A L L A T I O N M A N U A L |
Gas type »
NATURAL GAS
LPG
Country of use »
AT,BG,CH
DK,ES,FI
GB,GR,HR
IE,IT,LT
LV,NO,PT
RO,SE,SI
SK,TR
DE,LU
PL
BE,FR
DE
NL
BG,DK,EE
FI,GB,GR
HU,HR,IT
LY,MT,NL
NO,RO,SE
SI,SK,TR
CZ,LT
NL,SK
AT,CH
CZ,DE
AT,BE,CH
CZ,DE,ES
FR,GB,IE
IT,NL,PT
SK,TR
Gas Category »
I2
H
I2
E
I2
E+
I2ELL
I2
L
/ I2
EK
I3
B/P
I3
p
I3
P
I3+
Unit
G20
G20
G20/G25
G20/G25
G25/G25,3 G30/G31
G30
G31
G30/G31
Supply pressure
mbar
20
20
20 / 25
20
25
30
50
28 - 30/37
30
Burner pressure
mbar
11,0
11
11 / 11
11,0
11,0
15
15
15
15
Gross input
kW
22,0
22
22 / 21.5
22,0
21,5
23,0
23
23
23
Net input
kW
19,8
19,8
19.8 / 19.3
19,8
19,3
20,7
20,7
20,7
20,7
max. Heat
output
kW
18,2
18,2
18.2 / 17.6
18,2
17,6
18,5
18,5
18,5
18,5
min. Heat output
kW
2,7
2,7
2.7 / 3.5
2,7
3,5
3,7
3,7
3,7
3,7
(Max.) Gas usage
m
3
/hr
2
2
1,84 / 2,0
1,84 / 2,0
2,33
0,62
0,8
0,8
0,61
kg/hr
1,41
1,41
1,41 / 1,72 1,41 / 1,72
1,72
1,13
2,03
1,46
1,12
NOx
mg/kWh
input
21
21
14
17
16
22
22
22
22
Pilot
440-1650-312
440-1350-271
Burnerinjection
2x 360 (Big Log Burners),
2x 280 (Small Log Burner), 1x 360 (FlatBurner)
160 (4x Log Burner ),
140 (FlatBurner)
Type of flue
C11 / C31 / C91
Additional electricity use
•
At rated heat output
el
max
9
-5
kW
•
With minimal heat emission
el
min
9
-5
kW
•
In standby mode
el
sb
9
-5
kW
Power requirement for the permanent pilot light
Power requirement for the permanent pilot
light (requirements applicable)
P
pilot
Does not
apply
Efficiency (NCV)
•
Efficiency at rated heat output
η
th, nom
90 %
•
Efficiency at min. heat output (indicative)
η
th, min
59 %
Type of heat release / control room temperature (Select one)
•
With electronic control of the room temperature plus week switch
Other control options
•
Control of the room temperature with presence detection
•
Control the room temperature with open window detection
•
With the option of remote control
•
With adaptive control of the start
•
With limitation of the operating time
Glass size
•
E4-10 Front
450 x 1400 x 4 mm
Side
450 x 305 x 4 mm
•
E4-11 Front
450 x 1400 x 4 mm
Side
450 x 294 x 4 mm
•
E4-25 Front
450 x 1508 x 4 mm
Side
450 x 294 x 4 mm
Baffle
420 x 285 x 4 mm
F
TECHNICAL DATA
The dataplate specifies for which type of gas, gas pressure and for which
country this appliance is intended. The nameplate is attached to a chain.
It must remain attached to the chain.
Note:
Check whether the appliance is suitable for the gas type and gas
pressure on site.
Summary of Contents for E4-10
Page 2: ...INSTALLATION MANUAL i Do not use this product as a primary heat source ...
Page 44: ...43 Appendix H INSTALLATION MANUAL Figure H B Technical drawing of Summum 140 C ...
Page 45: ...44 Appendix H INSTALLATION MANUAL Figure H C Technical drawing of Summum 140 3S ...
Page 46: ...45 Appendix H INSTALLATION MANUAL Figure H D Technical drawing of Summum 140 RD ...
Page 47: ...46 Appendix H INSTALLATION MANUAL Figure H E Technical drawing of Summum 140 T ...
Page 49: ...Info element4 nl www element4 nl 04 02 22 ELEMENT 4 B V Design Assembly by RELEASE DATE ...